Advanced RF Technologies, Inc.
30
DO NOT APPLY AC POWER TO THE BDA UNTIL CABLES ARE CONNECTED TO BOTH PORTS OF
THE BDA AND THE ANTENNAS.
-
Prior to equipment use, the d
evice must be registered with the FCC. This can be done through the FCC’s
website at https://signalboosters.fcc.gov/signal-boosters
1.
To mount on a wall, use the appropriate screws and anchors to attach the BDA to the wall using the four
mounting holes with the included wall mount bracket.
2.
Ensure that the isolation between the donor antenna and the serving antennas is at least 15 dB greater
than the BDA gain.
3.
Connect the cable from the donor antenna to the BDA connector labeled “
DONOR
” and
the cable from the
serving antennas to the BDA connector labeled “
SERVER
”.
4.
Wire the AC power source to the AC terminal block inside of the wiring compartment of the BDA and secure
the line using the appropriate conduit and conduit hub connectors.
5.
Power on the repeater by flipping the AC switch to the ON position located on the left side of the PSU.
6.
Installation of the BDA is now complete. Adjust the gain controls to suit the specific signal environment
through the GUI on your PC.
6.
ADRF-BBL/BBS-U INSTALLATION
6.1
Installation Procedures
The ADRF-BBL/BBS-U battery backup unit houses two 12V batteries that are connected in series to have a
nominal voltage of 24VDC. The battery charger is built into the PSU located inside of the PSR-VU-9537-UA.
When the system is being powered by AC, the PSU will charge the ADRF-BBL/BBS-U battery backup. When there
is a loss of primary power (AC), then repeater will switch over to the secondary power (DC) provided by the
battery backup. Once the primary power is restored, the PSR-VU-9537-UBwill switch back to operating with AC
power and will resume charging the battery backup.
1.
Verify that the repeater has been properly grounded.
Summary of Contents for PSR-VU-9537-UA
Page 27: ...Advanced RF Technologies Inc 27 Figure 5 2 PSR ANN Repeater Mount ...
Page 37: ...Advanced RF Technologies Inc 37 7 2 Status Tab Figure 7 3 Status Tab ...
Page 41: ...Advanced RF Technologies Inc 41 7 3 Control Tab Figure 7 9 Control Tab ...
Page 57: ...Advanced RF Technologies Inc 57 Figure 11 2 PSR ANN Annunciator Mechanical Drawing ...
Page 58: ...Advanced RF Technologies Inc 58 Figure 11 3 ADRF BBL U Mechanical Drawing ...
Page 59: ...Advanced RF Technologies Inc 59 Figure 11 4 ADRF BBS U Mechanical Drawing ...