ADRF-BBL/BBS-U INSTALLATION
6.1
Installation Procedures
The ADRF-BBL/BBS-U battery backup unit houses two 12V batteries that are connected in series to have a
nominal voltage of 24VDC. The battery charger is built into the PSU located inside of the PSR-78-9533/9537-U.
When the system is being powered by AC, the PSU will charge the ADRF-BBL/BBS-U battery backup. When
there is a loss of primary power (AC), then repeater will switch over to the secondary power (DC) provided by
the battery backup. Once the primary power is restored, the PSR-78-9533/9537-U will switch back to
operating with AC power and will resume charging the battery backup.
1.
Verify that the repeater has been properly grounded.
2.
Loosen each wheel lock by spinning the red dial to the left.
3.
Move the ADRF-BBL-U-24 to the desired location and spin the red dial to the right to tighten wheel locks.
4.
The brackets on the back of the ADRF-BBL/BBS-U unit can be used to secure to the wall ONLY when it is
stationed on the floor. Due to the total weight of the ADRF-BBL/BBS-U w/ batteries, it CANNOT be wall
mounted off the ground. The brackets are not designed to support the full weight of the ADRF-BBL/BBS-U
when it is wall mounted without any additional support. If a wall mounting solution is needed, then an
optional wall mount kit (ADRF-BBL/BBS-X-WMK) is available for purchase.
Summary of Contents for PSR-78-9533-UA
Page 36: ...Advanced RF Technologies Inc 36 7 2 Status Tab Figure 7 3 Status Tab ...
Page 40: ...Advanced RF Technologies Inc 40 7 3 Control Tab Figure 7 6 Control Tab ...
Page 43: ...Advanced RF Technologies Inc 43 7 4 Install Tab Figure 7 12 Install Tab ...
Page 57: ...Advanced RF Technologies Inc 57 Figure 11 2 PSR ANN Annunciator Mechanical Drawing ...
Page 58: ...Advanced RF Technologies Inc 58 Figure 11 3 ADRF BBL U Mechanical Drawing ...
Page 59: ...Advanced RF Technologies Inc 59 Figure 11 4 ADRF BBS U Mechanical Drawing ...