nanoX-BT
Page 19
3.3.3.
DDI0 Channel
Signal
Pin # Description
I/O
PU/PD
Comment
DDI
DDI0_PAIR0-
DDI
DDI0_PAIR1-
DDI
DDI0_PAIR2-
DDI
DDI0_PAIR3-
DDI
DDI0_PAIR4-
DDI
DDI0_PAIR5-
DDI
DDI0_PAIR6-
B71
B72
B73
B74
B75
B76
B81
B82
B77
B78
B91
B92
B93
B94
Digital Display Interface differential pairs
O PCIE
Pair 4 to Pair 6
are not
supported
DDI0_HPD
B89
Digital Display Interface Hot-Plug Detect
I 3.3V
PD
100k
IF DDI0_DDC_AUX_SEL is floating
I/O PCIe
DP AUX+
DDI0_CTRL B98
IF DDI0_DDC_AUX_SEL pulled high
I/O OD 3.3V
HMDI0_CTRLC
LK
IF DDI0_DDC_AUX_SEL is floating
I/O PCIe
DP AUX+
DDI0_CTRLDATA_AUX- B99
IF DDI0_DDC_AUX_SEL pulled high
I/O OD 3.3V
HMDI0_
CTRLDAT
DDI0_DDC_AUX_SEL
B95
Selects the function of DDI1_CTRL and
DDI1_CTRLDATA_AUX-. This pin shall have a 1M pull-down
to logic ground on the Module. If this input is floating the AUX
pair is used for the DP AUX+/- signals. If pulled-high the AUX
pair contains the CRTLCLK and CTRLDATA signals.
I/O OD 3.3V PD 1M
3.3.4.
Gigabit Ethernet
Gigabit Ethernet Pin # Description
I/O
PU/PD
Comment
GB
GBE0_MDI0-
GB
GBE0_MDI1-
GB
GBE0_MDI2-
GB
GBE0_MDI3-
A13
A11
A10
A9
A7
A6
A3
A2
Gigabit Ethernet Controller 0: Media Dependent Interface Differential Pairs
0, 1, 2, 3. The MDI can operate in 1000, 100, and 10Mbit/sec modes.
Some pairs are unused in some modes according to the following:
1000
100
10
MDI[0]+/- B1_DA+/- TX+/-
TX+/-
MDI[1]+/- B1_DB+/- RX+/-
RX+/-
MDI[2]+/- B1_DC+/-
MDI[3]+/- B1_DD+/-
I/O
Analog
Twisted
pair
signals for
external
transformer.
GBE0_ACT#
B2
Gigabit Ethernet Controller 0 activity indicator, active low.
OD
3.3VSB
PD 10k
3.3VSB
GBE0_LINK#
A8
Gigabit Ethernet Controller 0 link indicator, active low.
OD
3.3VSB
GBE0_LINK100#
A4
Gigabit Ethernet Controller 0 100Mbit/sec link indicator, active low.
OD
3.3VSB
GBE0_LINK1000# A5
Gigabit Ethernet Controller 0 1000Mbit/sec link indicator, active low.
OD
3.3VSB
GBE0_CTREF
A14
Reference voltage for Carrier Board Ethernet channel 1 and 2 magnetics
center tap. The reference voltage is determined by the requirements of the
Module PHY and may be as low as 0V and as high as 3.3V. The reference
voltage output shall be current limited on the Module. In the case in which
the reference is shorted to ground, the current shall be 250 mA or less.
GND min
3.3V
max