Important Safety Instructions

 81

MVP-5100

Important Safety Instructions

For user safety, please read and follow all instructions, Warnings,
Cautions, and Notes marked in this manual and on the associated
device before handling/operating the device, to avoid injury or
damage.

X

Read these safety instructions carefully.

X

Keep the User’s Manual for future reference.

X

Read the Specifications section of this manual for detailed 
information on the recommended operating environment.

X

The device can be operated at an ambient temperature of 
50ºC with DC adapter.

X

It is recommended that the device be installed in Informa-
tion Technology Rooms that are in accordance with Article 
645 of the National Electrical Code and NFPA 75.

X

To avoid electrical shock and/or damage to device:

Z

Keep device away from water or liquid sources.

Z

Keep device away from high heat or humidity.

Z

Keep device properly ventilated (do not block or cover 
ventilation openings).

Z

Always use recommended voltage and power source 
settings.

Z

Always install and operate device near an easily acces-
sible electrical outlet.

Z

Secure the power cord (do not place any object on/over 
the power cord).

Z

Only install/attach and operate device on stable surfaces 
and/or recommended mountings.

Z

The power cord must be connected to a socket or outlet 
with a ground connection.

X

If the device will not be used for long periods of time, turn off 
and unplug from its power source.

X

Never attempt to repair the device, which should only be 
serviced by qualified technical personnel using suitable 
tools.

Summary of Contents for MVP-5100

Page 1: ...NG MVP 5100 Series Value Line 9th Gen Intel Core i7 i5 i3 8th Gen Celeron Processor Embedded Fanless Computer MVP 510A 5101 5102 5103 5104 User s Manual Manual Rev 1 0 Revision Date February 20 2020 P...

Page 2: ...ii Revision History Leading EDGE COMPUTING Revision History Revision Release Date Description of Change s 1 0 2020 02 20 Initial release...

Page 3: ...of the use or inability to use the product or documentation even if advised of the possibility of such damages Environmental Responsibility ADLINK is committed to fulfill its social responsi bility to...

Page 4: ...eir respective companies Conventions Take note of the following conventions used throughout this manual to make sure that users perform certain tasks and instructions properly NOTE NOTE Additional inf...

Page 5: ...es 2 2 Specifications 3 2 1 MVP 510A MVP 5101 3 2 2 MVP 5102 MVP 5103 MVP 5104 5 2 3 MVP 5100 Functional Block Diagram 7 2 4 Display Options 8 2 5 Mechanical Dimensions 9 3 System Layout 11 3 1 Front...

Page 6: ...Chipset 55 B 4 Security 66 B 5 Boot 68 B 6 Save Exit 70 C Appendix Watchdog Timer WDT Function Library 73 C 1 WDT with API Windows 73 C 2 WDT with DOS Linux 76 D Appendix Digital Input Output Functio...

Page 7: ...16 Table 3 6 VGA Connector Pin Definition 17 Table 3 7 Ethernet Port Pin Definition 19 Table 3 8 Active Link LED Indicators 19 Table 3 9 Speed LED Indicators 19 Table 3 10 DC Power Input Pin Definiti...

Page 8: ...viii List of Tables Leading EDGE COMPUTING This page intentionally left blank...

Page 9: ...ector Pin Definition 14 Figure 3 4 Digital Input Circuit 15 Figure 3 5 Digital Output Circuit 15 Figure 3 6 DVI D Connector Pin Definition 16 Figure 3 7 VGA Connector Pin Definition 17 Figure 3 8 Ethe...

Page 10: ...x List of Figures Leading EDGE COMPUTING This page intentionally left blank...

Page 11: ...ant and noise challenges presented by harsh IA environments the elimination of problematic structural elements that negatively affect MTBF greatly increases lifecycle expecta tions for the platform 1...

Page 12: ...etain the shipping carton and packing mate rials for inspection Obtain authorization from your dealer before returning any product to ADLINK Ensure that the following items are included in the package...

Page 13: ...AT i219 supports Intel AMT vPro w C246 Serial Ports COM1 2 RS 232 422 485 COM3 4 RS 232 Optional COM5 6 RS 232 shared w DI O DI O 8 ch DI and 8 ch DO USB 3x USB 3 1 Gen 1 3x USB 2 0 1x internal USB 2...

Page 14: ...airflow 0 6 m s w industrial storage 20 C to 60 C w airflow 0 6 m s w industrial storage Storage Temperature 40 C to 85 C excluding storage devices Humidity approx 95 40 C non condensing Vibration Ope...

Page 15: ...3x Intel GbE 2x i211AT i219 supports Intel AMT vPro w C246 Serial Ports COM1 2 RS 232 422 485 COM3 4 RS 232 Optional COM5 6 RS 232 shared w DI O DI O 8 ch DI and 8 ch DO USB 3x USB 3 1 Gen 1 3x USB 2...

Page 16: ...ature 20 C to 60 C w airflow 0 6 m s w industrial storage Storage Temperature 40 C to 85 C excluding storage devices Humidity approx 95 40 C non condensing Vibration Operating 5 Grms 5 500 Hz 3 axes w...

Page 17: ...CN PCIe Intel LAN I211 RJ45 CN PCIe Intel LAN I211 RJ45 CN M 2 CN 2280 3042 size PCIe x1 or SATA USB 2 USB 3 for H310 PCIe x2 or SATA USB 2 USB 3 for C246 Mini PCIe full size PCIe x1 and USB 2 0 CFast...

Page 18: ...s the MVP 5100 controller can support two H310 or three C246 independent displays with configurations as follows Table 2 1 Maximum Available Resolution Display Configurations Port Resolution Display O...

Page 19: ...Specifications 9 MVP 5100 2 5 Mechanical Dimensions Figure 2 2 MVP 5100 Top View including wall mount brackets units mm 225 238 239 186 240 210 226 A 20 R2 6 R5 5 2 7 2 20...

Page 20: ...10 Specifications Leading EDGE COMPUTING Figure 2 3 MVP 5100 Side View including wall mount brackets Figure 2 4 MVP 5100 Front View including wall mount brackets units mm 240 88 units mm 86 210 88...

Page 21: ...e 3 1 Front Panel I O Table 3 1 Front Panel I O Legend A DC Power Input I Extend Power Button B DisplayPort x2 J Power C DVI D K Reset D VGA L Audio Mic Phones Speaker E USB 2 0 Type A x3 1 2 4 M Digi...

Page 22: ...front panel indicate the following 3 1 3 Reset Button The reset button executes a hard reset for the MVP 5100 LED Indicator Color Description Watchdog WD Yellow Indicates watchdog timer status When wa...

Page 23: ...rt Pin Definition Table 3 3 Applicable Cable Types Pin Signal Pin Signal 1 CN_DDPx0 11 GND 2 GND 12 CN_DDPx3 3 CN_DDPx0 13 CN_DDPx_AUX_SEL 4 CN_DDPx1 14 CN_DDPx_CONFIG2 5 GND 15 CN_DDPx_AUX 6 CN_DDPx1...

Page 24: ...t X Output type Open drain N channel X MOSFET driver with internal pull high of 200 resistance X Source Sink current for all channels 24mA X VOH 2 4 to 5V X VOL 0 to 0 5V Figure 3 3 Digital I O Connec...

Page 25: ...System Layout 15 MVP 5100 Figure 3 4 Digital Input Circuit Figure 3 5 Digital Output Circuit D G N N S 2 2 N D G S 200 2 2...

Page 26: ...3 6 DVI D Connector Pin Definition Table 3 5 DVI D Connector Pin Definition Pin Signal Pin Signal Pin Signal 1 DVIdata 2 10 DVIdata 1 19 GND 2 DVIdata 2 11 GND 20 N C 3 GND 12 N C 21 N C 4 N C 13 N C...

Page 27: ...Figure 3 7 VGA Connector Pin Definition Table 3 6 VGA Connector Pin Definition Pin Signal 1 G_VGA_R 2 G_VGA_G 3 G_VGA_B 4 N C 5 GND 6 GND 7 GND 8 GND 9 N C 10 GND 11 N C 12 CRT_DDAT_CN 13 G_VGA_HSYNC...

Page 28: ...connection on the front panel All USB 3 1 ports are compatible with SuperSpeed Gen2 high speed full speed and low speed USB devices The H310 SKU supports three USB 3 1 Gen1 ports only 3 1 10 Gigabit...

Page 29: ...e Link Yellow Pin 10BASE T 100BASE TX 1000BASE T 1 TX LAN_TX0 2 TX LAN_TX0 3 RX LAN_TX1 4 LAN_TX2 5 LAN_TX2 6 RX LAN_TX1 7 LAN_TX3 8 LAN_TX3 LED Color Status Description Yellow OFF Ethernet port is di...

Page 30: ...up to 2000 m where output meets LPS and SELV circuit requirements Power Source Rating Pin Signal 1 V DC_IN 2 V DGND Voltage Current DC Power Source 12 to 24VDC 12A to 6A min AC to DC Adapter 24VDC 6...

Page 31: ...232 422 485 modes by BIOS setting while COM3 and COM4 support only RS 232 Figure 3 10 COM Port Pin Definition Table 3 11 D Sub 9 pin Signal Function of COM Ports Pin Signal Name RS 232 RS 422 RS 485...

Page 32: ...300MB s are supported The host SATA controller provides a legacy operating mode using I O space and an AHCI operating mode using memory space The CFast card can func tion as a storage device for syste...

Page 33: ...System Layout 23 MVP 5100 3 2 Internal I O Connectors 3 2 1 Mainboard Connector Locations Figure 3 12 Mainboard Connectors A B C D E F G H I J K L M N O P Q R S T U V W...

Page 34: ...SIM for Mini PCIe K Mini PCIe L Wafer for I2C sensor M Wafer for Speaker N Wafer for COM x2 optional DI x8 DO x8 Mic in and Line Out O Wafer for COM x4 P Wafer for I2C sensor Q Internal Power button R...

Page 35: ...ule Power Header Pin Definition 3 2 3 USB 2 0 Connector One USB 2 0 Type A connector is provided on the mainboard for internal USB dongle with another on the backplane board 3 2 4 Mini PCIe Connector...

Page 36: ...2V Fan Connector Pin Definition 3 2 7 Clear CMOS Jumper Upon encountering an abnormal condition preventing the device from booting the jumper can clear the BIOS content stored in CMOS and restore defa...

Page 37: ...RESET Header An internal header is provided for the Power and Reset buttons with pin definition as shown Figure 3 16 PWR RESET Header Pin Definition Table 3 15 PWR RESET Header Pin Definition Pin Sig...

Page 38: ...rier Board One 12V power pin header provides additional AFM MXM carrier board power for an MXM card if used Figure 3 17 12V Power Pin Definition Table 3 16 12V Power Pin Definition Pin Signal Pin Sign...

Page 39: ...Input on page 20 to the inputs of the DC power connector making sure to use the correct input voltage andpolarity WARNING Before providing DC power ensure the voltage and polarity pro vided are compa...

Page 40: ...uded in the Accessory Box to attach the 2 included wall mount brackets to the chassis as indi cated by the red circles below Utilisez les 6 vis M4 6 mm incluses dans la bo te d accessoires pour fixer...

Page 41: ...ording to the spacing dimensions of the holes in the bracket as shown in Figure 2 2 MVP 5100 Top View including wall mount brackets Montez l appareil sur un mur l aide des 4 ouvertures de trou de serr...

Page 42: ...10 drivers for your system from the prod uct page at https www adlinktech com Products Industrial_PCs_ Fanless_Embedded_PCs ExpandableFanlessEmbedded Computers MVP 5100_Series and install The followi...

Page 43: ...opback and an internal hard disk driver is installed Information is presented for reference only Actual power con sumption will vary with different attached devices and operating system Table A 1 Powe...

Page 44: ...m is required to meet these specifications At least 100W at 24V input is recommended X Heat generated by add on PCI PCIe adapters affects thermal stability Additional heat dissipa tion is required whe...

Page 45: ...ships with default settings that work well for most configurations Enter BIOS setup by selecting DEL when the system is powered on the POST Power On Self Test message is displayed The MVP 5100 control...

Page 46: ...rsion System Information Shows current system Project Name CPU Board Version CPU Branding String CPU Stepping GT Info CPU Frequency Total Memory Memory Frequency PCH SKU and Stepping WARNING Changing...

Page 47: ...Time or System Date using the up and down Arrow keys 2 Enter new values using the keyboard and select Enter 3 Select Tab to move between fields NOTE NOTE The date must be entered in MM DD YY format an...

Page 48: ...38 BIOS Setup Leading EDGE COMPUTING B 2 Advanced Accesses advanced options of the MVP 5100 CAUTION Setting incorrect or conflicting values in Advanced BIOS Setup may cause system malfunction...

Page 49: ...ed for Hyper Threading Technology When Disabled only one thread per enabled core is enabled Active Processor Cores Number of cores to enable in each processor package Intel VMX Virtualization Technolo...

Page 50: ...e controlled P states TCC Activation Offset Offset from factory set TCC activation temperature at which the Thermal Control Circuit must be activated TCC will be activated at TCC Activation Temp TCC A...

Page 51: ...ystem to wake on the hr min sec specified DynamicTime sets system to wake ay the current time Increase minute s Ring Wake Enables disables RI ping for Wake On Ring function PCH PME signal PCIe Wake En...

Page 52: ...bles disables SIO COM1 Console Redirection Console Redirection Settings Specify how the host computer and the remote computer in use exchange data Both computers should have the same or compat ible se...

Page 53: ...ta Both computers should have the same or compat ible settings B 2 4 USB Configuration USB Mass Storage Driver Support Enables disables USB mass storage driver support USB transfer time out The time o...

Page 54: ...r where Auto uses default value for Root port 100ms and for Hub port the delay is taken from Hub descriptor B 2 5 TPM 2 0 Configuration Security Device Support Enables disables BIOS support for securi...

Page 55: ...erarchy Enables disables Storage Hierarchy Endorsement Hierarchy Enables disables Endorsement Hierarchy TPM 2 0 UEFI Spec Version Selects TCG2 Spec Version Support Physical Presence Spec Version Direc...

Page 56: ...GE COMPUTING B 2 6 AMT Configuration AMT BIOS Features When disabled AMT BIOS features are no longer supported and user is no longer able to access MEBx Setup MEBx Hotkey Pressed Enables disables auto...

Page 57: ...tion COM1 Control Selects COM1 mode from RS232 RS422 or RS485 COM2 Control Selects COM2 mode from RS232 RS422 or RS485 LAN 1 Intel I219 Enables disables I219 LAN1 LAN 2 Intel I211AT Enables disables I...

Page 58: ...48 BIOS Setup Leading EDGE COMPUTING B 2 8 NCT6106D HW Monitor Displays CPU Board Temperatures System fan speeds and vari ous Voltages...

Page 59: ...BIOS Setup 49 MVP 5100 System Fan Control Mode Configures fan control mode from among Manual Mode Auto Mode and SMART FAN IV Manual Mode Allows configuration of a set fan duty cycle...

Page 60: ...50 BIOS Setup Leading EDGE COMPUTING Auto Mode Fan runs at automatic speed for optimal thermal solution...

Page 61: ...BIOS Setup 51 MVP 5100 SMART FAN IV Four temperatures and four fan duty cycles with three avail able fan speed presets can be user configured...

Page 62: ...Setup Leading EDGE COMPUTING B 2 9 BIOS Watchdog Timer BIOS POST Watchdog Disable disables WatchDog Timer Second Mode enables Watch dog Timer in second mode Minute Mode enables Watchdog Timer in minu...

Page 63: ...BIOS Setup 53 MVP 5100 B 2 10 NVME Configuration Displays NVMe device status...

Page 64: ...54 BIOS Setup Leading EDGE COMPUTING B 2 11 Network Stack Configuration Network Stack Enables disables UEFI Network Stack...

Page 65: ...e 4G Decoding Enables disables 64bit capable devices to be decoded in Above 4G Address Space only when system supports 64 bit PCI Decod ing WARNING Setting incorrect or conflicting values in Chipset B...

Page 66: ...OS Setup Leading EDGE COMPUTING B 3 1 System Agent SA Configuration System Agent SA Configuration Displays and configures VT d capability and provides settings for Memory Graphics and DMI OPI configur...

Page 67: ...BIOS Setup 57 MVP 5100 B 3 1 1 Memory Configuration Memory Configuration Displays memory speed size maker and configuration...

Page 68: ...s Configuration Internal Graphics Keeps IGFX enabled based on Setup options GTT Size Selects GTT Size Aperture Size Selects Aperture Size DVMT Pre Allocated Selects DVMT 5 0 Pre Allocated Fixed Graphi...

Page 69: ...al Gfx Mem Selects DVMT5 0 Total Graphic Memory size used by Internal Graphics Device B 3 1 3 DMI OPI Configuration DMI OPI Configuration Displays DMI link speed and width DMI Max Link Speed Sets DMI...

Page 70: ...60 BIOS Setup Leading EDGE COMPUTING B 3 2 PCH IO Configuration PCH IO Configuration Configures SATA Security and HD Audio...

Page 71: ...d RST Configuration SATA Mode Selection Determines how SATA controller s operate SATA Controller Speed Sets maximum speed the SATA controller can support CFast Card Enables disables CFast Card Hot Plu...

Page 72: ...62 BIOS Setup Leading EDGE COMPUTING SATA HDD 1 Enables disables SATA HDD 1 SATA HDD 2 Enables disables SATA HDD 2...

Page 73: ...BIOS Setup 63 MVP 5100 B 3 2 2 Security Configuration BIOS Lock Enables disables PCH BIOS Lock Enable Required to be enabled to ensure SMM flash protection...

Page 74: ...64 BIOS Setup Leading EDGE COMPUTING B 3 2 3 HD Audio Configuration Audio Output Selection Selects Audio Output...

Page 75: ...BIOS Setup 65 MVP 5100 B 3 2 4 M 2 Device Configuration M 2 Port Device Link Selection Configures M 2 port PCIe Link as X1 or X2...

Page 76: ...is set access is limited and the password requested on Setup If User password is set it acts as a power on password and must be entered to boot or enter setup Administrator Password Sets Administrato...

Page 77: ...the System is in User mode Mode change requires platform reset Secure Boot Mode Selects from Standard or Custom In Custom Secure Boot Policy variables can be configured by a physically present user w...

Page 78: ...ng EDGE COMPUTING B 5 Boot Setup Prompt Timeout Number of seconds before setup activation key is launched with 65535 0xFFFF setting indefinite waiting Bootup Num Lock State Sets keypad Number Lock sta...

Page 79: ...OST and displayed Target Boot Option and click to select the desired device UEFI USB Hard Drive Disk Drives BBS Priorities Specifies Boot Device Priority sequence from available UEFI USB Drives Option...

Page 80: ...and Exit Exits system setup after saving the changes Discard Changes and Exit Exits system setup without saving any changes Save Changes and Reset Resets the system setup after saving changes Discard...

Page 81: ...igned for maximum system stability but less than maximum performance Select Restore Defaults if the computer encounters system configuration problems Save as User Defaults Saves all changes so far as...

Page 82: ...72 BIOS Setup Leading EDGE COMPUTING This page intentionally left blank...

Page 83: ...e generated signal is sent to reset the system C 1 WDT with API Windows The WDT API library files and a demo program incl source code can be downloaded from https www adlinktech com Products Industria...

Page 84: ...the watchdog timer Return codes TRUE if timeout value of watchdog timer is successfully set FALSE if timeout value of watchdog timer is failed to set StartWDT Start the watchdog timer function Once t...

Page 85: ...the initial timeout value specified in SetWDT function ResetWDT or StopWDT should be called before the expiration of the watchdog timer or the system will reset Syntax C C BOOL ResetWDT Parameters No...

Page 86: ...PC IO NCT6102D to enter config mode EnterConfig void outp 0x4E 0x87 outp 0x4E 0x87 Config LPC IO to exit config mode ExitConfig void outp 0x4E 0xAA Read byte from LPC IO register unsigned char r_reg u...

Page 87: ...unit as second w_reg 0xF0 r_reg 0xF0 0x04 start the Watchdog w_reg 0x30 0x01 set timeout value as 30 seconds WDT start automatically while timeout value is set w_reg 0xF1 0x1E printf n printf WDT is...

Page 88: ...78 Watchdog Timer WDT Function Library Leading EDGE COMPUTING printf WDT is disable Program is terminating ExitConfig return 0...

Page 89: ...e DI O function library for MVP 5100 series include the header file awl h and linkage library awl lib in the C project DI O functions are as follows AwlDioGetValue Reads the digital logic state of a d...

Page 90: ...TING Parameter s Index Indexes the digital logic state of MVP 5100 digital input chan nels 1 to 8 bit 0 to 7 Value Sets the digital logic state of MVP 5100 digital output channels 1 to 8 bit 0 to 7 to...

Page 91: ...45 of the National Electrical Code and NFPA 75 X To avoid electrical shock and or damage to device Z Keep device away from water or liquid sources Z Keep device away from high heat or humidity Z Keep...

Page 92: ...nnect the power supply cord before loosening the thumbscrews and always fasten the thumbscrews with a screwdriver before starting the system up X It is recommended that the device be installed only in...

Page 93: ...formation conformes l article 645 du National Electrical Code et la NFPA 75 X Pour viter les chocs lectriques et ou d endommager l appareil Z Tenez l appareil l cart de toute source d eau ou de liq ui...

Page 94: ...ppareil ne fonctionne pas ou ne fonctionne pas selon le manuel de l utilisateur X L appareil est tomb et ou a t endommag et ou pr sente des signes vidents de dommage X D branchez le cordon d alimentat...

Page 95: ...s de S curit Importante 85 MVP 5100 RISQUE DE BR LURES Partie chaude Ne touchez pas cette surface cela pourrait entra ner des blessures Pour viter tout danger laissez la surface refroidir avant de la...

Page 96: ...86 Consignes de S curit Importante Leading EDGE COMPUTING This page intentionally left blank...

Page 97: ...08 360 0200 Toll Free 1 800 966 5200 USA only Fax 1 408 360 0222 Email info adlinktech com ADLINK Technology China Co Ltd 300 Fang Chun Rd Zhangjiang Hi Tech Park Pudong New Area Shanghai 201203 China...

Reviews: