background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

M-Bus Wireless / Ethernet

 

 

Document code: MN67084_ENG     Revision 1.001   Page 1 of 22

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

 

User Manual 

Revision 1.001 
English 

 

M-Bus Wireless / Ethernet - 
Converter 

(Order Code:  HD67084-B2-169MHz-0, HD67084-B2-868MHz) 

 

For Website information:  

www.adfweb.com?Product=HD67084

   

 

For Price information: 

www.adfweb.com?Price=HD67083-B2-169MHz

  

www.adfweb.com?Price=HD67083-B2-868MHz

  

 

Benefits and Main Features: 

 

Very easy to configure 

 

Triple electrical isolation 

 

Temperature range: -40°C/85°C (-40°F/185°F) 

 

For others M-Bus products see also the following link: 

 

Converter M-Bus Wireless to  

www.adfweb.com?Product=HD67082

       

(Modbus Slave)

 

www.adfweb.com?Product=HD67083

       

(Modbus TCP Slave)

 

 
Converter M-Bus to  

www.adfweb.com?Product=HD67021

      

(RS232)

 

www.adfweb.com?Product=HD67022

      

(RS485)

 

 

Analyzer / Scanner /Sniffer M-Bus 

www.adfweb.com?Product=HD67031

 

 

Isolator/Repeater M-Bus 

www.adfweb.com?Product=HD67032M

 

 

Gateway M-Bus / Modbus RTU  

www.adfweb.com?Product=HD67029M-232

     

(on RS232) 

www.adfweb.com?Product=HD67029M-485

     

(on RS485)

 

 

Gateway M-Bus / Modbus TCP 

www.adfweb.com?Product=HD67044

 

 

Gateway M-Bus / PROFIBUS

 

www.adfweb.com?Product=HD67053M

 

 

Gateway M-Bus Concentrator 

www.adfweb.com?Product=HD67054M

 

 

Gateway M-Bus Slave / Modbus RTU master 

www.adfweb.com?Product=HD67059M-232

 

 

Do you have an your customer protocol? 

www.adfweb.com?Product=HD67003

 

 

Do you need to choose a device? do you want help? 

www.adfweb.com?Cmd=helpme

 

 

User Manual   

 

Summary of Contents for HD67084-B2-169MHz-0

Page 1: ...adfweb com Product HD67082 Modbus Slave www adfweb com Product HD67083 Modbus TCP Slave Converter M Bus to www adfweb com Product HD67021 RS232 www adfweb com Product HD67022 RS485 Analyzer Scanner Sn...

Page 2: ...ETURN POLICY 22 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To ob...

Page 3: ...evice can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual M Bus Wireless Ethernet Document code MN67084_ENG Revision 1 001 Page 4 of 22 EXAMPLE OF CONNECTION...

Page 5: ...dustrial Electronic Devices ADFweb com S r l User Manual M Bus Wireless Ethernet Document code MN67084_ENG Revision 1 001 Page 5 of 22 CONNECTION SCHEME Figure 1 Connection scheme for HD67084 B2 xxxMH...

Page 6: ...Ethernet and M Bus Possibility to filter the wM Bus meters to read Available wM Bus frequency 169 MHz or 868 MHz in relation to the order code Mountable on 35mm Rail DIN Wide power supply input range...

Page 7: ...ge 7 of 22 POWER SUPPLY The devices can be powered at 15 21V AC and 18 35V DC The consumption depends to the code of the device For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 15...

Page 8: ...with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used for uploading the Project and or Firmware For the op...

Page 9: ...LEDs are described in the table below LED Normal Mode Boot Mode 1 Device state green Blinks slowly 1Hz Blinks quickly 2 wM Bus comm green Blinks quickly when data on wM Bus arrives Blinks quickly 3 N...

Page 10: ...e should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to...

Page 11: ...runs with Windows called SW67084 It is downloadable from the site www adfweb com and its operation is described in this document this manual is referenced to the last version of the software present...

Page 12: ...iguration A device s configuration can also be imported or exported To clone the configurations of a Programmable M Bus Wireless Ethernet Converter in order to configure another device in the same man...

Page 13: ...the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible t...

Page 14: ...wM Bus Access See page 15 If the field Received Signal Strenght Indication is checked it is possible to add a byte at the end of the Ethernet frame to indicate the Strenght of the wM Bus signal dBm If...

Page 15: ...thernet In the field Manufacturer ID the Manufacturer ID of the wM Bus node is defined In the field Address the ID of the wM Bus node is defined In the field Version the version of the wM Bus node is...

Page 16: ...have to use this procedure Turn off the Device Put Dip2 of Dip Switch A at ON position Turn on the device Connect the Ethernet cable Insert the IP 192 168 2 205 Press the Ping button Device Found must...

Page 17: ...ted Note When you install a new version of the software if it is the first time it is better you do the update of the Firmware in the HD67084 device Note When you receive the device for the first time...

Page 18: ...ication and Link Quality Indication The frame sent by the wM Bus node is 44 A2 05 26 01 00 26 01 1B 7A F6 00 00 20 2F 2F 02 66 ED 00 01 FB 1B 2F 2F 2F 2F 2F 2F 2F hex The converter will send this Ethe...

Page 19: ...Electronic Devices ADFweb com S r l User Manual M Bus Wireless Ethernet Document code MN67084_ENG Revision 1 001 Page 19 of 22 MECHANICAL DIMENSIONS Figure 7 Mechanical dimensions scheme for HD67084...

Page 20: ...cy 169MHz M Bus Wireless communication 169 MHz 868MHz M Bus Wireless communication 868 MHz Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 4M 35mm DIN Rail mounting Device Family HD67...

Page 21: ...ion systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recy...

Page 22: ...do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to...

Reviews: