ADF Web HD67E19-A1 User Manual Download Page 1

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

EtherCAT / NMEA 2000

 

 

Document code: MN67E19_ENG     Revision 1.000   Page 1 of 26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

Revision 1.000 
English

 

 

EtherCAT / NMEA 2000 - Converter

  

(Order Code:  HD67E19-A1) 

 

For Website information:  

www.adfweb.com?Product=HD67E19

      

 

For Price information: 

www.adfweb.com?Price=HD67E19-A1

 

 
 

Benefits and Main Features: 

 

Very easy to configure 

 

Triple Electrical isolation 

 

Temperature range: -40°C/+85°C (-40°F/+185°F) 

 

For other EtherCAT Slave products see also the following link: 

 

Converter EtherCAT Slave to  

www.adfweb.com?Product=HD67E00

       

(Serial) 

www.adfweb.com?Product=HD67E01

      

(Modbus Master) 

www.adfweb.com?Product=HD67E02

      

(Modbus Slave) 

www.adfweb.com?Product=HD67E03

       

(Modbus TCP Master) 

www.adfweb.com?Product=HD67E04

       

(Modbus TCP Slave) 

www.adfweb.com?Product=HD67E05

       

(BACnet Master) 

www.adfweb.com?Product=HD67E06

       

(BACnet Slave) 

www.adfweb.com?Product=HD67E07

       

(CAN) 

www.adfweb.com?Product=HD67E08

       

(CANopen) 

www.adfweb.com?Product=HD67E09

       

(DeviceNet Master) 

www.adfweb.com?Product=HD67E10

       

(DeviceNet Slave) 

www.adfweb.com?Product=HD67E11

       

(DMX) 

www.adfweb.com?Product=HD67E12

        

(Ethernet) 

www.adfweb.com?Product=HD67E14

        

(IEC61850 Master) 

www.adfweb.com?Product=HD67E15

        

(IEC61850 Slave) 

www.adfweb.com?Product=HD67E16

       

(J1939) 

www.adfweb.com?Product=HD67E17

       

(MQTT) 

www.adfweb.com?Product=HD67E18

       

(NMEA0183) 

www.adfweb.com?Product=HD67E20

     

(OPC UA Client) 

www.adfweb.com?Product=HD67E21

       

(OPC UA Server) 

www.adfweb.com?Product=HD67E22

       

(PROFINET Master) 

www.adfweb.com?Product=HD67E23

       

(PROFINET Slave) 

www.adfweb.com?Product=HD67E24

       

(SNMP Manager) 

www.adfweb.com?Product=HD67E25

       

(SNMP Agent) 

www.adfweb.com?Product=HD67E26

       

(EtherNet/IP Master) 

www.adfweb.com?Product=HD67E27

       

(EtherNet/IP Slave) 

www.adfweb.com?Product=HD67E28

       

(S7comm Client) 

www.adfweb.com?Product=HD67879

       

(IO-Link Master) 

User Manual   

 

Summary of Contents for HD67E19-A1

Page 1: ...7E05 BACnet Master www adfweb com Product HD67E06 BACnet Slave www adfweb com Product HD67E07 CAN www adfweb com Product HD67E08 CANopen www adfweb com Product HD67E09 DeviceNet Master www adfweb com...

Page 2: ...S 25 WARRANTIES AND TECHNICAL SUPPORT 26 RETURN POLICY 26 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Up...

Page 3: ...ice can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation o...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT NMEA 2000 Document code MN67E19_ENG Revision 1 000 Page 4 of 26 EXAMPLE OF CONNECTION...

Page 5: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT NMEA 2000 Document code MN67E19_ENG Revision 1 000 Page 5 of 26 CONNECTION SCHEME Figure 1 Connection scheme for HD67E19 A1...

Page 6: ...tween EtherCAT bus and NMEA 2000 bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor SW67E1...

Page 7: ...9_ENG Revision 1 000 Page 7 of 26 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at...

Page 8: ...he position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used for...

Page 9: ...00 comm green It blinks when NMEA 2000 communication is running Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 4 Error state green ON An error in the communication busses occurs...

Page 10: ...andard Ethernet packet or frame according to IEEE 802 3 is no longer received interpreted and copied as process data at every node The EtherCAT slave devices read the data addressed to them while the...

Page 11: ...ng of the converter must be made using Connector9 and or Connector10 of the HD67E19 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform...

Page 12: ...ns with Windows called SW67E19 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on ou...

Page 13: ...iguration A device s configuration can also be imported or exported To clone the configurations of a programmable EtherCAT NMEA 2000 Converter in order to configure another device in the same manner i...

Page 14: ...language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to c...

Page 15: ...EtherCAT NMEA 2000 Document code MN67E19_ENG Revision 1 000 Page 15 of 26 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside the...

Page 16: ...the fields for NMEA 2000 are In the field Baudrate the data rate of J1939 is defined In the field TimeOut Data a time is defined When a NMEA2000 message is not received in this time the data on OPC UA...

Page 17: ...therCAT Master Master To Slave SLAVE TO MASTER The means of the fields are If the field Enable is checked the EtherCAT variable is enabled In the field Type the data format of the EtherCAT variable is...

Page 18: ...is enabled In the field Type the data format of the EtherCAT variable is defined In the field Lenght the dimension of the EtherCAT variable is defined In the field Name the name of the EtherCAT varia...

Page 19: ...s checked the frame can use transport protocol functions If the field Fast Packet is checked the frame will use the Fast Packet functions In the field Start Byte the starting byte to save internal mem...

Page 20: ...field Fast Packet is checked the frame will use the Fast Packet functions In the field Num Byte the number of bytes of the NMEA 2000 message is defined If the field On Request is checked the NMEA 200...

Page 21: ...t cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 of D...

Page 22: ...ogram inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program mor...

Page 23: ...strial Electronic Devices ADFweb com S r l User Manual EtherCAT NMEA 2000 Document code MN67E19_ENG Revision 1 000 Page 23 of 26 MECHANICAL DIMENSIONS Figure 9 Mechanical dimensions scheme for HD67E19...

Page 24: ...d combination of the following HD67E19 xx Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67E19 EtherCAT NMEA 2000 Converter Order Code HD67E1...

Page 25: ...n systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycl...

Page 26: ...the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to th...