background image

 

 

 

K0022-1 8/01 

6150VADT & 6160VADT 

REMOTE TOUCHPADS 

 

INSTALLATION and OPERATING INSTRUCTIONS 

GENERAL INFORMATION 

The  6150VADT and 6160VADT are addressable remote 
touchpads designed for use with ADT control panels and 
provide the following features:   

• 

Backlit Display 

• 

Programmable Function Keys 

• 

Built-in Sounder 

• 

Voice Chime 

• 

Voice Status 

• 

Message Center 

Notes:  

• 

When used with the Safewatch Pro/Security 
Manager 3000 control panels, address 16 must be 
assigned to a single touchpad.  Additional 
touchpads must be assigned to addresses 17 – 23.  
Refer to Setting The Touchpad Options.   

• 

Touchpad keys are continuously backlit for convenience. 

• 

Permanent display backlighting is an option on some 
controls (refer to the control panel’s instructions for 
details). 

• 

Voice Chime should only be enabled when used with the 
SAFEWATCH PRO/SECURITY MANAGER 3000 (a 
control panel that supports the "chime by zone" mode).  
This mode must be enabled at the control panel.  Refer 
to the control panel's installation and setup guide for 
information on how to program the chime mode.   

PROGRAMMABLE FUNCTION KEYS

 

The Touchpad's programmable function keys [A, B, C, D] are 
programmed for panic alarms by default and correlate to the 
key pairs for panic alarms shown in the table below.  The 
programmable function keys may be programmed to support 
other special functions.  If the programmable functions keys 
are programmed to support other special functions the 
associated touchpad key pairs still provide the respective 
panic alarm (if programmed).  Refer to the control panel’s 
Installation & Setup Guide for details.  

Function 

Keys

 

Equivalent Key Pairs

 

A

 

[1] and [*]

 

B

 

[*] and [#]

 

C

 

[3] and [#]

 

D

 

NONE 

 

 

• 

Function keys must be held down for at 
least 2 seconds to activate the 
programmed function. 
 

• 

If functions other than panics are 
assigned to the programmable function 
keys, programmed panics must be 
initiated by pressing the programmed 
key pair.
 

6160vADT

-50-001-V0

MOUNTING RELEASE SNAPS

(Remove case back by pushing up the 2 "snaps" along

the keypad's bottom edge and pulling the case apart.)

SIDE VIEW

1

2

3

4

5

6

7

8

9

0

#

STAY

BYPASS

CHIME

INSTANT

AWAY

CODE

TEST

OFF

READY

ARMED

READY

MIC

MESSAGE

RECORD

VOLUME

PLAY

STATUS

FUNCTION

VOICE

A

B

C

D

 

 

FUNCTION KEY LABELS

 

A set of adhesive-backed labels with some typical function 
symbols (i.e., fire, police, personal emergency, etc.) is 
provided.  These labels can be placed on or next to the keys 
to identify each key's function for the end user (as 
determined by the capability and programming of the 
control panel; refer to the installation and setup guide for 
the control panel). 

TOUCHPAD DISPLAYS AND LEDS 

The touchpads have the following display features: 

Model 

Fixed 

Word 

Display 

2-Line 

Alpha 

Display 

2-Digit 

Zone 

Identifier 

Custom 

Zone 

Descriptors 

6150VADT X 

 

 

6160VADT  

 

The following table identifies the touchpad’s LEDs and 
associated functions:   

LED Function 

ARMED 

Lights red when the system is armed in any mode. 

READY 

Lights green when the system is "ready" to be armed. 

MESSAGE 

Flashes red when message waiting or lights red 
(steady) when in record mode. 

WIRING AND INSTALLATION 

Touchpads can be surface mounted using drywall anchors or 
to a single- or double-gang electrical box.  

1.  Remove the case back by pushing up the two "snaps" 

along the touchpad’s bottom edge and pulling the case 
apart.  See diagram below. 

2.  Route wiring from the control panel through the 

opening in the case back. 

3.  Mount the case back to a wall or electrical box.  
4.  Wire directly from the touchpad’s terminal block 

to the terminal block on the control board. (See Wiring 
Table below.)  