background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

BACnet Master / PROFIBUS Slave

 

 

Document code: MN67716_ENG     Revision 1.001   Page 1 of 28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

Revision 1.001 
English

 

 

BACnet Master / PROFIBUS Slave - Converter

  

(Order Code:  HD67716-IP-A1, HD67716-MSTP-A1) 

 

For Website information:  

www.adfweb.com?Product=HD67716

  

 

For Price information: 

www.adfweb.com?Price=HD67716-IP-A1

 

www.adfweb.com?Price=HD67716-MSTP-A1

  

 

 

Benefits and Main Features: 

 

Very easy to configure 

 

Triple Electrical isolation 

 

Temperature range: -40°C/+85°C (-40°F/+185°F) 

For other BACnet Master products see also the following link: 

 

Converter BACnet Master to 

www.adfweb.com?Product=HD67704

      

(DMX) 

 

www.adfweb.com?Product=HD67712

      

(Modbus Slave) 

www.adfweb.com?Product=HD67714

      

(Modbus TCP Slave) 

www.adfweb.com?Product=HD67717

      

(CAN)

 

www.adfweb.com?Product=HD67718

      

(CANopen)

 

www.adfweb.com?Product=HD67719

      

(PROFINET)

 

www.adfweb.com?Product=HD67721

      

(DeviceNet Slave) 

www.adfweb.com?Product=HD67722

      

(EtherNet/IP)

 

www.adfweb.com?Product=HD67723

      

(NMEA 2000)

 

www.adfweb.com?Product=HD67725

      

(J1939) 

www.adfweb.com?Product=HD67726

      

(SNMP Agent)

 

www.adfweb.com?Product=HD67801

      

(KNX)

 

www.adfweb.com?Product=HD67832

      

(DALI)

 

 
Do you have your customer protocol? Then go to: 

www.adfweb.com?Product=HD67003

 

 

Do you need to choose a device? Do you want help? 

www.adfweb.com?Cmd=helpme

 

 

User Manual   

 

Summary of Contents for HD67716-IP-A1

Page 1: ...roducts see also the following link Converter BACnet Master to www adfweb com Product HD67704 DMX www adfweb com Product HD67712 Modbus Slave www adfweb com Product HD67714 Modbus TCP Slave www adfweb...

Page 2: ...URN POLICY 28 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obta...

Page 3: ...e device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operat...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual BACnet Master PROFIBUS Slave Document code MN67716_ENG Revision 1 001 Page 4 of 28 EXAMPLES OF CONNECTION...

Page 5: ...ustrial Electronic Devices ADFweb com S r l User Manual BACnet Master PROFIBUS Slave Document code MN67716_ENG Revision 1 001 Page 5 of 28 CONNECTION SCHEME Figure 1a Connection scheme for HD67716 IP...

Page 6: ...Industrial Electronic Devices ADFweb com S r l User Manual BACnet Master PROFIBUS Slave Document code MN67716_ENG Revision 1 001 Page 6 of 28 Figure 1b Connection scheme for HD67716 MSTP A1...

Page 7: ...tween PROFIBUS Power Supply PROFIBUS BACnet BACnet Power Supply Two directional information between PROFIBUS bus and BACnet bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12...

Page 8: ...001 Page 8 of 28 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at 24V DC Device Co...

Page 9: ...st with Dip2 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip2 of Dip Switch A at ON position is used for uploading the Project and or Firmware For the...

Page 10: ...BUS comm green Blinks quickly when PROFIBUS communication is working Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 Device state green Blinks slowly 1Hz Blinks quickly Boot st...

Page 11: ...use of a straight cable to connect the device to a PC PLC other is recommended the use of a cross cable RS485 The BACnet MS TP connection must be made using Connector5 of HD67716 MSTP A1 To terminate...

Page 12: ...PROFIBUS Slave Document code MN67716_ENG Revision 1 001 Page 12 of 28 PROFIBUS The PROFIBUS uses a 9 pin D SUB connector The pin assignment is defined like in the right figure Here some codes of cabl...

Page 13: ...at runs with Windows called SW67716 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present...

Page 14: ...iguration A device s configuration can also be imported or exported To clone the configurations of a programmable BACnet Master PROFIBUS Slave Converter in order to configure another device in the sam...

Page 15: ...ge the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possibl...

Page 16: ...t Master PROFIBUS Slave Document code MN67716_ENG Revision 1 001 Page 16 of 28 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation insid...

Page 17: ...S the IP address of BACnet IP side of the converter is defined In the field SUBNET Mask the SubNet Mask of the converter is defined In the field GATEWAY the default gateway of the net is defined This...

Page 18: ...owable address for master nodes The value shall be less than or equal to 127 The field Max Info Frames specifies the maximum number of information frames the node may send before it must pass the toke...

Page 19: ...e window Read are the follows In the field IP Address ID the IP address ID of the slave that contains the data to be read is defined In the field Object Type the BACnet object to read is defined In th...

Page 20: ...n the field Poll Time the frequency of the request is defined In the field Max Error the number of consecutive errors that the Master waits before discard the row from the cycle of requests is defined...

Page 21: ...Byte the number of bytes to take from PROFIBUS array is defined By checking the field En Dest it is possible to enable the Destination Network D Net Destination Length D Len and Destination Address D...

Page 22: ...d Start Bit is used for the Binary BACnet objects It is possible to select the bit in the byte from which taking the data By checking the field Swap it is possible to swap the order of data to write t...

Page 23: ...Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip2 of Dip Switch A in...

Page 24: ...s for the updating Try with another PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windo...

Page 25: ...S r l User Manual BACnet Master PROFIBUS Slave Document code MN67716_ENG Revision 1 001 Page 25 of 28 MECHANICAL DIMENSIONS Figure 7a Mechanical dimensions scheme for HD67716 IP A1 Figure 7b Mechanic...

Page 26: ...Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting BACnet type IP BACnet IP MSTP BACnet MS TP Device Family HD67716 BACnet Master PROFIBUS Slave Converter Order Code HD67716 IP A...

Page 27: ...ection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the r...

Page 28: ...e do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product...

Reviews: