background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

OPC UA Client / EtherNet/IP Slave 

 

Document code: MN67B16_ENG     Revision 1.001    Page 3 of 32

 

 

SECURITY ALERT: 

 
G

ENERAL 

I

NFORMATION

 

To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and 
safety regulation are required for each individual application. The same applies also when using accessories. 

 

 

I

NTENDED 

U

SE

 

Machines  and  systems  must  be  designed  so  the  faulty  conditions  do  not  lead  to  a  dangerous  situation  for  the  operator  (i.e. 
independent limit switches, mechanical interlocks, etc.). 

 

Q

UALIFIED 

P

ERSONNEL

 

The device can be used only by qualified personnel, strictly in accordance with the specifications. 
Qualified personnel are persons who are familiar with the installation, assembly, commissioning and operation of this equipment and 
who have appropriate qualifications for their job. 

 

R

ESIDUAL 

R

ISKS

 

The device is state-of-the-art and is safe. The instruments can represent a potential hazard if they are inappropriately installed and 
operated by untrained personnel. These instructions refer to residual risks with the following symbol: 

 

This symbol indicates that non-observance of the safety instructions is a danger for people that could lead to serious injury or 
death and / or the possibility of damage. 

 

CE

 CONFORMITY

 

The declaration is made by our company. You can send an email to 

[email protected]

  or give us a call if you need it. 

 

 

Summary of Contents for HD67B16-B2

Page 1: ...lient from to www adfweb com Product HD67B08 Serial www adfweb com Product HD67B09 Modbus Slave www adfweb com Product HD67B10 Modbus TCP Slave www adfweb com Product HD67B11 Bacnet Slave www adfweb c...

Page 2: ...PORT 32 RETURN POLICY 32 Pagina 2 di 32 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to t...

Page 3: ...rlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation...

Page 4: ...tronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Client EtherNet IP Slave Document code MN67B16_ENG Revision 1 001 Page 4 of 32 EXAMPL...

Page 5: ...eb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Client EtherNet IP Slave Document code MN67B16_ENG Revision 1 001 Page 5 of 32 CONNECTION SCHEME Figure...

Page 6: ...wing characteristics Up to 1500 bytes in reading and 1500 bytes in writing Two directional information between EtherNet IP and OPC UA Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC...

Page 7: ...EtherNet IP Slave Document code MN67B16_ENG Revision 1 001 Page 7 of 32 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin...

Page 8: ...he device has got two functions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 in Off position factory setting is used for the normal working of the device The second w...

Page 9: ...inks very slowly 0 5Hz update in progress 2 OPC UA comm yellow Flashing OPC UA response OFF No OPC UA response Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 EtherNet IP comm...

Page 10: ...RNET The Ethernet connection must be made using Connector3 of HD67B16 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 n...

Page 11: ...rter use the available software that runs with Windows called SW67B16 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the las...

Page 12: ...ontains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable OPC UA Client EtherNet IP Slave Converter in order to...

Page 13: ...there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section...

Page 14: ...438 30 91 31 User Manual OPC UA Client EtherNet IP Slave Document code MN67B16_ENG Revision 1 001 Page 14 of 32 In the section Software Settings it is possible to enable disable some keyboard s comman...

Page 15: ...This feature can be enabled or disabled pressing the Check Box field This feature is used for going out of the net In the field DNS the IP Address of the DNS server is defined This feature can be ena...

Page 16: ...anual OPC UA Client EtherNet IP Slave Document code MN67B16_ENG Revision 1 001 Page 16 of 32 The means of the fields for NTP Network Time Protocol are In the field Server URL the URL or the IP Address...

Page 17: ...t IP Slave Document code MN67B16_ENG Revision 1 001 Page 17 of 32 Figure 4 OPC UA Client Access window OPC UA ACCESS By Pressing the OPC UA Client Access button from the main window for SW67B16 Fig 2...

Page 18: ...001 Page 18 of 32 Figure 5 Add OPC UA Server Figure 6 Modify OPC UA Server By clicking on Add it is possible to add a new OPC UA Server inserting its characteristics Server Address Authorization Secu...

Page 19: ...r OPC UA window By clicking on Scan it is possible to get the list of available variables from the selected Server The window Scan Server OPC UA appears Fig 7 The means of the checkboxes inside the ta...

Page 20: ...fields are If the field Enable is checked the OPC UA variable is enabled In the field Display name the name of the OPC UA variable is defined In the field Node Type the type of the OPC UA node which i...

Page 21: ...In the field Node Type the type of the OPC UA node which includes the variable is defined In the field Node ID the name of the OPC UA node which includes the variable is defined In the field Var Type...

Page 22: ...Position the starting byte of the EtherNet IP array where getting the value is defined In the field Mnemonic a description of the variable is defined Note By clicking on Auto Pos the position of the...

Page 23: ...Turn ON the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations ar...

Page 24: ...r PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure t...

Page 25: ...N for EtherNet IP The configuration and commissioning of the EtherNet IP Converter as described on the following pages was accomplished with the help of the RSLogix 5000 software of Rockwell Automatio...

Page 26: ...address assigned is 192 168 0 5 For the Comm Format Data SINT shall be selected as the data type RSLogix 5000 requires a configuration assembly instance Both modules do not provide a configuration as...

Page 27: ...Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Client EtherNet IP Slave Document code MN67B16_ENG Revision 1 001 Page 27 of 32 4 After the configuration is c...

Page 28: ...31 User Manual OPC UA Client EtherNet IP Slave Document code MN67B16_ENG Revision 1 001 Page 28 of 32 5 With RSLinks Classic Lite after have done a network scan RSWho and finding the EtherNet IP devic...

Page 29: ...l IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Client EtherNet IP Slave Document code MN67B16_ENG Revision 1 001 Page 29 of 32 MECHANICAL DIMENSIONS Figure 12 M...

Page 30: ...number is formed by a valid combination of the following HD67B16 B 2 Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 4M 35mm DIN Rail mounting Device Family HD67B16 OPC UA Client Eth...

Page 31: ...pean countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an appl...

Page 32: ...ish to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information a...

Reviews: