background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l.           

User Manual   

LoRaWAN / J1939 

 

Document code: MN67D26_ENG     Revision 1.000   Page 1 of 30

 

 

 

 

 

 

lorawan 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

Revision 1.000 
English 

 

LoRaWAN / J1939 - Converter 

 (Order Code:  HD67D26-B2-868MHz 

 
 

For Website information:  

www.adfweb.com?Product=HD67D26-B2

  

 

For Price information: 

www.adfweb.com?Price=HD67D26-B2-868MHz

 

 

 

Benefits and Main Features: 

 

Very easy to configure 

 

Power Supply 18…35V DC and 8…24 V AC 

 

Temperature range: -40°C/+85°C  (-40°F/+185°F) 

 

For others LoRaWAN products, see also the following links: 

 

Converter LoRaWAN to  

www.adfweb.com?Product=HD67D01

        

(LoRaWAN)

 

www.adfweb.com?Product=HD67D02

        

(LoRaWAN) 

www.adfweb.com?Product=HD67D03

      

(Modbus TCP Master) 

www.adfweb.com?Product=HD67D04

      

(Modbus TCP Slave) 

www.adfweb.com?Product=HD67D05

      

(Serial) 

www.adfweb.com?Product=HD67D15

      

(M-Bus) 

www.adfweb.com?Product=HD67D16

      

(BACnet Master) 

www.adfweb.com?Product=HD67D17

       

(BACnet Slave) 

www.adfweb.com?Product=HD67D18

       

(Ethernet)

 

www.adfweb.com?Product=HD67D19

       

(CAN) 

www.adfweb.com?Product=HD67D20

      

(CANopen) 

www.adfweb.com?Product=HD67D21

      

(DeviceNet Master) 

www.adfweb.com?Product=HD67D22

      

(DeviceNet Slave) 

www.adfweb.com?Product=HD67D23

      

(DMX) 

www.adfweb.com?Product=HD67D24

      

(EtherNet/IP Master) 

www.adfweb.com?Product=HD67D25

      

(EtherNet/IP Slave) 

www.adfweb.com?Product=HD67D27

      

(KNX) 

www.adfweb.com?Product=HD67D28

      

(NMEA 0183) 

www.adfweb.com?Product=HD67D29

      

(NMEA 2000) 

www.adfweb.com?Product=HD67D30

      

(PROFIBUS Master) 

www.adfweb.com?Product=HD67D31

      

(PROFIBUS Slave) 

www.adfweb.com?Product=HD67D32

      

(PROFINET Master) 

www.adfweb.com?Product=HD67D33

      

(PROFINET Slave) 

www.adfweb.com?Product=HD67D34

      

(IEC61850 Client) 

www.adfweb.com?Product=HD67D35

      

(IEC61850 Server) 

www.adfweb.com?Product=HD67D36

      

(MQTT) 

www.adfweb.com?Product=HD67D37

      

(OPC UA Client) 

www.adfweb.com?Product=HD67D38

      

(OPC UA Server) 

www.adfweb.com?Product=HD67D39

      

(S7comm) 

www.adfweb.com?Product=HD67D40

      

(SNMP Manager) 

www.adfweb.com?Product=HD67D41

      

(SNMP Agent) 

 

User Manual   

 

Summary of Contents for HD67D26-B2

Page 1: ...w adfweb com Product HD67D17 BACnet Slave www adfweb com Product HD67D18 Ethernet www adfweb com Product HD67D19 CAN www adfweb com Product HD67D20 CANopen www adfweb com Product HD67D21 DeviceNet Mas...

Page 2: ...ND TECHNICAL SUPPORT 30 RETURN POLICY 30 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to...

Page 3: ...can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of t...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual LoRaWAN J1939 Document code MN67D26_ENG Revision 1 000 Page 4 of 30 EXAMPLE OF CONNECTION...

Page 5: ...Industrial Electronic Devices ADFweb com S r l User Manual LoRaWAN J1939 Document code MN67D26_ENG Revision 1 000 Page 5 of 30 CONNECTION SCHEME Figure 1 Connection scheme for HD67D26 B2 xxxMHz...

Page 6: ...ormation between LoRaWAN bus and J1939 bus Mountable on 35mm Rail DIN Wide power supply input range 12 35V DC and 8 24V AC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor...

Page 7: ...vision 1 000 Page 7 of 30 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at 24V DC D...

Page 8: ...position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used for u...

Page 9: ...en Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 J1939 communication yellow Blinks when a J1939 message is received Blinks quickly Boot state Blinks very sl...

Page 10: ...stars topology in which gateways relay messages between end devices and a central network server The wireless communication takes advantage of the Long Range characteristics of the LoRa physical laye...

Page 11: ...r terminating the CAN line with a 120 resistor it is necessary that the Dip1 of Dip Switch B is at ON position Cable characteristics DC parameter Impedance 70 Ohm m AC parameters Impedance 120 Ohm m D...

Page 12: ...thernet connection must be made using Connector2 of HD67D26 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relat...

Page 13: ...erter use the available software that runs with Windows called SW67D26 It is downloadable on the site www adfweb com and its operation is described in this document The software works with MS Windows...

Page 14: ...iguration A device s configuration can also be imported or exported To clone the configurations of a Programmable LoRaWAN J1939 Converter in order to configure another device in the same manner it is...

Page 15: ...anguage of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to che...

Page 16: ...l LoRaWAN J1939 Document code MN67D26_ENG Revision 1 000 Page 16 of 30 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside the ta...

Page 17: ...ine the fundamental communication parameters of two buses LoRaWAN and J1939 By Pressing the Set Communication button from the main window for SW67D26 Fig 2 the window Set Communication appears Fig 3 T...

Page 18: ...unication is defined In the field Max Payload Size the maximum dimension of the LoRaWAN messages is defined fixed in relation to the data rate selected In the field Activation Method the method used t...

Page 19: ...he J1939 messages received In the field ID Device J1939 the ID of J1939 side of the converter is defined ETHERNET This section is used to define the general parameters of Ethernet The means of the fie...

Page 20: ...ta to J1939 LORAWAN UPLINK The means of the fields are If the field Enable is checked the LoRaWAN message is enabled In the field Start Byte the starting byte of the internal memory array where taking...

Page 21: ...OWNLINK The means of the fields are If the field Enable is checked the LoRaWAN message is enabled In the field Start Byte the starting byte of the internal memory array where placing the data is defin...

Page 22: ...s an identifier In the field Source Address the address of the device that sends the frame is defined If the field Transport Protocol is checked the frame use transport protocol functions used to send...

Page 23: ...The number 0 is the highest priority and 7 is the lowest In the field Data Page the Data Page is defined the value can be 0 or 1 usually it is 0 In the field PGN the PGN of J1939 message is defined i...

Page 24: ...cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 of Dip...

Page 25: ...am inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program more t...

Page 26: ...ccess section of SW67D26 Example 1 the converter is sending a LoRaWAN message related to row 4 of LoRaWAN Access LoRaWAN Uplink table of LoRaWAN Access section of SW67D26with a Num Byte set of 4 The d...

Page 27: ...ndustrial Electronic Devices ADFweb com S r l User Manual LoRaWAN J1939 Document code MN67D26_ENG Revision 1 000 Page 27 of 30 Figure 9 Mechanical dimensions scheme for SW67D26 B2 MECHANICAL DIMENSION...

Page 28: ...ing HD67D26 B 2 xxxMHz Frequency for LoRaWAN communication 868 868 MHz Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 4M 35mm DIN Rail mounting Device Family SW67D26 LoRaWAN J1939 Co...

Page 29: ...ystems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling...

Page 30: ...e following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the...

Reviews: