64
Operation Theory
4.2.13
Simultaneous Start Function
Simultaneous motion means more than one axis can be started by
a Simultaneous signal which could be external or internal signals.
For external signal, users must set move parameters first for all
axes then these axes will wait an extern start/stop command to
start or stop. For internal signal, the start command could be from
a software start function. Once it is issued, all axes which are in
waiting synchronous mode will start at the same time.
4.2.14
Speed Override Function
Speed override means that users can change command’s speed
during the operation of motion. The change parameter is a per-
centage of original defined speed. Users can define a 100% speed
value then change the speed by percentage of original speed
when motion is running. If users didn’t define the 100% speed
value. The default 100% speed is the latest motion command’s
maximum speed. This function can be applied on any motion func-
tion. If the running motion is S-curve or bell curve, the speed over-
ride will be a pure s-curve. If the running motion is t-curve, the
speed override will be a t-curve.
Summary of Contents for PCI-8102
Page 10: ...vi List of Figures ...
Page 13: ...Introduction 3 Figure 1 2 Flow Chart for Building an Application ...
Page 18: ...8 Introduction ...
Page 28: ...18 Installation ...
Page 102: ...92 MotionCreatorPro In this menu users can configure LTC SD PCS and Select_Input ...
Page 124: ...114 MotionCreatorPro ...
Page 205: ...Connection Example 195 5 DIN DI_COM 6 DOUT DO_COM 7 DIR OUT DIR OUT ...
Page 206: ...196 Connection Example 8 HSIN 9 HSOUT HO_COM ...
Page 207: ...Connection Example 197 Mechanical Dimensions ...
Page 208: ...198 Connection Example ...
Page 209: ...Appendix 199 Appendix 8 1 Color code of Mitsubishi servo J3A cable MRJ3CN1 xM OPEN ...
Page 210: ...200 Appendix ...