Page 1: ...User Manual INNO POCKET ROLL Rev 08 09 2022 ...

Page 2: ...reby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and opera tion of this product Europe Energy Saving Notice En...

Page 3: ...the beams projections Customer Support Contact ADJ Service for any product related service and support needs Also visit forums adj com with questions comments or suggestions Parts To purchase parts online visit http parts adj com US http www adjparts eu EU ADJ SERVICE USA Monday Friday 8 00am to 4 30pm PST Voice 800 322 6337 Fax 323 582 2941 support adj com ADJ SERVICE EUROPE Monday Friday 08 30 t...

Page 4: ...es for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of ADJ Products LLC All products covered by this warranty were manufactured after August 15 2012 and bear identifying marks to that effect ...

Page 5: ...act ADJ customer support for an R A number G E N E R A L I N S T R U C T I O N S To optimize the performance of this product please read these operating instructions carefully and familiarize yourself with the basic operations of this unit These instructions contain important safety information regarding the use and maintenance of this unit Please keep this manual with the unit for future referenc...

Page 6: ...m between this device and a wall Do not attempt to operate this unit if it has been damaged in any way This unit is intended for indoor use only and use of this product outdoors voids all warranties Always mount this unit in safe and stable matter Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attent...

Page 7: ...s The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle Therefore the first fixture controlled by the controller could be the last fixture in the chain When a fixture is assigned a DMX address of 1 the DMX controller kn...

Page 8: ... Connectors Some manufacturers use 5 pin DMX 512 data cables for DATA trans mission in place of 3 pin 5 pin DMX fixtures may be implemented in a 3 pin DMX line by using a cable adaptor These adaptors are readily available at most electric stores The chart below details a proper cable conversion Conductor 5 Pin XLR Male In 3 Pin XLR Female Out Pin 1 Pin 5 Do Not Use Pin 4 Do Not Use Pin 3 Pin 2 Pin...

Page 9: ...A Dimmer Mode Standard StGe Dimmer Mode Stage tv Dimmer Mode TV ArAL Dimmer Mode Architectural thAL Dimmer Mode Theatre bLNd Yes No Activate or deactivate blackout mode LEd On Off Enable or disable the feature that automatically turns off the LED display after 10 seconds on inactivity dISP dISP Display orientation normal dSIP Display orientation inverted PAn Yes No Enable or disable pan inversion ...

Page 10: ...press the UP or DOWN buttons so that PAN is displayed Press ENTER 2 Use the UP and DOWN buttons to make your adjustments and then press ENTER to confirm Press and hold the MENU button for one second to exit GOBO Adjustment of the gobo position 1 Press and hold the ENTER button for at least 5 seconds then press the UP or DOWN buttons so that GOBO is displayed Press ENTER 2 Use the UP and DOWN butto...

Page 11: ... terminator on the last fixture 3 Set the DMX address of the device Refer to the System Menu section of this manual for guid ance 4 You should now be able to control the fixture s DMX traits by using the DMX controller For help with oeprating in DMX mode consult the manual included with your DMX controller Sound Active Mode This mode allows either a single unit or several units linked together to ...

Page 12: ...o Adjust the output intensity using the DIMMER and DIMMER buttons DIMMER and DIMMER Use these buttons to adjust the output intensity or to adjust the strobe speed STROBE Press and hold this button to activate the strobe effect COLOR This button has no defined function for this device 1 9 In Gobo mode Color mode or Show mode these buttons will allow you to select a particular gobo color or show res...

Page 13: ...r to maximize the chances of having a clear path for the wireless signal to reach the device Install the device a minimum of 9 8 ft 3m above audiences and or ground level Arrange the wireless antenna in an upright vertical position Position devices in direct line of sight of the transmitting controller Careful planning and testing of the selected installation location is critical to ensure optimum...

Page 14: ...the last unit in the chain will use the male XLR connector only For longer cable runs we suggest a terminator at the last fixture 2 Set the primary unit to your desired operating mode 3 On the secondary units tap the MENU button until PISD is displayed then press ENTER Choose either SEC1 or SEC2 and press ENTER 4 The secondary units will now follow the primary unit P O W E R C O R D D A I S Y C H ...

Page 15: ...ast Open Slow Close 232 239 Open 240 247 Random Strobe 248 255 Open 4 Color Wheel 000 007 Open 008 014 Gobo 1 Yellow 015 021 Gobo 2 Red 022 028 Gobo 3 Green 029 035 Gobo 4 Blue 036 042 Gobo 5 RGB 043 049 Gobo 6 UV 050 056 Gobo 7 Light Blue 057 063 Gobo 8 UV and Light Blue 064 071 Open Shake 072 078 Gobo 1 Shake 079 085 Gobo 2 Shake 086 092 Gobo 3 Shake 093 099 Gobo 4 Shake 100 106 Gobo 5 Shake 107...

Page 16: ... D M X T R A I T S CHANNEL DMX VALUES FUNCTION 5 000 255 Master Dimmer 0 to 100 6 Dimmer Mode 000 020 Standard 021 040 Stage 041 060 TV 061 080 Architectural 081 100 Theatre 101 255 Default Dimmer Setting ...

Page 17: ... T O M E T R I C C H A R T 1 0 2 0 3 0 4 0 Distance m 0 0m 5 0 Diameter m 0 246 0 491 0 737 0 982 1 228 14 D I M M E R C U R V E C H A R T Fade Time Fade Time Ramp Effect Standard Stage TV Architectural Theatre ...

Page 18: ...ning will ensure longevity and crisp output 1 Use normal glass cleaner and a soft cloth to wipe down the outside casing 2 Use a brush to wipe down the cooling vents and fan grill 3 Clean the external optics with glass cleaner and a soft cloth every 20 days 4 Clean the internal optics with glass cleaner and a soft cloth every 30 60 days 5 Always be sure to dry all parts completely before plugging t...

Page 19: ...fe Secure Position Warranty 2 Years 730 Days Auto Sensing Voltage This fixture contains an automatic voltage switch which will automatically sense the voltage when it is plugged into a power source Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice ADJ Products LLC 6122 S Eastern Ave Los Angeles CA 90040 USA...