3.2
Digital I/O Connection Example
External devices such as trigger sensors, LED light controllers or
relays can be connected to the NEON-2000-JNX to implement dif-
ferent applications. This section shows an example of how to con-
nect such devices.
Figure 3-2: Digital Input Schematic Diagram
Figure 3-3: Digital Output Schematic Diagram
Camera Side
DI/O GND
VDD
control circuit
Max 5V
DI 0-3
(non-Isolation)
Camera Side
control circuit
OCP/OVP
DO 0-3
(non-Isolation)
load
Max. 100mA
DI/O GND
DC
Max. 30V