CAN /Modbus Master - Converter 

 

Document code: MN67411_ENG     Revision 2.101    Page 1 of 32 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

 

User Manual 

Revision 2.101 
English 

 

CAN / Modbus Master – Converter 

(Order Code: HD67411) 

 

For Website information:  

www.adfweb.com?Product=HD67411

  

  

 

For Price information: 

www.adfweb.com?Price=HD67411

     

 

 

Benefits and Main Features: 

 

Very easy to configure 

 

Wide supply input range 

 

Electrical isolation 

 

Industrial temperature range: 

 

-40°C / 105°C  (-40°F / 221°F) 

 

For other Gateways / Bridges: 

CAN from/to Modbus 

See also the following links: 

www.adfweb.com?product=HD67012

 

(Modbus RTU Slave) 

www.adfweb.com?product=HD67514

 

(Modbus TCP Master) 

www.adfweb.com?product=HD67515

 

(Modbus TCP Slave) 

 

CANopen from/to Modbus 

See also the following links: 

www.adfweb.com?product=HD67001

 

(Modbus RTU Master) 

www.adfweb.com?product=HD67502

 

(Modbus RTU Slave) 

www.adfweb.com?product=HD67504

 

(Modbus TCP Master) 

www.adfweb.com?product=HD67505

 

(Modbus TCP Slave) 

 

Do you have an your customer protocol? 

See the following links: 

www.adfweb.com?Product=HD67003

 

 
Do you need to choose a device? do you want help? 

Ask it to the following link: 

www.adfweb.com?Cmd=helpme

 

 

User Manual   

 

Summary of Contents for HD67411

Page 1: ...ture range 40 C 105 C 40 F 221 F For other Gateways Bridges CAN from to Modbus See also the following links www adfweb com product HD67012 Modbus RTU Slave www adfweb com product HD67514 Modbus TCP Ma...

Page 2: ...ATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated d...

Page 3: ...ocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation as...

Page 4: ...ectronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN Modbus Master Converter Document code MN67411_ENG Revision 2 101 Page 4 of 32 EXAMPLE...

Page 5: ...b com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN Modbus Master Converter Document code MN67411_ENG Revision 2 101 Page 5 of 32 CONNECTION SCHEME Figure 1a Co...

Page 6: ...ces ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN Modbus Master Converter Document code MN67411_ENG Revision 2 101 Page 6 of 32 Figure 1b Connection...

Page 7: ...MP SuperSeal 1 5 connectors If is resined the enclosure like the AMP SuperSeal 1 5 connectors is waterproof All the four series have these characteristics Triple 4kV isolation between Power Supply RS4...

Page 8: ...8 of 32 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax HD67411 Exx xxx 8V 26V 10V 40V Consumption at 24V...

Page 9: ...The various meanings of the LEDs are described in the table below LED Normal Mode Boot Mode 1 Device state green Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress...

Page 10: ...ine with a 220 resistor in the HD67411 Exx xxx is made internally of the device when the order is performed If the device have the RS485 terminated the code is the follow HD67411 Exx xYx otherwise is...

Page 11: ...he HD67411 E7x xxx device must be made with a AMP SuperSeal 1 5 Male connector The pinout of Female connector of the board is at right side of the page The termination of CAN line with a 120 resistor...

Page 12: ...www adfweb com Phone 39 0438 30 91 31 User Manual CAN Modbus Master Converter Document code MN67411_ENG Revision 2 101 Page 12 of 32 USB The USB port is used to start the converter in Boot Mode and t...

Page 13: ...er use the available software that runs with Windows called SW67411 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last...

Page 14: ...ich contains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable CAN Modbus Master Converter in order to configure...

Page 15: ...here is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section C...

Page 16: ...0438 30 91 31 User Manual CAN Modbus Master Converter Document code MN67411_ENG Revision 2 101 Page 16 of 32 In the section Software Settings it is possible to enable disable some keyboard s commands...

Page 17: ...sed in milliseconds is defined In the field HB CobID the COB ID of the HeartBeat message is defined In the field HB CAN Type the type of CAN communication for HeartBeat message is defined In the field...

Page 18: ...e is defined In the field CAN Type the type of the CAN protocol used for each frame CAN 2 0A 11 bits or CAN 2 0B 29 bits is defined In the field Address Device the ID of the Modbus slave to read is de...

Page 19: ...23 and without data Fig 5 As an answer we would have a CAN bus frame with COB ID 291 0x123 and 8 bytes of data They are the value of the Modbus registers 2 In the second case of the table the item has...

Page 20: ...re the meanings of the various fields that composes the table In the field Cob ID the COB ID of the CAN frame is defined In the field Type the type of the CAN protocol used for each frame CAN 2 0A 11...

Page 21: ...onverter Document code MN67411_ENG Revision 2 101 Page 21 of 32 Example If we want to write the 64 Coil Status at address 10 Fig 7 we must send a CAN frame with COB ID 1383 0x567 and 8 byte of data Fi...

Page 22: ...sary In order to load the parameters or update the firmware in the Converter follow these instructions Connect the AC67400 to the PC Connect the CAN port of AC67400 to CAN port of HD67411 Feed the HD6...

Page 23: ...possible to load the created Configuration into the device and also the Firmware if is necessary using the USB port In order to load the parameters or update the firmware in the device follow these in...

Page 24: ...411 device Warning If the Fig 11 appears when you try to do the Update before require assistance try these points Check if the serial COM port selected is the correct one Check if the AC67400 is conne...

Page 25: ...ctronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN Modbus Master Converter Document code MN67411_ENG Revision 2 101 Page 25 of 32 MECHANIC...

Page 26: ...rial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN Modbus Master Converter Document code MN67411_ENG Revision 2 101 Page 26 of 32...

Page 27: ...rial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN Modbus Master Converter Document code MN67411_ENG Revision 2 101 Page 27 of 32...

Page 28: ...rial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN Modbus Master Converter Document code MN67411_ENG Revision 2 101 Page 28 of 32...

Page 29: ...ordering part number is formed by a valid combination of the following HD67411 E y z s d f Fixing lugs A Type 1 B Type 2 C Type 3 D without fixing lugs RS485 Termination Y Terminated with 220 N Not t...

Page 30: ...Rail DIN Power Supply 220 240V AC 50 60Hz 12 V AC Order Code AC34002 Rail DIN Power Supply 110V AC 50 60Hz 12 V AC Order Code AC67402 Cable Super Seal 1 5 MALE 2 pole 1 0 Meter Order Code AC67402 3 Ca...

Page 31: ...an countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applic...

Page 32: ...h to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information abo...

Reviews: