ADF Web HD67B39-B2 User Manual Download Page 2

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

OPC UA Server / EtherNet/IP Slave 

 

Document code: MN67B39_ENG     Revision 1.000    Page 2 of 27

 

 

INDEX: 

 

 

Page 

INDEX 

UPDATED DOCUMENTATION  

REVISION LIST 

WARNING 

TRADEMARKS 

SECURITY ALERT 

EXAMPLE OF CONNECTION 

CONNECTION SCHEME 

CHARACTERISTICS 

CONFIGURATION 

POWER SUPPLY 

FUNCTION MODES 

LEDS 

ETHERNET 

10 

USE OF COMPOSITOR SW67B39 

11 

NEW PROJECT / OPEN PROJECT 

12 

SOFTWARE OPTIONS 

13 

SET COMMUNICATION  

15 

OPC UA ACCESS 

17 

UPDATE DEVICE 

18 

PLC CONFIGURATION 

20 

MECHANICAL DIMENSIONS 

24 

ORDERING INFORMATIONS 

25 

ACCESSORIES 

25 

DISCLAIMER 

26 

OTHER REGULATIONS AND STANDARDS 

 

26 

WARRANTIES AND TECHNICAL SUPPORT 

27 

RETURN POLICY 

27 

Pagina 2 di 27

 

UPDATED DOCUMENTATION: 
 

Dear  customer,  we  thank  you  for  your  attention  and  we  remind  you  that 
you need to check that the following document is: 

 

Updated 

 

Related to the product you own

 

 
To  obtain  the  most  recently  updated document,  note  the  “document  code” 
that appears at the top right-hand corner of each page of this document. 
 
With  this  “Document  Code”  go  to  web  page  www.adfweb.com/download/ 
and  search  for  the  corresponding  code  on  the  page.  Click  on  the  proper 
“Document Code” and download the updates. 

 

 

REVISION LIST: 

 

Revision 

Date 

Author  Chapter 

Description 

1.000 

13/03/2019 

Ff 

All 

First release version 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING: 
 

ADFweb.com reserves the right to change information in this manual about 
our product without warning. 
ADFweb.com is not responsible for any error this manual may contain.

 

 

 

TRADEMARKS: 
 

All  trademarks  mentioned  in  this  document  belong  to  their  respective 
owners. 

Summary of Contents for HD67B39-B2

Page 1: ...HD67B29 Modbus TCP Master www adfweb com Product HD67B30 Modbus TCP Slave www adfweb com Product HD67B31 Bacnet Master www adfweb com Product HD67B32 Bacnet Slave www adfweb com Product HD67B33 CAN ww...

Page 2: ...AND TECHNICAL SUPPORT 27 RETURN POLICY 27 Pagina 2 di 27 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Up...

Page 3: ...rlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation...

Page 4: ...tronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server EtherNet IP Slave Document code MN67B39_ENG Revision 1 000 Page 4 of 27 EXAMPL...

Page 5: ...eb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server EtherNet IP Slave Document code MN67B39_ENG Revision 1 000 Page 5 of 27 CONNECTION SCHEME Figure...

Page 6: ...ows the following characteristics Up to 496 bytes in reading and 496 bytes in writing Two directional information between EtherNet IP and OPC UA Mountable on 35mm Rail DIN Wide power supply input rang...

Page 7: ...EtherNet IP Slave Document code MN67B39_ENG Revision 1 000 Page 7 of 27 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin...

Page 8: ...he device has got two functions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 in Off position factory setting is used for the normal working of the device The second w...

Page 9: ...ot state Blinks very slowly 0 5Hz update in progress 2 OPC UA comm yellow Flashing OPC UA response OFF No OPC UA response Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 EtherN...

Page 10: ...RNET The Ethernet connection must be made using Connector3 of HD67B39 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 n...

Page 11: ...rter use the available software that runs with Windows called SW67B39 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the las...

Page 12: ...ontains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable OPC UA Server EtherNet IP Slave Converter in order to...

Page 13: ...there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section...

Page 14: ...438 30 91 31 User Manual OPC UA Server EtherNet IP Slave Document code MN67B39_ENG Revision 1 000 Page 14 of 27 In the section Software Settings it is possible to enable disable some keyboard s comman...

Page 15: ...or disabled pressing the Check Box field This feature is used for going out of the net In the field DNS the IP Address of the DNS server is defined This feature can be enabled or disabled pressing the...

Page 16: ...anual OPC UA Server EtherNet IP Slave Document code MN67B39_ENG Revision 1 000 Page 16 of 27 The means of the fields for NTP Network Time Protocol are In the field Server URL the URL or the IP Address...

Page 17: ...to define the list of OPC UA variables to read write The means of the checkboxes inside the table are If the field Enable is checked the OPC UA variable is enabled In the field Type the data format of...

Page 18: ...Turn ON the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations a...

Page 19: ...e LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator priv...

Page 20: ...IGURATION The configuration and commissioning of the EtherNet IP Converter as described on the following pages was accomplished with the help of the RSLogix 5000 software of Rockwell Automation In cas...

Page 21: ...address assigned is 192 168 0 5 For the Comm Format Data SINT shall be selected as the data type RSLogix 5000 requires a configuration assembly instance Both modules do not provide a configuration as...

Page 22: ...Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server EtherNet IP Slave Document code MN67B39_ENG Revision 1 000 Page 22 of 27 4 After the configuration is c...

Page 23: ...31 User Manual OPC UA Server EtherNet IP Slave Document code MN67B39_ENG Revision 1 000 Page 23 of 27 5 With RSLinks Classic Lite after have done a network scan RSWho and finding the EtherNet IP devic...

Page 24: ...rl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server EtherNet IP Slave Document code MN67B39_ENG Revision 1 000 Page 24 of 27 MECHANICAL DIMENSIONS Figure 7 M...

Page 25: ...number is formed by a valid combination of the following HD67B39 B 2 Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 2M 35mm DIN Rail mounting Device Family HD67B39 OPC UA Server Eth...

Page 26: ...pean countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an appl...

Page 27: ...ish to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information a...

Reviews: