XML configuration files reference
Last updated 11/28/2012
MaxDataSampleDescriptions
Located in the
Recording
container.
Each change in codec for a content type has a sample description. For example, two different data encoding formats
each have their own sample description. The server allocates space for sample descriptions when it creates a file. If the
encoding format type changes more than the number of available descriptions, the server stops recording. However,
adding too many descriptions takes up unnecessary space for every file that the server records. The default value is 10.
Note:
This setting applies to recording MP4/F4V files only.
MaxELSTEntries
Located in the
Recording
container.
The maximum number of ELST entries in a recording. The server uses ELST entries when there are gaps in content.
Gaps occur during an append to the file or when video, audio, or data content ends while other such content continues.
If more gaps or appends occur than the value specified in the
MaxELSTEntries
tag, recording ends. However, setting
this value too high takes up unnecessary space in each recorded file. The default value is 100.
Note:
This setting applies to recording MP4/F4V files only.
MaxEventQueueThreads
Located in the
Edge (ResourceLimits)
container.
The maximum number of threads per scheduler queue. The default value is -2.
MaxFailures
The maximum number of login attempts a user can have before having to wait to be allowed again. The wait time is
defined by the
RecoveryTime
element.
The default value is 3. If the number of failed login attempts equals the value of
LockoutLimit
, the admin server must
be restarted before that user can attempt to log in again.
Example
<MaxFailures>3</MaxFailures>
See also
LogInLimits
,
LockoutLimit
,
RecoveryTime
MaxFlushSize
Located in the
RecBuffer
container.
The maximum number of kilobytes to accumulate before flushing the recording buffer. The default value is 256. The
minimum value is 32.
MaxFlushTime
Located in the
RecBuffer
container.
The maximum number of seconds to wait before flushing the recording buffer. The default value is 5. The minimum
value is 1.