background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

DMX / Modbus Slave

 

 

Document code: MN67517_ENG     Revision 1.000   Page 1 of 24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

Revision 1.000 
English 

 

DMX / Modbus Slave - Converter 

 (Order Code:  HD67517-B2) 

 

For Website information:  

www.adfweb.com?Product=HD67517

 

 

For Price information: 

www.adfweb.com?Price=HD67517-B2

 

 
 

Benefits and Main Features: 

 

Very easy to configure 

 

Triple electrical isolation 

 

Temperature range: -40°C/85°C (-40°F/185°F) 

 

For others DMX products see also the following link: 

 

Converter DMX to  

www.adfweb.com?Product=HD67039

      

(Ethernet)

 

www.adfweb.com?Product=HD67040

      

(SNMP Agent) 

www.adfweb.com?Product=HD67041

       

(SNMP Manager) 

www.adfweb.com?Product=HD67046

       

(Serial) 

www.adfweb.com?Product=HD67509

       

(Modbus TCP Slave) 

www.adfweb.com?Product=HD67518

       

(Modbus Master) 

www.adfweb.com?Product=HD67519

       

(Modbus TCP Master) 

www.adfweb.com?Product=HD67588

     

(EtherNet/IP Slave) 

www.adfweb.com?Product=HD67614

      

(PROFINET Slave)

 

www.adfweb.com?Product=HD67670

       

(BACnet Slave) 

www.adfweb.com?Product=HD67704

      

(BACnet Master) 

www.adfweb.com?Product=HD67821

       

(KNX) 

www.adfweb.com?Product=HD67838

       

(DALI) 

www.adfweb.com?Product=HD67944

       

(MQTT) 

www.adfweb.com?Product=HD67B15

       

(OPC UA Client) 

www.adfweb.com?Product=HD67B37

        

(OPC UA Server) 

www.adfweb.com?Product=HD67D23

       

(LoRaWAN) 

www.adfweb.com?Product=HD67E11

       

(EtherCAT Slave) 

 

 

Do you have an your customer protocol? 

www.adfweb.com?Product=HD67003

 

 

Do you need to choose a device? do you want help? 

www.adfweb.com?Cmd=helpme

 

 

User Manual   

 

Summary of Contents for HD67517-B2

Page 1: ...041 SNMP Manager www adfweb com Product HD67046 Serial www adfweb com Product HD67509 Modbus TCP Slave www adfweb com Product HD67518 Modbus Master www adfweb com Product HD67519 Modbus TCP Master www...

Page 2: ...UPPORT 24 RETURN POLICY 24 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product yo...

Page 3: ...ce can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual DMX Modbus Slave Document code MN67517_ENG Revision 1 000 Page 4 of 24 EXAMPLE OF CONNECTION...

Page 5: ...Industrial Electronic Devices ADFweb com S r l User Manual DMX Modbus Slave Document code MN67517_ENG Revision 1 000 Page 5 of 24 CONNECTION SCHEME Figure 1 Connection scheme for HD67517 B2...

Page 6: ...teristics Triple isolation between Modbus Power Supply Modbus DMX Power Supply DMX Two directional information between Modbus bus and DMX bus Mountable on 35mm Rail DIN Wide power supply input range 8...

Page 7: ...7_ENG Revision 1 000 Page 7 of 24 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at...

Page 8: ...he position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used for...

Page 9: ...Hz ON Device powered OFF Device not powered 2 Modbus communication yellow Blinks when a Modbus request is received Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 DMX communica...

Page 10: ...dip 1 like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil shield braid shield Belden p n 8...

Page 11: ...ble should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil shield braid shield Belden p n 82842 2x 24AWG stranded twisted pairs conductor fo...

Page 12: ...Ethernet connection must be made using Connector2 of HD67517 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms rel...

Page 13: ...with Windows called SW67517 It is downloadable from the site www adfweb com and its operation is described in this document this manual is referenced to the last version of the software present on ou...

Page 14: ...iguration A device s configuration can also be imported or exported To clone the configurations of a Programmable DMX Modbus slave Converter in order to configure another device in the same manner it...

Page 15: ...language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to c...

Page 16: ...DMX Modbus Slave Document code MN67517_ENG Revision 1 000 Page 16 of 24 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside the...

Page 17: ...he serial port to use is defined In the field Baudrate the baudrate for the serial line is defined In the field Parity the parity of the serial line is defined In the field Stop Bits the number of Sto...

Page 18: ...0 Page 18 of 24 DMX DEFAULT VALUE By pressing the DMX Default Value button from the main window for SW67517 Fig 2 the DMX Default Value window appears Fig 4 In this section it is possible to define th...

Page 19: ...cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 of Di...

Page 20: ...estart the PC Check the LAN settings Check the Wi Fi settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10...

Page 21: ...ustrial Electronic Devices ADFweb com S r l User Manual DMX Modbus Slave Document code MN67517_ENG Revision 1 000 Page 21 of 24 MECHANICAL DIMENSIONS Figure 7 Mechanical dimensions scheme for HD67517...

Page 22: ...by a valid combination of the following HD67517 B 2 Connectors Type 2 Fixed 5mm Screw Terminal Enclosure Type B 2M 35mm DIN Rail mounting Device Family HD67517 DMX Modbus slave Converter Order Code H...

Page 23: ...systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycli...

Page 24: ...he following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the...

Reviews: