Advanced RF Technologies, Inc.
25
4.2 External Alarms
The PSR-78-9533-UA supports dry contact alarms and can be connected to a fire alarm control panel. The user can program
the repeater to either create an open or closed circuit when an alarm is present in the system.
4.2.1
External Alarm Output interface
Simplex Alarm Box
Simplex
Digital Board
24V dc
ADRF PSR Repeater
ADRF
Digital Board
Table 4-2
External Alarm
External Alarm Name
Set Condition
Likely Causes
Donor Antenna Malfunction
-
UL Return Power Hard Fail
-
Damaged Donor Antenna
Active RF Device Malfunction
-
RF Power Soft Fail
-
DL Return Power Hard Fail
-
DL/UL Over Power Hard Fail
-
DL/UL Input Overload Hard Fail
-
Degrading Amplifier
-
Open or Disconnected Server Port
-
Oscillation
-
Strong RF Input Signal
Low Battery Capacity (70% depleted)
-
Low Battery Soft Fail
-
Battery Depleted
System Component Malfunction
-
Over Current Hard Fail
-
Over Temperature Hard Fail
-
DSP Hard Fail
-
Out-band Overload Hard Fail
-
Faulty or Damaged PSU
-
Ambient Temperature
-
DSP Filter Fault
-
Strong RF Input Signal
Normal AC Power
-
AC Normal Set
-
AC Fail Soft Clear
-
Powered by AC Power
-
Powered by DC Power
Loss of Normal AC Power
-
AC Fail Soft Set
-
AC Normal Clear
-
Powered by DC Power
-
Powered by AC Power
Battery Charger Failure
-
Battery Fail Soft Fail
-
Battery Not Connected Soft fail
-
Battery Not Charge Soft Fail
-
Low Battery Charging Voltage
-
Battery Cable Disconnected
-
Degraded Batteries
Summary Alarm
-
Any Active Alarm
-
Any Active Alarm Present in the System
Donor Antenna Disconnect
-
No DL Signal Detected
-
Disconnected Donor Line
Oscillation Alarm
-
Oscillation Hard Fail
-
Gain Set Too High or Lack of Isolation
Annunciator Disconnect
-
Annunciator Disconnect Hard Fail
-
Disconnected PSR-ANN
Summary of Contents for PSR-78-9533-UA
Page 36: ...Advanced RF Technologies Inc 36 7 2 Status Tab Figure 7 3 Status Tab ...
Page 40: ...Advanced RF Technologies Inc 40 7 3 Control Tab Figure 7 6 Control Tab ...
Page 43: ...Advanced RF Technologies Inc 43 7 4 Install Tab Figure 7 12 Install Tab ...
Page 57: ...Advanced RF Technologies Inc 57 Figure 11 2 PSR ANN Annunciator Mechanical Drawing ...
Page 58: ...Advanced RF Technologies Inc 58 Figure 11 3 ADRF BBL U Mechanical Drawing ...
Page 59: ...Advanced RF Technologies Inc 59 Figure 11 4 ADRF BBS U Mechanical Drawing ...