ADTRAN 17101564F1 Quick Start Manual Download Page 5

617101564F1-13A

5

Installing SFP+ Modules

You can install or remove an SFP+ module from an SFP+ port without having to power off the switch. To install an SFP+ module, complete the following 

steps.

1. Insert the module into the appropriate SFP+ port. 
2. Press firmly to ensure that the module seats properly into the connector.

Figure 8. Installing an SFP+ Module into an SFP+ Port

Connecting to the Switch

After the switch is installed and powered, it can be configured by two methods:

■ Web based Graphical User Interface (GUI)
■ Command Line Interface (CLI)

Initial Switch Configuration Using a Web Browser

After powering up the switch for the first time, you can perform the initial switch configuration using a web browser. 

CAUTION!

f

It is recommended that an external AC Surge Protection Device be installed at the AC input connection to the local AC-Powered product. 

The Surge Protection device should provide L-N, L-G, and N-G protection. It is also recommended that the device contains a visual 'GOOD' 

indicator.

WARNING!

f

This equipment incorporates double pole/neutral fusing. If the neutral fuse opens and the line fuse does not open, voltage could still be 

present in the unit.

NOTE

g

This product is intended for use with a Class 1 Laser module that complies with FDA 21 CFR 1040.10, 1040.11 and IEC 60825-1. For 

continued compliance with the above standards, only approved Class 1 laser modules from an ADTRAN approved vendor list (located on 

the ADTRAN website) should be installed in this product. ADTRAN cannot certify system integrity with other laser modules. The CDRH 

Laser Class emitted by the Fiber Optic Laser Module Component is Class I or 1 when installed in the end-product with the fiber-optic cable 

removed.

Summary of Contents for 17101564F1

Page 1: ...efore installing or servicing this equipment NetVanta 1560 24 SYSTEM CONSOLE USB RESET 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 SYS LED CONSOLE Port 10 100 1000 2500 RJ 45...

Page 2: ...them with a screwdriver to secure the brackets Figure 3 Attaching Brackets to the Switch 2 Position the chassis in the stationary equipment rack Allow 1 inch of clearance between units NOTE g Refer t...

Page 3: ...a template install four 8 PAN head screws 0 75 inch using two for each bracket as shown in Figure 6 in the appropriate location on the wall Be aware of the dimensional limitations of the screws 2 Slid...

Page 4: ...equipment and must be easily accessible 3 Confirm that the power is connected properly The SYSTEM LED should be ON see SYSTEM Status LED Figure 7 Connecting the AC Power Cord CAUTION f The NetVanta 15...

Page 5: ...AC Surge Protection Device be installed at the AC input connection to the local AC Powered product The Surge Protection device should provide L N L G and N G protection It is also recommended that th...

Page 6: ...IP address 3 Power up the switch to be initially configured and wait until it has finished its start up processes 4 Connect the PC to any port on the switch using a standard Ethernet cable and check t...

Page 7: ...atus LEDs The Port Status LEDs indicate the current status of each port NOTE g There are many terminal emulation applications available on the web PuTTY SecureCRT and HyperTerminal are a few examples...

Page 8: ...tore to Factory Defaults 7 12 seconds Flashing Green All LEDs are ON Symptoms Possible Causes Suggested Solutions System LED is OFF The switch is not receiving power 1 Check if correct power cord is c...

Page 9: ...g or maintaining always place devices on an approved antistatic mat that is electrically grounded Warranty ADTRAN will replace or repair this product within the warranty period if it does not meet its...

Reviews: