Hybrid Standalone DVR User Guide
Figure 3-49
9.
Select the desired alarm types: Alarm Out, Show Message, Record Channel, PTZ Activation,
Tour, Snapshot, Buzzer, Voice Prompts, Alarm Upload, or Send Email.
10.
Select the
Save
button to enact the current setup.
Note:
•
There is no Detection Region or Anti-dither setup for Video Masking.
•
Video Masking is only enabled during the time period set. It is disabled for Motion Detection
and Video Loss.
3.5.2
Alarm Setup
1.
In the Main Menu, select
Setting > Event > Alarm
. The alarm setup interface opens.
2.
Click the tab representing the desired alarm type:
•
Local Alarm.
The system detects the alarm signal from the alarm input port.
•
Network Alarm.
The system detects the alarm signal from the network.
•
IPC External Alarm.
The system detects the alarm signal from the front-end device and
activates the local DVR.
•
IPC Offline Alarm.
The system generates an alarm when the front-end IPC disconnects
from the local DVR. The alarm can activate a recording, PTZ, snapshot, etc. The alarm
lasts until the IPC and the DVR resume their connection.
3.
Select the icon
to enable the corresponding function.
4.
Click
Save
when complete.
DVR7800S-U Series Hybrid DVR User Guide