Chapter 3. Operation
3-4
Octal and Quad FXO Modules User Manual
61200310L1-1
M
ENU
Displays additional status and configuration menus for the selected module.
To access the submenus for this item, use the arrow keys to scroll to the
M
ENU
column for the module you want to edit, and press
Enter
. For detailed
information on each submenu item, see the section Octal and Quad FXO Mod-
ules Menu Options on page 3-5.
A
LARM
Read security: 5
Displays an alarm condition on the module. Press
Enter
in this field to acti-
vate the menu.
T
EST
Read security: 5
Displays the test name if the module is executing a test. Press
Enter
in this
field to activate the menu. Tests include
T
EST
2W
,
T
X
ABCD
,
1
K
H
Z
T
ONE
,
and
L
OOPBACK
. See Test on page 3-7 for a description of each test and its
options.
S
TATE
Displays module status as either
O
NLINE
or
O
FFLINE
. Even though a module
is physically installed, it must be marked as online for it to be considered an
available resource. This parameter allows an installed module to be marked
as offline, which may be useful in system troubleshooting. If you choose
O
FFLINE
, the module will not be in alarm condition, but will display
O
FFLINE
.
S
TATUS
This read-only field provides status information on the Octal and Quad FXO
Modules. The following messages may display:
O
NLINE
The module is enabled, and is responding to the system controller’s status
polls. This is the normal response of the system.
N
O
R
ESPONSE
The module is enabled, but is not responding to the system controller’s sta-
tus polls. This response indicates either a problem in the system or that the
module is not installed.
E
MPTY
The system controller has not detected the presence of a module in the slot;
nor has a module been manually enabled for this option slot.
O
FFLINE
The module is installed, but has been taken offline by a user. The module is
still responding to controller polls.
O
FFLINE
/N
O
R
ESPONSE
The module is installed, but has been taken offline by a user. The module is
not responding to polls.
Once a module is installed,
S
TATE
must be set to
O
NLINE
for the
ATLAS 550 to use the module for any data bandwidth.