NEO FIRE – Technical Manual
38
12.1
Heating circuits basic parameters
Activation of heating circuits
Heating circuits are deactivated in default parametrization (heat demand of the boiler is given by the
parameter 1859 “Flow temp setp cons request”). Adjust the following parameters to enable the heating
circuits and to assign the extension modules to each heating circuit.
12.2
Professional installator parameters
Operating mode
The operating modes of the heating circuits are selected directly in the temperature page.
This setting is used to switch between different operating modes which are:
Automatic
The living zone is operated as per the time switch program
Automatic energy savings functions (e.g. summer/winter mode)
Temporarily 'warmer' or 'cooler' allows the user to temporarily adjust the temperature for special situations
Adjust comfort setpoint
Protective functions active
Protection
The living zone remains protected (frost protection, protection against heat accumulation)
The living zone is switch off
Protective functions active
Automatic summer/winter changeover (ECO functions) and automatic 24-hour heating limit active
Reduced
The living zone is operated continuously at a reduced setpoint
Protective functions active
Automatic summer/winter changeover (ECO functions) and automatic 24-hour heating limit active
Comfort
The living zone is operated continuously at the comfort setpoint
Protective functions active
Automatic summer/winter changeover (ECO functions) and automatic 24-hour heating limit active
Heating curve slope
The heating curve generates the flow temperature setpoint, which is used to maintain a certain flow
temperature level depending on the prevailing weather conditions.
Summary of Contents for NEO FIRE 120
Page 1: ...TECHNICAL MANUAL OF INSTALLATION USE AND MAINTENANCE 07 2020 ...
Page 7: ...NEO FIRE Technical Manual 7 NEO FIRE 360 900 ...
Page 9: ...NEO FIRE Technical Manual 9 NEO FIRE 80 NEO FIRE 120 160 ...
Page 10: ...NEO FIRE Technical Manual 10 NEO FIRE 200 280 NEO FIRE 360 720 ...
Page 34: ...NEO FIRE Technical Manual 34 11 1 Electric drawing NEO FIRE 80 720 ...
Page 35: ...NEO FIRE Technical Manual 35 11 2 Electric drawing NEO FIRE 810 900 ...
Page 37: ...NEO FIRE Technical Manual 37 Electric drawing 1 Boiler with 3 heating circuits ...
Page 41: ...NEO FIRE Technical Manual 41 System drawing 1 Boiler and Domestic Hot Water DHWS ...
Page 58: ...NEO FIRE Technical Manual 58 System drawing D H W and heating circuit 11 11 ...
Page 59: ...NEO FIRE Technical Manual 59 System drawing of an old installation heating circuit 11 ...
Page 70: ...NEO FIRE Technical Manual 70 18 4 Position of probes and sensors ...