background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

PROFINET/ HART Master

 

 

Document code: MN67912_ENG     Revision 1.000   Page 1 of 30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

Revision 1.000 
English

 

 

PROFINET / HART Master - Converter

  

(Order Code:  HD67912-A1) 

 

For Website information:  

www.adfweb.com?Product=HD67912

   

 

For Price information: 

www.adfweb.com?Price=HD67912-A1

  

 

Benefits and Main Features: 

 

Very easy to configure 

 

Triple Electrical isolation 

 

Temperature range: -40°C/+85°C (-40°F/+185°F) 

For other HART products see also the following link: 

 

Converter HART Master to  

www.adfweb.com?Product=HD67900

      

(Serial) 

www.adfweb.com?Product=HD67901

       

(BACnet Slave) 

www.adfweb.com?Product=HD67902

      

(CAN) 

www.adfweb.com?Product=HD67903

       

(CANopen) 

www.adfweb.com?Product=HD67904

       

(DeviceNet Slave) 

www.adfweb.com?Product=HD67905

      

(Ethernet) 

www.adfweb.com?Product=HD67906

      

(EtherNet/IP Slave) 

www.adfweb.com?Product=HD67907

      

(J1939) 

www.adfweb.com?Product=HD67908

       

(Modbus Slave) 

www.adfweb.com?Product=HD67909

       

(Modbus TCP Slave) 

www.adfweb.com?Product=HD67910

      

(MQTT) 

www.adfweb.com?Product=HD67911

      

(PROFIBUS Slave) 

www.adfweb.com?Product=HD67913

      

(SNMP Agent) 

 
Do you have your customer protocol? Then go to: 

www.adfweb.com?Product=HD67003

 

 

Do you need to choose a device? Do you want help? 

www.adfweb.com?Cmd=helpme

 

 

User Manual   

 

Summary of Contents for HD67912-A1

Page 1: ...aster to www adfweb com Product HD67900 Serial www adfweb com Product HD67901 BACnet Slave www adfweb com Product HD67902 CAN www adfweb com Product HD67903 CANopen www adfweb com Product HD67904 Devi...

Page 2: ...ICAL SUPPORT 29 RETURN POLICY 30 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the prod...

Page 3: ...vice can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual PROFINET HART Master Document code MN67912_ENG Revision 1 000 Page 4 of 30 EXAMPLES OF CONNECTION...

Page 5: ...Industrial Electronic Devices ADFweb com S r l User Manual PROFINET HART Master Document code MN67912_ENG Revision 1 000 Page 5 of 30 CONNECTION SCHEME Figure 1 Connection scheme for HD67912 A1...

Page 6: ...upply Ethernet HART HART Power Supply Two directional information between Ethernet bus and HART bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature rang...

Page 7: ...12_ENG Revision 1 000 Page 7 of 30 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at...

Page 8: ...ith Dip2 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip2 of Dip Switch A at ON position is used for uploading the Project and or Firmware For the oper...

Page 9: ...munication green It blinks when HART communication is running Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 Ethernet link green ON Ethernet cable connected OFF Ethernet cable...

Page 10: ...als at a low level on top of the 4 20mA This enables two way field communication to take place and makes it possible for additional information beyond just the normal process variable to be communicat...

Page 11: ...ation must be made using Connector4 of the HD67912 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to co...

Page 12: ...uns with Windows called SW67912 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on o...

Page 13: ...configuration A device s configuration can also be imported or exported To clone the configurations of a programmable PROFINET HART Master in order to configure another device in the same manner it i...

Page 14: ...e language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to...

Page 15: ...ROFINET HART Master Document code MN67912_ENG Revision 1 000 Page 15 of 30 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside th...

Page 16: ...he SubNet Mask of the converter is defined In the field GATEWAY the default gateway of the network is defined This feature can be enabled or disabled pressing the Check Box field This feature is used...

Page 17: ...to read write with the PROFINET Master The means of the fields are If the field Enable is checked the HART variable is enabled In the field Device Address the address of HART device is defined In the...

Page 18: ...e HART data is defined In the field Swap the bytes order is reversed In the field Conv Int the data from HART device is converted in Integer format In the field Operations a post operation on the data...

Page 19: ...et cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip2 of...

Page 20: ...rogram inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program mo...

Page 21: ...trial Electronic Devices ADFweb com S r l User Manual PROFINET HART Master Document code MN67912_ENG Revision 1 000 Page 21 of 30 MECHANICAL DIMENSIONS Figure 7 Mechanical dimensions scheme for HD6791...

Page 22: ...ables section It has the following characteristics Possibility to scan HART network Automatic decode of HART messages Easy connection directly through the Ethernet port of the converter In order to st...

Page 23: ...configured in the converter Start the Scan by clicking on Start Scan button The window will appear like below When the Scan is complete the software will show the results You can import the data by cl...

Page 24: ...tion Each bit will represent the status of a HART request If for a request the converter receives a correct response the status bit is put to 0 If for a request the converter receives a wrong response...

Page 25: ...TION The configuration and commissioning of the PROFINET Converter as described on the following pages was accomplished with the help of the TIA Portal software of Siemens In case of using a control s...

Page 26: ...es ADFweb com S r l User Manual PROFINET HART Master Document code MN67912_ENG Revision 1 000 Page 26 of 30 2 Import the module in the network connect the device to the PLC network and edit the parame...

Page 27: ...Industrial Electronic Devices ADFweb com S r l User Manual PROFINET HART Master Document code MN67912_ENG Revision 1 000 Page 27 of 30 3 Load the configuration into the PLC...

Page 28: ...lid combination of the following HD67912 xx Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67912 PROFINET HART Master Converter Order Code HD...

Page 29: ...on systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recyc...

Page 30: ...the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to t...

Reviews: