10.1 Opening and closing the service slot
On devices with a service slot cover, the cover is removed and attached as follows:
Notes:
•
The plastic washers (
turquoise
in the figure) act as a loss-prevention device for the screws.
•
The seal (
green
in the figure) must be inserted levelly into the groove around the edge of the
service slot cover.
Torque for the screws:
M = 2 Nm
The retainer and the cable grommet are removed as described in section 4.4.
ATTENTION
Damage due to electrostatic discharge!
Damage to the device can be caused by electrostatic discharge.
•
Always adhere to the safety measures applicable when handling components at risk of being
damaged by electrostatic discharge.