Adley 01POT0806-V1 Manual Download Page 1

01POT0806-V1

01636880514

Base Dimensions

Length = 252cm
Width = 190cm
Height = 214cm 

For Assistance Please 

Contact Customer Care on 

01636 880514

2mm Drill bit

x2

Winter = High Moisture = Expansion

Summer = Low Moisture = Contraction

This building should be erected by 

two people.

For ease of assembly, it is advisable to 

pilot drill all screw holes and ensure 

all screw heads are countersunk.

BEFORE YOU START PLEASE READ INSTRUCTIONS CAREFULLY 

- Check the pack and make sure you have all the parts listed. 

- When you are ready to start, make sure you have the right tools at hand 

(

not supplied) 

including

 

 a Phillips screwdriver, Stanley knife, wood saw, 

step ladder and drill with 2mm bit.

- Ensure there is plenty of space and a clean dry area for assembly. 

TIMBER

As with all natural materials, timber can be affected during various weather 

conditions. For the duration of heavy or extended periods of rain, swelling of the 

wood panels may occur. Warping of the wood may also occur during excessive 

dry spells due to an interior moisture loss. Unfortunately, these processes cannot 

be avoided but can be helped. It is suggested that the outdoor building is 

sprayed with water during extended periods of warm sunshine and sheltered as 

much as possible during rain or snow. 

Our buildings are delivered pre-treated with a water based timber treatment 

however this only helps to protect during transit of your garden item. 

To 

validate your guarantee and for better protection against weathering

 it is 

ESSENTIAL

 that you treat the garden building with a wood preserver within 3 

months of assembly. This will need to be re-applied annually to ensure longevity 

of your building. Care must be taken when constructing the garden building 

that it is not touching the ground and is on a suitable base.

BUILDING A BASE

When thinking about where the building and base is going to be constructed: Ensure that there will be access to all sides for maintenance work and 

annual treatment.

TYPES OF BASE

- Concrete 75mm laid on top of 75mm hard-core.

- Slabs laid on 50mm of sharp sand.

Ensure the base is level and is built on firm ground, to prevent distortion.  Refer to diagrams for the base dimensions,  The base should be slightly 

smaller than the external measurement of the building, i.e. The cladding should overlap the base, creating a run off for water. It is also recommended 

that the floor be at least 25mm above the surrounding ground level to avoid flooding.

Whilst all products manufactured  are made to the highest standards of Safety and in the case of childrens products independently tested to EN71 level, we 
cannot accept responsibility for your safety whilst erecting or using this product.

Please retain product label and instructions for future reference

             

Before assembly  

please make sure you have a 

suitable base ready to erect your 

building 

 

MADE IN GREAT BRITAIN

14/12/10

             

FIXING KIT

Door Panel

1

2

3

4

5

6

7

20

8

9

10

11

12

30

13

14

15

16

17

18

19

Plain Panel x3

Floor Panel 

Side Panel

Side Gable Left & Right

Glazed Roof

Roof Panel x2

Bench

Gable Top Left & Right

Opening Window

Door

Side Panel Trim -1004mm x2

Glazed Roof Fascia -1272mm x2

Bench Support Frame - 958mm

Angled cut cover trim -2046mm x2

Panel Cover Trim - 1793mm x3

Roof Strip- 50x1273mm x2

Fascia - 1340mm x2

Fascia - 70x1273mm x2

Bench Support Frame - 657mm x2

Bench Support Block - 120mm

Window Frame - 650mm

21

22

23

CONTENTS

CONTENTS