104
Integer, ByVal Inverse As Integer) As
Integer
@ Argument
AxisNo
: Axis number designated to move or stop.
Disable
: Disable manual pulse generator input.
Disable = 1, disable manual pulse generator
Disable = 0, enable manual pulse generator
Dist
: Specified relative distance to move (unit: pulse)
For example, if SpeedLimit is set to be 100pps, then the axis
can move at fastest 100pps, even the input manual pulse gen-
erator signal rate is more then 100pps.
DivF
: Divide factor (1-2047)
Note: When 0 or 2048 is entered, the division circuit will be
OFF.
MultiF
: Multiplication factor (0-31)
InputMode
: Setting of manual pulse input mode from the PA and
PB pins
card_id Physical axis AxisNo
0
0
0
1
1
2
2
3
3
1
0
4
1
5
…
…
Value Meaning
0
1X AB phase type pulse input
1
2X AB phase type pulse input
2
4X AB phase type pulse input
3
CW/CCW type pulse input