ADF Web HD67B27-B2 User Manual Download Page 2

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

OPC UA Server / Modbus Master 

 

Document code: MN67B27_ENG     Revision 1.000    Page 2 of 27

 

INDEX: 

 

 

Page 

INDEX 

UPDATED DOCUMENTATION  

REVISION LIST 

WARNING 

TRADEMARKS 

SECURITY ALERT 

EXAMPLE OF CONNECTION 

CONNECTION SCHEME 

CHARACTERISTICS 

CONFIGURATION 

POWER SUPPLY 

FUNCTION MODES 

LEDS 

10 

RS232 

11 

RS485 

12 

ETHERNET 

13 

USE OF COMPOSITOR SW67B27 

14 

NEW CONFIGURATION / OPEN CONFIGURATION 

15 

SOFTWARE OPTIONS 

16 

SET COMMUNICATION  

18 

OPC UA ACCESS 

19 

MODBUS SET ACCESS 

20 

UPDATE DEVICE 

22 

MECHANICAL DIMENSIONS 

24 

ORDERING INFORMATIONS 

25 

ACCESSORIES 

25 

DISCLAIMER 

26 

OTHER REGULATIONS AND STANDARDS 

 

26 

WARRANTIES AND TECHNICAL SUPPORT 

27 

RETURN POLICY 

27 

Pagina 2 di 27

 

UPDATED DOCUMENTATION: 
 

Dear  customer,  we  thank  you  for  your  attention  and  we  remind  you  that 
you need to check that the following document is: 

 

Updated 

 

Related to the product you own

 

 
To  obtain  the  most  recently  updated document,  note  the  “document  code” 
that appears at the top right-hand corner of each page of this document. 
 
With  this  “Document  Code”  go  to  web  page  www.adfweb.com/download/ 
and  search  for  the  corresponding  code  on  the  page.  Click  on  the  proper 
“Document Code” and download the updates. 

 

 

REVISION LIST: 

 

Revision 

Date 

Author  Chapter 

Description 

1.000 

13/03/2019 

Nv 

All 

First release version 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING: 
 

ADFweb.com reserves the right to change information in this manual about 
our product without warning. 
ADFweb.com is not responsible for any error this manual may contain.

 

 

 

TRADEMARKS: 
 

All  trademarks  mentioned  in  this  document  belong  to  their  respective 
owners. 

Summary of Contents for HD67B27-B2

Page 1: ...67B30 Modbus TCP Slave www adfweb com Product HD67B31 Bacnet Master www adfweb com Product HD67B32 Bacnet Slave www adfweb com Product HD67B33 CAN www adfweb com Product HD67B34 CANopen www adfweb com...

Page 2: ...26 WARRANTIES AND TECHNICAL SUPPORT 27 RETURN POLICY 27 Pagina 2 di 27 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following...

Page 3: ...ocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation as...

Page 4: ...ectronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server Modbus Master Document code MN67B27_ENG Revision 1 000 Page 4 of 27 EXAMPLE...

Page 5: ...eb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server Modbus Master Document code MN67B27_ENG Revision 1 000 Page 5 of 27 CONNECTION SCHEME Figure 1a C...

Page 6: ...ices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server Modbus Master Document code MN67B27_ENG Revision 1 000 Page 6 of 27 Figure 1b Connection...

Page 7: ...verter It allows the following characteristics Up to 1500 bytes in reading and 1500 bytes in writing Two directional information between Modbus bus and OPC UA bus Mountable on 35mm Rail DIN Wide power...

Page 8: ...r Modbus Master Document code MN67B27_ENG Revision 1 000 Page 8 of 27 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin Vm...

Page 9: ...device has got two functions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 in Off position factory setting is used for the normal working of the device The second wit...

Page 10: ...s quickly Boot state Blinks very slowly 0 5Hz update in progress 2 Modbus comm yellow Flashing Modbus response OFF No Modbus response Blinks quickly Boot state Blinks very slowly 0 5Hz update in progr...

Page 11: ...OPC UA Server Modbus Master Document code MN67B27_ENG Revision 1 000 Page 11 of 27 RS232 The connection from RS232 socket to a serial port example one from a personal computer must be made with a Null...

Page 12: ...esistor it is necessary to put ON dip 1 like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foi...

Page 13: ...T The Ethernet connection must be made using Connector3 of HD67B27 x B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 no...

Page 14: ...er use the available software that runs with Windows called SW67B27 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last...

Page 15: ...ontains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable OPC UA Server Modbus Master Converter in order to conf...

Page 16: ...here is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section C...

Page 17: ...0438 30 91 31 User Manual OPC UA Server Modbus Master Document code MN67B27_ENG Revision 1 000 Page 17 of 27 In the section Software Settings it is possible to enable disable some keyboard s commands...

Page 18: ...is used for going out of the net In the field DNS the IP Address of the DNS server is defined This feature can be enabled or disabled pressing the Check Box field In the field Port the port of OPC UA...

Page 19: ...s Fig 4 This section is used to define the list of OPC UA variables to read write The means of the checkboxes inside the table are In the field Type the data format of the OPC UA variable is defined I...

Page 20: ...eld Type the data type of the register to read is defined It is possible to choose between the following o Coil Status o Input Status o Holding Register o Input Register In the field Address the start...

Page 21: ...eld Poll Time the delay time to make the request is defined If the field On Change is checked the converter sends the writing request when the data from OPC UA side change value If the field On CMD is...

Page 22: ...urn ON the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are...

Page 23: ...PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure tha...

Page 24: ...Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server Modbus Master Document code MN67B27_ENG Revision 1 000 Page 24 of 27 Figure 8 Mechanical dimensions sche...

Page 25: ...following HD67B27 B 2 Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 4M 35mm DIN Rail mounting Device Family HD67B27 OPC UA Server Modbus Master Converter Order Code HD67B27 2 A1 OPC...

Page 26: ...an countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applic...

Page 27: ...h to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information abo...

Reviews: