ADLINK Technology Inc.
LEC-EL Product specification
Page 14
copyright © 2021 ADLINK Technology Inc.
4.4.5
Power and System Management
Name
Pin #
Description
I/O
Type
I/O
Level
Power
Domain
PU / PD
Comments
BATLOW#
S156
Battery low indication to Module. Carrier to float the
line in inactive state.
I OD
CMOS
1.8V
Runtime
PU 10K
Driven by OD on Carrier.
Pulled up on module.
CARRIER_PWR_ON
S154
Carrier board circuits (apart from power management
and power path circuits) should not be powered up
until the Module asserts the CARRIER_PWR_ON signal.
O
CMOS
1.8Vsb / 1.8V
-
1.8Vsb is only used for signaling, not a power
source to the module
CARRIER_STBY#
S153
The Module shall drive this signal low when the system
is in a standby power state.
O
CMOS
1.8Vsb / 1.8V
-
CHARGER_PRSNT#
S152
Held low by Carrier if DC input for battery charger is
present.
I OD
CMOS
1.8V
Runtime
PU 4.7K
Driven by OD on Carrier.
Pulled up on module.
CHARGING#
S151
Held low by Carrier during battery charging. Carrier to
float the line when charge is complete.
I OD
CMOS
1.8V
Runtime
PU 4.7K
Driven by OD on Carrier.
Pulled up on module.
VIN_PWR_BAD#
S150
Power bad indication from Carrier board. Module and
Carrier power supplies (other than Module and Carrier
power supervisory circuits) shall not be enabled while
this signal is held low by the Carrier.
I OD
CMOS
1.8V
Runtime
PU 2.2K
Driven by OD on Carrier
Module must implement PU but actual value is
depended on particular module design.
SLEEP#
S149
Sleep indicator from Carrier board. May be sourced
from user Sleep button or Carrier logic. Carrier to float
the line in in-active state.Active low, level sensitive.
Should be de-bounced on the Module.
I OD
CMOS
1.8V
Runtime
PU 4.7K
Driven by OD on Carrier.
Pulled up on module.
LID#
S148
Lid open/close indication to Module. Low indicates lid
closure (which system may use to initiate a sleep
state). Carrier to float the line in in-active state. Active
low, level sensitive. Should be de-bounced on the
Module.
I OD
CMOS
1.8V
Runtime
PU 4.7K
Driven by OD on Carrier.
Pulled up on module.
POWER_BTN#
P128
Power-button input from Carrier board. Carrier to float
the line in in-active state. Active low, level sensitive.
Should be debounced on the Module.
I OD
CMOS
1.8V
Runtime
PU 4.7K
Driven by OD on Carrier.
Pulled up on module.
RESET_OUT#
P126
General purpose reset output to Carrier board.
O
CMOS
1.8V
Runtime
RESET_IN#
P127
Reset input from Carrier board. Carrier drives low to
force a Module reset, floats the line otherwise.
I OD
CMOS
1.8V
Runtime
PU 4.7K
Driven by OD on Carrier.
Pulled up on module.
Summary of Contents for SMARC MODULE LEC-EL
Page 1: ...LEC EL L 11 08 2021...
Page 16: ......