Motion Control Theory
116
AMP-204C / AMP-208C
4.7.3
Continuous Interpolation
With continuous interpolation the controller continuously executes
multiple interpolation paths including straight line, arc and helical
interpolations described above. You do continuous interpolation by
giving multipe interpolation commands in sequecne. These
commands shall be saved in buffer of the controller queueing for
execution.
Figure 4-34: Illustration on continuous interplotation (Buffer) movement
For continuous interpolation the only restriction is that the
dimension and axis ID must remain the same. E.g., 3D straight
line must link with 3D arc but not 2D arc and axis to be used must
be the same as well. This controller provides seven setup
methods for speed blending between two adjacent paths.
1. Aborting and blending
2. Aborting forced
3. Aborting stop
4. Buffered
5. Blending when deceleration start
6. Blending when residue-distance met
7. Blending when residue-distance % met
Summary of Contents for AMP-204C
Page 8: ...viii Contents ...
Page 12: ...xii List of Figures ...
Page 14: ...xiv List of Tables ...
Page 52: ...38 Getting Start with The Installation ...
Page 71: ...Signal Connection 57 AMP 204C AMP 208C Signal connection diagram ...
Page 72: ...58 Signal Connection Figure 3 13 General purpose digital I O signal connection example ...