ADGT EDM106 User Manual Download Page 14

 

EDM Serial-to-Ethernet Converters 

User Guide ver. 2.0 | 2021-09-01 

 

 

Phone: +420 538 890 720 

14 

E-mail: [email protected] 

5.

 

In the General settings section, you can, if necessary: 

 

set a new password to access the converter settings;  

 

set the time of periodic system reboot of converter (in hours); 

 

reset converter settings to factory values; 

 

specify a white list of IP-addresses.  

Table 7. General settings.

 

Parameter 

Default value 

Possible values 

Password  

adgt 

from 1 to 10 characters 
(Latin letters of different case, numbers) 

System reboot timeout 

24 hours 

from 0 (disabled) to 168 hours (7 days) 
Step - 1 hour. 

Configuring Converter via Console port (RS-232) 

In cases where access to the  converter via Ethernet is not possible, the device can be configured 
through the RS-232 console port (COM-port):  

1.

 

Connect the converter to the  PC using a console cable with a DB-9F  – DB-9M connector. 
Connect one end of the cable to the DB-9F connector of the converter, connect the other end 
to the COM port on the PC. If your computer does not have a COM port, use a COM-USB 
converter. The COM-port number of the connected device can be seen in the section Device 
Manager 

 Ports (COM & LPT)

2.

 

Switch the converter to console mode: press RESET button on the device case and hold it 
pressed for at least 3 seconds. In console mode, RS-232 port operates at speed of 115200 bps. 

3.

 

Open any terminal program on your PC, for example PuTTY. In the connection window, select 
Serial connection, enter the COM-port number of the converter, the port speed (115200
and click Open

4.

 

To access the settings in the console window, enter the password (default – adgt): 

passw adgt 

The responce will be: 

Authorization successful

 — if the password is correct; 

Incorrect password

 — if the password is wrong. 

For a list of commands for reading and changing the parameters, see 

Appendix 1. List of commands 

for configuring the converter through the console port

Fig. 9. Web interface of converter. General settings.

 

Summary of Contents for EDM106

Page 1: ...EDM Serial to Ethernet Converters User Guide...

Page 2: ...es hereinafter referred to as converters The manual contains information about the purpose design technical parameters and operating principles of the converters ADGT systems s r o reserves the right...

Page 3: ...Connector DB 9F of RS 232 interface 7 LED Indication 7 Chapter 2 Operating the converter 9 Connection and installation 9 Configuring EDM Converter 10 Configuring Converter via Web Interface 10 Config...

Page 4: ...r 120 Ohms and PVC tubing Cambrick Converter s features Independent interfaces RS 232 RS 485 RS 422 for connecting industrial devices Connection of up to 256 devices via RS 485 RS 422 interfaces 8 5V...

Page 5: ...n the model EDM106 G Output 8 5V x1 8 5V output for power supply of external devices Load current up to 50 mA Connector terminal block XP2 terminal VO step 3 81 mm PWR x1 Connector RJ 12 power supply...

Page 6: ...ay terminal block A1 Signal A RS 485 1 Output Y of RS 422 line B1 Signal B RS 485 1 Output Z of RS 422 line T T1 G G1 1 Lead of the pluggable terminal resistor 1 connect with output B B1 B to plug in...

Page 7: ...t RX 4 Input DTR 5 Ground 6 Output DSR 7 Input CTS 8 Output RTS 9 Output RING LED Indication The converters have three LED indicators RX data reception TX data transmission ST indication of the connec...

Page 8: ...90 720 8 E mail info adgt cz Table 4 Modes of indication ST RX TX No power Connection standby mode Power connection Resetting the device Factory settings reset ST LED indicator is on for 1 second and...

Page 9: ...parameter are available in section Configuring the converter through the web interface Attention When changing the used Ethernet standard in the network to which the converter is connected for exampl...

Page 10: ...ng Converter via Web Interface Setting up a local connection in Windows 10 After connecting converter to a PC or LAN hub it is necessary to configure the local connection Perform the following steps t...

Page 11: ...255 255 0 Accordingly the IP address in the connection settings must be the same as the address of the converter except for the last digits The last digits can be any from 0 to 254 except 0 and 254 a...

Page 12: ...rk settings and save changes using Submit button Table 5 Network settings Parameter Default value Possible values MAC address Use factory Use factory indicated on the sticker of the case Set manually...

Page 13: ...hite list of IP addresses of clients up to 5 addresses which are allowed to connect the converter when it operates in the Server mode Maximum number of incoming connections 2 2 1 Operation mode TCP cl...

Page 14: ...ect one end of the cable to the DB 9F connector of the converter connect the other end to the COM port on the PC If your computer does not have a COM port use a COM USB converter The COM port number o...

Page 15: ...interrupted by Stop button as well as saved into txt text file by Save to file button Reboot and factory reset Rebooting converter To reboot the device click Restart button in the Home menu Reset to...

Page 16: ...e message File is successfully uploaded Rebooting is in progress appears and you will be automatically redirected to the main page of the web interface Saving and Restoring the Configuration Settings...

Page 17: ...1 Table 8 List of commands for configuring the converter Command Description Note Feature2 help List of available commands R curr_gw Current network gateway R curr_ip Current IP address R curr_mac Cur...

Page 18: ...e Transmit Timeout from 1 to 10000 milliseconds R W rs232_world Data bits 0 8 bit 1 7 bit R W Settings of RS 485 RS 422 interface port 1 rs485_1_auth Authorization type 0 No authorization 1 ADGT autho...

Page 19: ...1 for Server mode The same way for Clients 2 5 R W rs485_2_mode Operation mode 0 Client 1 Server R W rs485_2_parity Parity 1 even 2 odd 0 no check R W rs485_2_port Port number R W rs485_2_remote Inte...

Reviews: