background image

1513-MPTB13ME 

Rev. 0 

Pag. 1 di 12 

 

 

 

 

 

INSTRUCTION 

MANUAL

 

 

 

 

 

 

 

 

TB135x 

 

 5 

 

 

 

 

 

 4 

 

 

 

 

 

 3 

 

 

 

 

 

 2 

 

 

 

 

 

 1 

 

 

 

 

 

 0 

Emission 04/11/11 

G. 

Paulitti 

C. 

Laserra 

 

1513.doc 

Rev. 

Subject of the revision 

Date 

Prepared 

Checked  Approved

Summary of Contents for TB135 Series

Page 1: ...1513 MPTB13ME Rev 0 Pag 1 di 12 INSTRUCTION MANUAL TB135x 5 4 3 2 1 0 Emission 04 11 11 G Paulitti C Laserra 1513 doc Rev Subject of the revision Date Prepared Checked Approved ...

Page 2: ... Baud rate selection 5 2 REPEATER OPERATION 6 2 1 Repeater power on 6 2 2 Display indication 6 2 3 Time out 6 2 4 Receiver errors 6 2 5 SERIAL INTERFACE MANAGEMENT 7 3 INSTALLATION 8 3 1 Material receiving 8 3 2 Repeater mounting 8 3 3 Wiring 9 3 3 1 Power supply wiring AC version 9 3 3 2 Serial port connection 10 3 4 Zero input option 11 4 MAINTENANCE 12 4 1 Preventive maintenance 12 4 2 Correcti...

Page 3: ...rd 61010 1 September 1994 SYMBOL DESCRIPTION Alternating current Protective conductor terminal Earth ground terminal Caution refer to accompanying documents Caution risk of electric shock Keep this instruction manual for consultation by all personnel authorized to operate the instrument for as long as the instrument remains in service Additional copies may be ordered from ADOS service centres If a...

Page 4: ...g the equipment to the power source verify that the selected value corresponds to the voltage provided on the label side If the selected value varies from the voltage specified in the license plate it is recommended not to use the equipment and to call the customer service for voltage change 1 6 Technical data Power supply 230 VAC 50 60 Hz 15 10 120 VAC 50 60 Hz optional 15 10 24 VAC 48 VAC option...

Page 5: ...NT C O N F press ENT again to access the configuration parameter or press ESC to cancel B A U D the name of parameter will appear on the display once the required parameter has been identified modification can be made by pressing ENT B A U D 9 6 0 0 the parameter value will appear on the display and the name of the parameter will flash intermittently use the INC and DEC keys to change the paramete...

Page 6: ...e of indications at intervals of about two seconds A D O S R I P N R 1 0 0 Software version B 9 6 0 0 Baud rate 2 2 Display indication 2 3 Time out A two second receiver time out is provided in the repeater the timer is reloaded each time a new character is received When the timer expires the following message will be displayed L I N E flashing 2 4 Receiver errors If the repeater receives no valid...

Page 7: ...5 SERIAL INTERFACE MANAGEMENT The serial line is available in both the RS232 and RS485 mode Selection is made by means of a jumper on CPU Operating parameter of the serial line are 8 bit No Parity 1 Stop 4 RTX485 B RTX485 A SGND 3 2 1 RS232 RS485 RX232 TX232 5 ...

Page 8: ... and to the carrier which delivered the goods The instrument should be delivered with the following 1 copy of the instruction manual 2 copies of the instrument test certificate check that the serial no reported on instrument label corresponds to what is reported on the test certificate 2 cable mounting kits 4 mounting brackets 3 2 Repeater mounting Repeater can be mounted by means of brackets or u...

Page 9: ...NNECTION ERROR VOIDS WARRANTY The connection to the safety ground must always be done For serial line wiring shielded cable is recommended Serial line wiring must be separated from power lines 3 3 1 Power supply wiring AC version CONNECTOR PIN FUNCTION LINE EARTH LINE 1 Line 230 VAC 120 VAC 24 VAC 48VAC LINE 2 Line 230 VAC 120 VAC 24 VAC 48VAC Connect pin to the plant protective earthing system UN...

Page 10: ...st be a maximum of 15 metres long EIA RS 232 C standards or 1000 metres in case of RS485 RS232 In order to create the serial connection use a shielded cable making sure that only one of the two shield ends is grounded If the cable has more conductors than those used connect the free conductors to the shield RS485 In the RS485 modality put a 50 resistor in parallel where necessary to the signal of ...

Page 11: ... are not effects of loss of safety function in case of load limiting systems zero being carried out only locally on the repeater The input is active on the rising and falling edge The closing of contact should be made with voltage free contact The connections to the data connector are modified if compared to the standard version and are showed in the table here below CONNECTOR PIN FUNZIONE DATA 1 ...

Page 12: ...nance For safety reason is a good practice to check periodically by visual inspection the connections to the protective earthling system 4 2 Corrective maintenance Any corrective maintenance to possible failures must be carried out at ADOS laboratories or at least by ADOS authorized personnel EVERY UNAUTHORIZED ACCESS TO THE INSTRUMENT VOIDS WARRANTY ...