The means of the fields for “J1939” are:
In the field “
Baudrate
” the data rate of J1939 is defined;
In the field “
TimeOut Data
” a time is defined. When a J1939 message is not received in this time, the data on SNMP side are set to
0xFF;
If the field “
Enable Peer to Peer
” is checked, the gateway will mask the Source Address of the J1939 messages received.
In the field “
Device ID
” the ID of J1939 side of the converter is defined;
If the field “
Enable Not Standard Cancel Data
” is checked, the default value after the TimeOut Data will be the one defined on the right.