Motion Control Theory
164
AMP-204C / AMP-208C
4.10.2
Software Protection
The controller provides software protection mechanism of
software limit and postion error protection.
4.10.2.1
Soft-limit Signal
Software limit functions almost the same as that of the hardware
limit with the exception that limit signal is generated by checking
location of each axis with the software limit function. There are the
same plus limit (PEL) and minus limit (MEL) signals. Steps of
using the software limit are described below:
1. Set up position of software limit with axis parameters
PRA_SPEL_POS and PRA_SMEL_POS shown in table
below.
2. Set up stop mode in response to limit signal. You can
select decelerating stop or immediate stop with axis
parameter PRA_EL_MODE (0x02) and PRA_SD_DEC
(0x07).
3. Start up software limit function with axis partameter
PRA_SPEL_EN (0x08) and PRA_SMEL_EN (0x09)
shown in table below.
Please run homing operation to ensure limit position of the
coordiante system before the software limit function can be
started.
After the software limit function is initiated, you may use the
function library provided by the controller to display signal status.
This IO monitoing function is described below:
APS_motion_io_status ();
NO
Define
Description
02h
PRA_EL_MODE
EL signal stop mode
See deceleration rate reference parameter,
PRA_SD_DEC, for deceleration stop mode:
07h
PRA_SD_DEC
Set up rate for deceleration stop
08h
PRA_SPEL_EN
Soft PEL switch
09h
PRA_SMEL_EN
Soft MEL switch
0Ah
PRA_SPEL_POS
Soft PEL position
0Bh
PRA_SMEL_POS
Soft MEL position
Summary of Contents for AMP-204C
Page 8: ...viii Contents ...
Page 12: ...xii List of Figures ...
Page 14: ...xiv List of Tables ...
Page 52: ...38 Getting Start with The Installation ...
Page 71: ...Signal Connection 57 AMP 204C AMP 208C Signal connection diagram ...
Page 72: ...58 Signal Connection Figure 3 13 General purpose digital I O signal connection example ...