User Manual   

PROFIBUS Master / Ethernet 

 

Document code: MN67575_ENG     Revision 2.011    Page 1 of 34

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

 

                                                                                                                                           

                                                                                                                                         

 

                                                                                                                               

 

                                                                                                                                                        

 

 
 
 
 
 
 
 
 
 
 
                                                                                          
 
 
 
 
 
 
 
 

User Manual 

Revision 2.011 
English 

 

PROFIBUS Master / Ethernet - Converter 

(Order Code: HD67575-A1) 

 

for Website information:  

http://www.adfweb.com/?Product=HD67575

   

 

for Price information: 

http://www.adfweb.com/?Price=HD67575-A1

  

 
 

Benefits and Main Features: 

 

 

Very easy to configure 

 

PROFIBUS up to 6Mbps 

 

Free software for interfacing to the device 

 

Commands available for develop your own 
program 

 

Temperature range: 
-40°C / 85°C  (-40°F / 185°F) 

 

For others PROFIBUS devices, see also the following links:  
 

PROFIBUS Master from/to …

 

www.adfweb.com?Product=HD67570

 

(

… DeviceNet Slave

www.adfweb.com?Product=HD67577

   

(

… CAN

www.adfweb.com?Product=HD67579

  

(

… Modbus TCP Slave

www.adfweb.com?Product=HD67580

  

(

… Modbus Slave

www.adfweb.com?Product=HD67593

  

(

… EtherNet/IP

www.adfweb.com?Product=HD67604

  

(

… PROFINET

 
PROFIBUS Slave from/to …

 

www.adfweb.com?Product=HD67045

 

(

… Serial

www.adfweb.com?Product=HD67053

   

(

… M-Bus Master

www.adfweb.com?Product=HD67252

   

(

… NMEA 2000

www.adfweb.com?Product=HD67551

  

(

… CANopen

www.adfweb.com?Product=HD67552

  

(

… CAN

www.adfweb.com?Product=HD67553

   

(

… J1939

www.adfweb.com?Product=HD67555

 

(

… DeviceNet Master

www.adfweb.com?Product=HD67561

   

(

… Modbus Master

www.adfweb.com?Product=HD67562

   

(

… Modbus Slave

www.adfweb.com?Product=HD67563

   

(

… Ethernet Server

www.adfweb.com?Product=HD67564

   

(

… Modbus TCP Client

www.adfweb.com?Product=HD67565

   

(

… Modbus TCP Server

www.adfweb.com?Product=HD67574

   

(

… DeviceNet Slave

www.adfweb.com?Product=HD67576

   

(

… Ethernet Server

 
Do you need to choose a device? do you want help? 

Ask it to the following link: 

www.adfweb.com?Cmd=helpme

 

 

Summary of Contents for HD67575-A1

Page 1: ...ww adfweb com Product HD67577 CAN www adfweb com Product HD67579 Modbus TCP Slave www adfweb com Product HD67580 Modbus Slave www adfweb com Product HD67593 EtherNet IP www adfweb com Product HD67604...

Page 2: ...thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the docum...

Page 3: ...anical interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the in...

Page 4: ...w adfweb com Phone 39 0438 30 91 31 User Manual PROFIBUS Master Ethernet Document code MN67575_ENG Revision 2 011 Page 4 of 34 EXAMPLE OF CONNECTION Used in pair with the HD67576 A1 allows to make a t...

Page 5: ...om Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFIBUS Master Ethernet Document code MN67575_ENG Revision 2 011 Page 5 of 34 CONNECTION SCHEME Figure 1a Connecti...

Page 6: ...ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFIBUS Master Ethernet Document code MN67575_ENG Revision 2 011 Page 6 of 34 Figure 1b Connection scheme...

Page 7: ...verter allows the following characteristics TCP IP and UDP protocol at Ethernet side Triple isolation between Ethernet PROFIBUS Ethernet Power Supply PROFIBUS Power Supply Mountable on 35mm Rail DIN P...

Page 8: ...aster Ethernet Document code MN67575_ENG Revision 2 011 Page 8 of 34 POWER SUPPLY The device can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin Vmax...

Page 9: ...setting is used for the normal working of the device The second with Dip2 in On position is used for upload the Project Firmware Warning Dip1 of Dip Switch A must be at ON position for working even if...

Page 10: ...t Mode 1 Power green ON Powered OFF Not powered ON Powered OFF Not powered 2 Ethernet comm green Blinks quickly when receive Ethernet commands Blinks quickly Boot state Blinks very slowly 0 5Hz update...

Page 11: ...s quickly Boot state Blinks very slowly 0 5Hz update in progress 2 Device State green Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 PROFIBUS comm green Blin...

Page 12: ...re some codes of cables Belden p n 183079A Continuous Armor DataBus ISA SP 50 PROFIBUS Cable ETHERNET The Ethernet connection must be made using Connector2 of HD67575 A1 with at least a Category 5E ca...

Page 13: ...are works with MSWindows MS 2000 XP Vista Seven 8 32 64bit When launching the SW67575 the right window appears Fig 2 NEW PROJECT OPEN PROJECT The New Project button creates the folder which contains t...

Page 14: ...ROFIBUS side is defined In the field Baud rate the baud rate for the PROFIBUS side is defined The means of the fields for Ethernet are In the field IP ADDRESS insert the IP address In the field SUBNET...

Page 15: ...ing the PROFIBUS Network button from the main window for SW67575 Fig 2 the window PROFIBUS Network Fig 4 appears In this window is possible to Modify the PROFIBUS Master Options Master PROFIBUS Option...

Page 16: ...essing the Master PROFIBUS Options button from the PROFIBUS Network window Fig 4 the PROFIBUS Master Options window appears Fig 5 In this window is possible to set the WatchDog Time for the PROFIBUS S...

Page 17: ...etwork window Fig 4 the PROFIBUS Device window appears Fig 6 In this window is possible to Set the PROFIBUS Slave ID ID Slave PROFIBUS Select the Modules present in the PROFIBUS Slave from the Availab...

Page 18: ...ules Fig 7 point 7 Add a Module from the list of GSD file Fig 7 point 6 Remove a Module from selected list Fig 7 point 5 Add all Modules present in the GSD file Fig 7 point 4 Remove all Modules from s...

Page 19: ...uration of the module in hexadecimal The means of the fields are In the field Description of Module a name of the Module is defined In the field Insert the Configuration of Module HEX the configuratio...

Page 20: ...this option is possible to insert manually the parameters of Device and also of the Modules Using the Modify User Parameters Manually button is possible to insert modify the parametrization of the dev...

Page 21: ...ible to add modify the User and or Modules Parameters manually i e writing the configuration of the parameters in hexadecimal The means of the fields are In the field Insert the number of User Paramet...

Page 22: ...the Module selected Parameters of module Fig 11 point 2 The Configuration of all parameters in RAW for the Module selected Parameters in RAW Hex Fig 11 point 3 The admited value for the selected param...

Page 23: ...ent code MN67575_ENG Revision 2 011 Page 23 of 34 CAPABILITIES The section Capabilities is used only to show which features baudrates available in the PROFIBUS device The Green Icon indicate that capa...

Page 24: ...lities section to check it In the field Enable Freeze the PROFIBUS Freeze command is enable This option is enable only if the Freeze Mode is supported by the device see Capabilities section to check i...

Page 25: ...on Insert the IP 192 168 2 205 Turn on the device Press the Ping button must appear Device Found Press the Next button Select which operations you want to do Press the Execute update firmware button t...

Page 26: ...ce automatically goes at Normal Mode At this point the configuration firmware on the device is correctly update Note When you install a new version of the software it is better if the first time you d...

Page 27: ...m download filefold SW67575 Tool zip The manual of this software can be found here www adfweb com download filefold MNSW67575 Tool_ENG pdf STANDARD MODE The request include the following byte Byte Num...

Page 28: ...it7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 If all is correct you have to read 0x0F Example1 Request to get data from address PROFIBUS 21 without writing nothing Request 15 00 00 Response 03 15 00 0F BA 27...

Page 29: ...00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00...

Page 30: ...n 4 4 n 1 Data Write n Number of Byte to Write If the Number of Byte to Write n has got the value 0x00 there are no data to write The response includes the following byte Byte Number Description Abbr...

Page 31: ...ata from address PROFIBUS 21 without writing nothing Extended Mode Request 95 00 00 Response 03 15 00 0E BA 27 28 45 65 71 00 00 00 00 00 00 00 00 6B 04 00 00 1A 00 00 00 00 00 A1 11 00 00 00 00 00 00...

Page 32: ...Ethernet Document code MN67575_ENG Revision 2 011 Page 32 of 34 MECHANICAL DIMENSIONS ORDER CODE Order Code HD67575 A1 PROFIBUS Master Ethernet Converter ACCESSORIES Order Code AC34001 Rail DIN Power...

Page 33: ...ropean countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an ap...

Page 34: ...h to exchange or repair it please do the following 1 Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information a...

Reviews: