CHARACTERISTICS:

 

 

The HD67C54-B2 is a EnOcean / Modbus TCP Slave Converter. 

 

It allows the following characteristics: 

 

Electrical isolation between Ethernet and Power Supply; 

 

Mountable on 35mm Rail DIN; 

 

Wide power supply input range: 18…35V DC and 8…24V AC; 

 

Wide temperature range:  -40°C / 85°C [-40°F / +185°F]. 

 
 
CONFIGURATION: 
 

You need Compositor SW67C54 software on your PC in order to perform the following: 

 

Define the parameter of Modbus TCP line; 

 

Define the parameter of EnOcean line; 

 

Update the device. 

Summary of Contents for HD67C52-2-B2

Page 1: ...C50 Serial www adfweb com Product HD67C52 Modbus Slave www adfweb com Product HD67C54 Modbus TCP Slave www adfweb com Product HD67C56 BACnet Slave www adfweb com Product HD67C57 CAN www adfweb com Pro...

Page 2: ...ORT 27 RETURN POLICY 27 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you o...

Page 3: ...device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operatio...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual EnOcean Modbus TCP Slave Document code MN67C54_ENG Revision 1 000 Page 4 of 27 EXAMPLE OF CONNECTION...

Page 5: ...Industrial Electronic Devices ADFweb com S r l User Manual EnOcean Modbus TCP Slave Document code MN67C54_ENG Revision 1 000 Page 5 of 27 CONNECTION SCHEME Figure 1 Connection scheme for HD67C54 B2...

Page 6: ...It allows the following characteristics Electrical isolation between Ethernet and Power Supply Mountable on 35mm Rail DIN Wide power supply input range 18 35V DC and 8 24V AC Wide temperature range 40...

Page 7: ...67C54_ENG Revision 1 000 Page 7 of 27 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption...

Page 8: ...of the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used...

Page 9: ...n Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 EnOcean communication yellow Blinks when EnOcean data is received Blinks quickly Boot state Blinks very slow...

Page 10: ...CP communication The Ethernet connection must be made using Connector2 of HD67C54 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform t...

Page 11: ...t metering and lighting Each device uses a unique ID for identification and one of the standardized profiles EEPs for data transmission Communication process may be secure or unsecure and may be unidi...

Page 12: ...e Converter use the available software that runs with Windows called SW67C54 It is downloadable on the site www adfweb com and its operation is described in this document The software works with MS Wi...

Page 13: ...iguration A device s configuration can also be imported or exported To clone the configurations of a Programmable EnOcean Modbus TCP Slave Converter in order to configure another device in the same ma...

Page 14: ...the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible...

Page 15: ...cean Modbus TCP Slave Document code MN67C54_ENG Revision 1 000 Page 15 of 27 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside...

Page 16: ...for the Modbus TCP Slave section are In the fields IP ADDRESS the IP address of Modbus TCP side of the converter is defined In the fields SUBNET Mask the SubNet Mask of Modbus TCP side of the convert...

Page 17: ...code MN67C54_ENG Revision 1 000 Page 17 of 27 Figure 4 EnOcean Access window ENOCEAN ACCESS By Pressing the EnOcean Set Access button from the main window for SW67C54 Fig 2 the window EnOcean Set Acce...

Page 18: ...an device is defined In the field Secure Type the type of EnOcean communication is defined In the field Key the key used for encryption of frames in Secure Mode is defined In the field Rolling Code th...

Page 19: ...elds are In the field Rorg the type of EnOcean telegram is defined In the field Func the type of EnOcean instance is defined In the field Type the type of event is defined The means of the Variable fi...

Page 20: ...rnet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 o...

Page 21: ...program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program...

Page 22: ...reading Type Address Function Description Holding Register 0 03 Input Bytes 0 1 of internal array Holding Register 1 03 Input Bytes 2 3 of internal array Holding Register 2 03 Input Bytes 4 5 of inter...

Page 23: ...rnal array Input Register 1 04 Input Bytes 2 3 of internal array Input Register 2 04 Input Bytes 4 5 of internal array Data in writing Type Address Function Description Holding Register 0 R 03 W 06 16...

Page 24: ...ial Electronic Devices ADFweb com S r l User Manual EnOcean Modbus TCP Slave Document code MN67C54_ENG Revision 1 000 Page 24 of 27 Figure 9 Mechanical dimensions scheme for HD67C54 B2 MECHANICAL DIME...

Page 25: ...combination of the following HD67C54 B 2 Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 4M 35mm DIN Rail mounting Device Family HD67C54 EnOcean Modbus TCP Slave Converter Order Code...

Page 26: ...tion systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the rec...

Page 27: ...do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to...

Reviews: