74
Operation Theory
4.4.4
Positioning Start switch
The positioning start switch is used to move a specific position
when it is turned on. The function is shown as below.
4.4.5
Counter Clear switch
The counter clear switch is an input signal which makes the coun-
ters of motion controller to reset. If users need to reset a counter
according to external command, use this pin as controlling source.
4.4.6
Counter Latch Switch
The counter latch switch is an input singal which makes counter
value to be kept into a register when this input active. If users need
to know counter value at the active moment of one input, they can
connect this pin to catch that.
4.4.7
Emergency Stop Input
Our motion controller provides a global digital input for emergeny
situation. Once the input is turned on, our motion controller will
stop all axes’ motion immediately to prevent machine’s damage.
Ususally, users can connect an emergency stop button to this
input on their machine. We suggest this input as normal closed
type for safty.
Summary of Contents for PCI-8102
Page 10: ...vi List of Figures ...
Page 13: ...Introduction 3 Figure 1 2 Flow Chart for Building an Application ...
Page 18: ...8 Introduction ...
Page 28: ...18 Installation ...
Page 102: ...92 MotionCreatorPro In this menu users can configure LTC SD PCS and Select_Input ...
Page 124: ...114 MotionCreatorPro ...
Page 205: ...Connection Example 195 5 DIN DI_COM 6 DOUT DO_COM 7 DIR OUT DIR OUT ...
Page 206: ...196 Connection Example 8 HSIN 9 HSOUT HO_COM ...
Page 207: ...Connection Example 197 Mechanical Dimensions ...
Page 208: ...198 Connection Example ...
Page 209: ...Appendix 199 Appendix 8 1 Color code of Mitsubishi servo J3A cable MRJ3CN1 xM OPEN ...
Page 210: ...200 Appendix ...