ADEXANO BACOBAN User Manual Download Page 1

25/01/2008 

 

                      IMP-4000.013A 

 

 

 

 

USER’S MANUAL FOR THE  BACOBAN® NEBULISING DEVICE 

(230V)

 

 
 
 

– PRESENTATION OF THE DEVICE 

 

 
  1 

– Power Cable 

  2 

– Drawer with fuse 

  3 

– Extra fuse 

  4 

– Used fuse 

  5 

– Switch for power On/Off 

  6 

– Handle 

  7 

– Button / diffuser head 

  8 

– Diffuser Head 

  9 

– Bottle  

10 

– Button to activate the spray, “Start /on “    

        button 
11 

– Jet 

12 

– Filtering foam pad 

13 

–  Dosing Selector  

 

Characteristics 

Power   

 

      

1000 W 

Voltage        

 

               230 V mono+T 

Frequency 

 

      

 50 to 60 Hz 

Intensity  

       

 

4,5 A 

Maximum  Intensity  

       

10 A 

Speed of rotation of the turbine 

22000 rpm 

Capacity of the reservoir   

0,5 or 1 liter 

Full weight 

 

  

6,5 kg 

Non laden  weight (without liquid or bottle) 5,8 kg 
Operating temperature 

 

5°  to 35°C 

 

Performances 

Exit speed of the air                         80 m/s 
Droplet size                  

              5 microns 

Maximal volume to be treated         500 m3 
Average output of the liquid             1000 ml/h 

 

II 

–  PRECAUTIONS FOR USE  

 

 

The  manufacturer  accepts no responsibility  for any material or physical incident  which occurs due to incorrect  or abnormal 
use of the device as indicated in the non restrictive list below: 
 -  Use with products other  than those within the  Adexano® range. 
 -  Ensure that electric power matches designated  standards 
 -  Introduce an object or liquid other than Bacoban into the device at any time   
 -  Move  the device conatining BACOBAN® when it contains product . The device should be  moved in a horizontal mode.  
-  Not to check the presence of the jet 

(11)

 

 
 
 -  Not to remove the bottle of the BACOBAN® for transportation 
 
The device diffuses a chemical substance, therefore it is necessary to pay attention : 
 - Not to inhale the product 
 - Not to smoke near the BACOBAN® while it is working 
 - Not to place  it near a source of ignition 
 - Humans or animals should not  be located in the room during the diffusion process. 

 

 

Reviews: