Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

Modbus TCP Slave / HART Master

 

 

Document code: MN67909_ENG     Revision 1.001   Page 1 of 30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

Revision 1.001 
English

 

 

Modbus TCP Slave / HART Master - Converter

  

(Order Code:  HD67909-A1) 

 

For Website information:  

www.adfweb.com?Product=HD67909

   

 

For Price information: 

www.adfweb.com?Price=HD67909-A1

  

 

Benefits and Main Features: 

 

Very easy to configure 

 

Triple Electrical isolation 

 

Temperature range: -40°C/+85°C (-40°F/+185°F) 

For other HART products see also the following link: 

 

Converter HART Master to  

www.adfweb.com?Product=HD67900

      

(Serial) 

www.adfweb.com?Product=HD67901

       

(BACnet Slave) 

www.adfweb.com?Product=HD67902

      

(CAN) 

www.adfweb.com?Product=HD67903

       

(CANopen) 

www.adfweb.com?Product=HD67904

       

(DeviceNet Slave) 

www.adfweb.com?Product=HD67905

      

(Ethernet) 

www.adfweb.com?Product=HD67906

      

(EtherNet/IP Slave) 

www.adfweb.com?Product=HD67907

      

(J1939) 

www.adfweb.com?Product=HD67908

       

(Modbus Slave) 

www.adfweb.com?Product=HD67910

      

(MQTT) 

www.adfweb.com?Product=HD67911

      

(PROFIBUS Slave) 

www.adfweb.com?Product=HD67912

       

(PROFINET Slave) 

www.adfweb.com?Product=HD67913

      

(SNMP Agent) 

 
Do you have your customer protocol? Then go to: 

www.adfweb.com?Product=HD67003

 

 

Do you need to choose a device? Do you want help? 

www.adfweb.com?Cmd=helpme

 

 

User Manual   

 

Summary of Contents for HD67909-A1

Page 1: ...er HART Master to www adfweb com Product HD67900 Serial www adfweb com Product HD67901 BACnet Slave www adfweb com Product HD67902 CAN www adfweb com Product HD67903 CANopen www adfweb com Product HD6...

Page 2: ...URN POLICY 30 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obta...

Page 3: ...e device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operat...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual Modbus TCP Slave HART Master Document code MN67909_ENG Revision 1 001 Page 4 of 30 EXAMPLES OF CONNECTION...

Page 5: ...ndustrial Electronic Devices ADFweb com S r l User Manual Modbus TCP Slave HART Master Document code MN67909_ENG Revision 1 001 Page 5 of 30 CONNECTION SCHEME Figure 1a Connection scheme for HD67909 A...

Page 6: ...ART Power Supply Two directional information between Ethernet bus and HART bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185...

Page 7: ...N67909_ENG Revision 1 001 Page 7 of 30 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumptio...

Page 8: ...st with Dip2 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip2 of Dip Switch A at ON position is used for uploading the Project and or Firmware For the...

Page 9: ...communication green It blinks when HART communication is running Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 Ethernet link green ON Ethernet cable connected OFF Ethernet c...

Page 10: ...signals at a low level on top of the 4 20mA This enables two way field communication to take place and makes it possible for additional information beyond just the normal process variable to be commun...

Page 11: ...unication must be made using Connector4 of the HD67909 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative t...

Page 12: ...at runs with Windows called SW67909 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present...

Page 13: ...configuration A device s configuration can also be imported or exported To clone the configurations of a programmable Modbus TCP Slave HART Master in order to configure another device in the same man...

Page 14: ...e the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible...

Page 15: ...s TCP Slave HART Master Document code MN67909_ENG Revision 1 001 Page 15 of 30 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation insid...

Page 16: ...case of missing response from HART device is defined The means of the fields for the Modbus Slave section are In the field IP Address the IP address of the converter is defined In the field SubNet Mas...

Page 17: ...bles to read write with the Modbus Master The means of the fields are If the field Enable is checked the HART variable is enabled In the field Device Address the address of HART device is defined In t...

Page 18: ...g the HART data is defined In the field Swap the bytes order is reversed In the field Conv Int the data from HART device is converted in Integer format In the field Operations a post operation on the...

Page 19: ...hernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip2...

Page 20: ...he program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to progra...

Page 21: ...Variables section It has the following characteristics Possibility to scan HART network Automatic decode of HART messages Easy connection directly through the Ethernet port of the converter In order t...

Page 22: ...ess configured in the converter Start the Scan by clicking on Start Scan button The window will appear like below When the Scan is complete the software will show the results You can import the data b...

Page 23: ...like Internet Explorer Google Chrome Mozilla Firefox by editing the IP Address of the converter in the address bar of the browser WELCOME As soon as the connection to the Webserver interface of the D...

Page 24: ...Slave HART Master Document code MN67909_ENG Revision 1 001 Page 24 of 30 When one of the buttons of the Welcome page are pressed it is necessary to do the login using the Admin and Password defined in...

Page 25: ...Scan button is pressed the HART Scan window appears Fig 10 It has the following fields NUMBER OF DEVICES TO SEARCH FOR Maximum 16 field number of Hart devices connected Scan Start button it is possibl...

Page 26: ...a discovered HART node from HART Scan section is selected the HART Control window appears Fig 11 It has the following fields UNIQUE ID button it is possible to insert the unique ID of the HART device...

Page 27: ...l Electronic Devices ADFweb com S r l User Manual Modbus TCP Slave HART Master Document code MN67909_ENG Revision 1 001 Page 27 of 30 MECHANICAL DIMENSIONS Figure 12 Mechanical dimensions scheme for H...

Page 28: ...on of the following HD67909 xx Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67909 Modbus TCP Slave HART Master Converter Order Code HD67909...

Page 29: ...ection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the r...

Page 30: ...e do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product...

Reviews: