background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

J1939 / KNX

 

 

Document code: MN67810_ENG     Revision 1.001   Pagina 1 di 26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

Revision 1.001 
English 

 

J1939 / KNX - Converter 

 (Order Code:  HD67810-KNX-B2) 

 
for Website information:  

www.adfweb.com?Product=HD67810

 

 

for Price information: 

www.adfweb.com?Price=HD67810-KNX-B2

  

 
 

Benefits and Main Features: 

 

Very easy to configure 

 

Electrical isolation 

 

Temperature range: -40°C/85°C (-40°F/185°F) 

 

For others KNX products, see also the following links: 

 

Converter KNX to  

www.adfweb.com?Product=HD67801

      

(BACnet Master)

 

www.adfweb.com?Product=HD67802

      

(BACnet Slave) 

www.adfweb.com?Product=HD67803

       

(CAN) 

www.adfweb.com?Product=HD67804

      

(CANopen) 

www.adfweb.com?Product=HD67807

      

(EtherNet/IP) 

www.adfweb.com?Product=HD67808

      

(DeviceNet Master) 

www.adfweb.com?Product=HD67809

      

(DeviceNet Slave) 

www.adfweb.com?Product=HD67811

       

(M-Bus Master/wM-Bus) 

www.adfweb.com?Product=HD67812

        

(Modbus Master) 

www.adfweb.com?Product=HD67813

      

(Modbus Slave)

 

www.adfweb.com?Product=HD67814

       

(Modbus TCP Master)

 

www.adfweb.com?Product=HD67815

       

(Modbus TCP Slave) 

www.adfweb.com?Product=HD67818

       

(PROFINET) 

www.adfweb.com?Product=HD67820

       

(SNMP) 

www.adfweb.com?Product=HD67821

       

(DMX) 

www.adfweb.com?Product=HD67822

       

(DALI) 

www.adfweb.com?Product=HD67825

       

(Ethernet) 

 

 

Do you have an your customer protocol? 

www.adfweb.com?Product=HD67003

 

 

Do you need to choose a device? do you want help? 

www.adfweb.com?Cmd=helpme

 

 

User Manual   

 

Summary of Contents for HD67810-KNX-B2

Page 1: ...m Product HD67802 BACnet Slave www adfweb com Product HD67803 CAN www adfweb com Product HD67804 CANopen www adfweb com Product HD67807 EtherNet IP www adfweb com Product HD67808 DeviceNet Master www...

Page 2: ...D TECHNICAL SUPPORT 26 RETURN POLICY 26 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to t...

Page 3: ...QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly c...

Page 4: ...trial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 KNX Document code MN67810_ENG Revision 1 001 Pagina 4 di 26 EXAMPLE OF CONNE...

Page 5: ...ces ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 KNX Document code MN67810_ENG Revision 1 001 Pagina 5 di 26 CONNECTION SCHEME Figure 1 Connection...

Page 6: ...ctional information between KNX bus and J1939 bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Comp...

Page 7: ...KNX Document code MN67810_ENG Revision 1 001 Pagina 7 di 26 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 2...

Page 8: ...functions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch...

Page 9: ...Blinks very slowly 0 5Hz update in progress 2 J1939 communication yellow Blinks when J1939 frame is received Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 KNX communication y...

Page 10: ...n 1 001 Pagina 10 di 26 J1939 For terminate the J1939 line with a 120 resistor it is necessary that the Dip1 of Dip Switch C is at ON position Cable characteristics DC parameter Impedance 70 Ohm m AC...

Page 11: ...ing to control dampers to the security to the heating monitoring to the conditioning to the hydric control and alarms to energy management and so on Characteristics Description TP1 256 Medium Shielded...

Page 12: ...e used for programming the device The Ethernet connection must be made using Connector2 of HD67810 KNX B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The c...

Page 13: ...he available software that runs with Windows called SW67810 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version...

Page 14: ...contains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a Programmable J1939 KNX Converter in order to configure another dev...

Page 15: ...the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connectio...

Page 16: ...side of the converter is defined The means of the fields for the J1939 section are In the field Baudrate the baudrate for the J1939 line is defined In the field TimeOut Data s a time is defined When t...

Page 17: ...ted by In the field APCI the APCI of the KNX message is defined You can choose between the following o Read it is used to send a reading request to a KNX device o Write it is used to send a writing re...

Page 18: ...he information In the field Bit Mode insert the start bit of the first byte of the field Position where start to insert the data read In the field Length the dimension of the KNX message is defined In...

Page 19: ...d in the J1939 protocol the PGN is an identifier In the field Source Address the source address of the device that send the frame is defined If the field Transport Protocol is checked the frame uses T...

Page 20: ...the field Data Page the data page of the J1939 message is defined The value can be 0 or 1 usually it is 0 In the field PGN the PGN of the J1939 message to be written from KNX is defined in J1939 prot...

Page 21: ...n Device Found must appear Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device...

Page 22: ...g Try with another PC Try to restart the PC Check the LAN settings Check the Wi Fi settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are usi...

Page 23: ...eb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 KNX Document code MN67810_ENG Revision 1 001 Pagina 23 di 26 MECHANICAL DIMENSIONS Figure 9 Mechanical di...

Page 24: ...D67810 KNX B 2 Connectors Type 2 Fixed 5mm Screw Terminal Enclosure Type B 4M 35mm DIN Rail mounting Device Family HD67810 KNX J1939 KNX Converter Order Code HD67810 KNX B2 J1939 KNX Converter ACCESSO...

Page 25: ...ries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable col...

Page 26: ...hange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the p...

Reviews: