Summary of Contents for Vista-20HW

Page 1: ...VISTA 20HW 2 PARTITIONED SECURITY SYSTEM INSTALLATION INSTRUCTIONS Principal changes in this issue are indicated by margin lines N7526 2V14 96 Previous Menu...

Page 2: ...19 Entering Program Mode 19 Programming a Data Field 19 Reviewing a Data Field Erasing an Entry in a Data Field 20 Interactive Mode Programming 56 80 81 and 82 20 Loa ng Facto Defaults 2O Programming...

Page 3: ...nnections 44 Programming For External Sounders 45 Testing the Somder 46 LONG RANGE 10 47 General Itiormation 47 Connection 47 Progmming 47 REMOTE KEYSWITCH 48 Installing the Keystitch 48 Remote Keyswi...

Page 4: ...r Code 84 Master Code 84 Secondary User Codes 84 Keypad Functions 85 General Information 85 Arming Functions 85 Summary of bing Modes 85 Panic Keys 85 Relay Powerline Carrier Devices if used 86 4285 M...

Page 5: ...tions to Zone 8 23 Figure 10 Wiring Comection 4219 4229 4229 shown 27 Figure 11 4229 Connections To Control 32 Figure 12 4204 Connections To Control 32 Figure 13 4300 Transformer Wiring Connections 33...

Page 6: ...ese devices Each of the sections covering the installation of peripheral devices includes the programming for that device Without an understanding of the programming of the system you will not be able...

Page 7: ...le hnebox Many system options are programmed in an interactive mode by responding to Alpha keypad dmplay prompts These prompts are shown in a OO When programming the system data fields are indicated b...

Page 8: ...very bedroom where someone sleeps with the door partly or completely closed Smoke could be blocked by the closed door Also an alarm in the hallway outside may not wake up the sleeper if the door is cl...

Page 9: ...option for fast 10 15 msec re sponse on loop A fist expansion zone Provides the ability to control two separate areas independently each area functioning as if it had its own separate control each wi...

Page 10: ...nal Output Relays and Powerline Carrier Devices X 1O type Up to 4 relays using one 4204 Relay Module Up to 2 relays using one 4229 Zone Relay Module Up to 8 Powerline Carrier devices you must subtract...

Page 11: ...for protection This output interrupts for smoke detector reset if 4 wire smoke detectors are used progralmnin Prograrqmed options are stored in electrically erasable non volatile EEROM memory informa...

Page 12: ...ded at the back of the cabinet Installing the Lock if used Use an Ademco No N6277 Cam Retainer Clip Note The cabinet can be closed screws in the cover s edge Lock and No N6277 1 Push On Clip and secur...

Page 13: ...in Fig 2 2 Insert the top of the circuit board into the slots at the top of the cabinet Make sure that the board rests on the correct row see Detail A 3 Swing the base of the board into the mounting c...

Page 14: ...E F ure 3 Telephone be Connections Wwing The AC Transformer 1321 TF2 Wire the 132UTF2 transformer to terminals 1 and 2 on the control board See wiring table below for wire gauge to use Caution must be...

Page 15: ...ch Red and Black wires on the battery connector cable as follows a Red to the positive battery terminal on the control board see Summary of Connections Diagram for location if necessary b Black to the...

Page 16: ...ring to the wiring length gauge chart below Wire lengths gauge for Partition 2 keypads should be determined separately from those keypads connected to Partition 1 2 Run field wiring from the control t...

Page 17: ...er to the instructions provided with the keypad for mounting procedure You can either surface mount or flush mount keypads using an appropriate Trim Ring Kit 5137TRK or 6139 TRK Refer to the mounting...

Page 18: ...lpha keypads or dl Fixed word keypads will be displayed After approximately 1 minute the green READY LED or POWER LED on some types of keypads should light and the word READY Fixed word keypads or DIS...

Page 19: ...teractive programming is used for programming zone information programming relay outputs and for learning transmitter serial numbers Programming can also be performed remotely from the installer s off...

Page 20: ...mber 56 Zone Programming Zone characteristics report codes alpha descriptors and serial numbers 8O Relay Programming 4229 or 4204 Relay modules or Powerline Carrier devices 81 Zone List Programming Zo...

Page 21: ...High Resistan ce Supervision on Hard WA Zones 2 S Special supervision in the control senses high resistance on hard wired zone loops 2 8 causing a warning CHECK display with the tiected zone number t...

Page 22: ...tionductdetect wiDH400base SystemSensor1451DH r 1 2 WIRE SMOKE UJ z L J IN ULINSTALLATIONS ONLY ZONE 1 MAY BE USEO FOR FIRE Figure 7 2 Wine Smoke Detector Connected to Zone 1 Wdng 4 W SmokdCombuetion...

Page 23: ...code OFF clears the memory of alarm and resets the glassbreak detector 1 Connect all detectors in parallel across zone 8 terminals 19 and 20 Compatible Glass Break Detectors Use detectors that meet t...

Page 24: ...ting with zone 2 enter 02 Press to continue A summary display will appear showing the present status of that zone s programming Zn zone number ZT zone type P partition to which zone is assigned RC rep...

Page 25: ...wing the data for the zone that was just programmed If It M programmed satisfactorily press to ml The next request is to enter Alpha descriptors for the zones The entry may be done now enter 1 or may...

Page 26: ...d zone s as necessary also make sure that you have connected a 2000 ohm EOL resistor across the terminals of unused zones When the DISARMED READY TO ARM message is displayed you can proceed to the nex...

Page 27: ...nd zone 09 if a zone expander is disconnected Units have tamper protection for security when mounted outside of the cabinet Assign zone numbers 10 17 for the eight wired expansion loops designated A t...

Page 28: ...pear showing the present status of that zone s programming Zn zone numbe ZT zone pw P partition to which zone is assigned RC report code for that zone In input type of zone AW for Aux Wired L Loop not...

Page 29: ...e next prompt For all zone types the next request is to enter Alpha descriptors for the zones The entry may be done now enter 1 or maybe done at a later time usin 82 interactive mode enter O We recomm...

Page 30: ...ve comected a 1000 ohm EOL resistor across the terminals of unused expansion zones on the 4219 or 4229 module When the READY TO ARM message is displayed you can proceed to the next step Fault and rest...

Page 31: ...refore if using Powerline Carrier Devices a 4300 transformer must be used in place of the regular system transformer In 8O and 81 interactive modes a series of keypad prompts will request entries for...

Page 32: ...arrier LL DATA IN FROM CONTROL term T Bti GROUND tmm4 OATA OUT TO CONTROL term 6 RED 12V tWII 5 Figure 12 4204 Connection to Control devices The 4300 transformer provides AC power to the control panel...

Page 33: ...ct the other end of the 3 conductor cable to the 4300 transformer as indicated in the table below and in the diagram that follows 4300 TRANSFORMER WIRE CONNECTIONS 4300 TERMINAL ITO IX AL ON CONTROL 1...

Page 34: ...evice These conditions apply only when a zone list is used The different choices for EVENT are listed below and in the Programming Output Relays Powerline Carrier devices section that follows w ALARM...

Page 35: ...when all the zones in that list restore from a previous fault trouble or alarm condition This will occur regardless of what is programmed to START the device therefore a RESTORE ZONE LIST would norma...

Page 36: ...or 02 for a 4229 or 01 02 03 or 04 for a 4204 or 01 08 for Powerline Carrier 01 devices or 00 to end these entries Press the I key to continue The key is used to accept an entry and advance to the nex...

Page 37: ...n number 1 or 2 or Ofor any Press the I key to continue This screen again displays a summary of the current device START programming Press the key to continue This screen again displays a summary of t...

Page 38: ...In the following displays zone list 01 has been selected for programming Enter each zone number to add to the zone list by first entering the zone number then the key example 01 02 03 After all zones...

Page 39: ...ne as confirmation after any command is entered The phone used for phone access must have Touch tone capability though Touch tone service is not necessary if premises uses PULSE dialing switchable pho...

Page 40: ...sing the connector cable supplied with the 4285 see Figure 16 These are the same connections as those usedfor remotekeypads connectedto Partition1 YELLOW I DATAOUT terminal7 2 Insert the keyed connect...

Page 41: ...the control terminals Otherwise an error signal fast busy signal will occur when trying to access the system fkom an on premises phone If the telephone system on the premisesincludes a Caller ID unit...

Page 42: ...accordingly Voice Answering Module Machine Downloading Field 95 Programming Yes No No Setfor valueotherthan O 1 15 Thiswill enablethe control panelto answerthephonecall Otherwise it will not be possib...

Page 43: ...des an answering machine the 2 digit phone code should be entered during a pause at the beginning of or during the outgoing answering machine message When the 2 digit phone code is entered the caller...

Page 44: ...built in Indoor Siren for indoor wall mount 747F available for flush mounting Ademco 747UL Self contained siren driver built in for indoor Indoor Siren wall mount UL Listed Ademco 744 6 jumper selecte...

Page 45: ...the Partition 1 keypad terminals on the control power up the system temporarily If you had previously comected the AC transformer to the control panel you need only plug in the transformer to 120VAC...

Page 46: ...installer code 4112 and press the TEST 5 key on the keypad The external sounder should sound for 1 second if the sounder is good and proper connections have been made Note that if the backup battery i...

Page 47: ...Long Range Radio to the control s keypad connection points terminals 4 5 6 and 7 as shown below BL4CK o RED 5 0 GREEN 7720PLUS17S20 6 LONG RANGE RADIO o YELLow 7 CONTROL TERMINALS Figure 16 Long Rang...

Page 48: ...ect the 4146 keyswitchs normally open momentary switch to zone 7 terminals 18 and 19 Remove the 2000 ohm EOL resistor if connected across zone 7 terminals 2 3 4 Connect the Red and Green LEDs to pins...

Page 49: ...Keyswitcb Whing 4300 Interface Transformer not used r 1 I 1 123456789 9 PIN CONNECTOR ON CONTROL BOARD g f g g g g g m m m a BROKEN LINES REPRESENT INSTALLER WIRING CONNECTIONS c 4142TR CABLE L f k A...

Page 50: ...prompt will be displayed Enter zone number 07 if not already present Following this entry press to continue A summary display will appear showing the present status of zone 7 s programming Zn zone num...

Page 51: ...riptor for zone 7 Since this is a keyswitch zone no descriptor is required Enter O If O no was entered above the system will display a prompt for entry of the number for the next zone Press 01 01plus...

Page 52: ...this time all sirens and all continuous keypad sounds in all partitions will be shut off W Connections The method used to trigger AAV is via the use of a 4204 or 4229 relay module as shown in the AAV...

Page 53: ...R I III l REUY1 SNOWN NOTE 00 NOT USE REIAY 1 R ANY OTNER WRFQSE I ure 18 Connection Of AAV Unit When Not Using A 42S5 VIP Module 1 4 1 NOTE 00 NOT USE RELAY 1 FOR ANY oTHER PURPOSE Figure 19 Connecti...

Page 54: ...edwitha READY LEDin placeof a POWER LED After approximately 1 minute the initial displays will revert to DISARMED READY TO ARM for Alpha keypads or READY for Fixed word keypads if there are no faulted...

Page 55: ...matically approximately every four hours and if it cannot sustain a load a low battery message is displayed and if so programmed will be reported to the central station AUXILIARY DEVICE CURRENT DRAW W...

Page 56: ...lowing page In addition up to 5 installer defined words can be added to those already in memory Thus when an alarm or trouble occurs in a zone an appropriate description for that zone s location will...

Page 57: ...ins a flashing cursor which signifies the entry mode To delete or change the default descriptor for zone 1 press plus the same zone number 01 This will clear that descriptor and gain access to the ent...

Page 58: ...press O J at the summary display This prompt will be displayed Press O This will be displayed Press 99 to exit the programming mode Alternate Method For Programmiog Zone Descriptors 1 Performsteps1 t...

Page 59: ...or example if you are creating the first custom word or word string enter 1 for the second enter 2 etc A cursor will now appear at the beginning of the second line One of two methods of entering the c...

Page 60: ...1 182 183 184 185 186 187 188 189 190 191 192 193 SONIC SONS SOUTH SPRINKLER STAMP STATION STEREO STORE STORAGE MEDICINE MICROWAVE MONEY MONITOR E S MOTOR 226 227 z 230 231 232 0 i 023 BOITOM 024 BOX...

Page 61: ...el the panel will not send its message Once the handshake frequency is received and understood by the panel the panel will send its message If there is an error in the transmission the receiver does n...

Page 62: ...2 Alarm SSS S A SSS S A Ssss M AAA A Z Trouble SSS S T SSS S T Ssss Tt TM T t Bypass SSS S B SSS S B SSSSBb BBB B b AC LOSS SSS S E SSS S E SSSSE EEE E Ac LowBatt SSS S L SSS S L SSSSLLB LLL L LB Ope...

Page 63: ...1 Duress 122 Alarm 24 hour Silent 123 Alarm 24 hour Audible I 131 IAlarm Perimeter I 132 Alarm Interior 134 Alarm Entry Exit 135 Alarm Dav Ni ht 143 Alarm Expansion Module 146 Silent Burglary I 150 IA...

Page 64: ...Press 43 Press 44 Press 45 Press 46 PRIMARY PHONE No 11111111111 Enter up to 12 digits If fewer than 12 digits entered exit by pressing and next field number e g 42 To clear entries from field press 4...

Page 65: ...ort only This is the default Press 50 Press 51 Press 52 Press 53 TO PRIMARY TO SECONDARY 1 Alarms Restore Cancel Others 2 All except Open Close Test Open Close Test 3 Alarms Restore Cancel All 4 All e...

Page 66: ...Entries in the second boxes will be ignored For system status non alarm codes enter a 1 in the first box for all the system conditions you want to send to the central station An entry of O in the firs...

Page 67: ...reporting ALARM RESTORE REPORT CODE 1st DIGIT u This is sent when the zone that caused an alarm is restored to its non faulted condition 2nd digit is automatically sent as the 2nd digit of the zone a...

Page 68: ...P Press 93 NUMBER OF REPORTS IN ARMED PERIOD O limits reports to a total of 10 per code 1 allows an unlimited number of al plus alarm restore reports Defaultis O Enter 1 for UL installations Press 94...

Page 69: ...e place and where more time might be needed to get to and from the keypad typically used for a garage loading dock or basement door This zone type gives an instant alarm if the zone is faulted when th...

Page 70: ...any zone in a wired zone expansion module or wireless zones When used with zone 1 on the panel 2 wire smoke detectors can be used For an explanation of the verification function refer to the Operation...

Page 71: ...ng the system Enter Ofor disabled or 1 for enabled for each partition Default is O FORCED BYPASS FUNCTION Partition1 Partition2 This feature allows sll faulted zones to be bypassed automatically All z...

Page 72: ...sible for programming If the 4146 keyswitch is used with only Red and Green LEDs comected no lock switch and tamper switch to simply provide an arming ready status indicator panel zone 7 can then be u...

Page 73: ...eded to access an outside line If fewer than 4 digits are needed to be entered exit by pressing and next field number e g 41 To clear entries horn field press 0 PRIMARY PHONE No SeeBox at Left 1111111...

Page 74: ...larm restore reports during one armed period is determined by field 93 SPLIT DUAL REPORTING u Enter Oto disable Backup report only This is the default w TO PRIMARY TO SECONDARY 1 Alarms Restore Cancel...

Page 75: ...in which the system responds to faults in that zone Enter the zone type code or change it if necessary Zone types are 00 NotUsed 06 24Hr Silent 10 Interiorw Delay 01 Entry Exit 1 07 24HrAudible 23 No...

Page 76: ...it but retain all data 1I Yes O NO II except the ori nal zone type You can then go back to this zone later and put back an active Zone Type to re enable it TO PROGRAM SYSTEM STATUS AND RESTORE REPORT...

Page 77: ...messagewill contain the zonenumbersnd errorcode374 Troubl Exit Error to definethe alarm as an Exit Error ratherthanE E or Interior If 4 2 formatis used the digitenteredin this fieldwill be sent follo...

Page 78: ...ed OUTPUT DEVICES This is an interactive menu mode that is applicable only if field 25 is w programmed for a 4229 or 4204 or if Powerline Carrier devices are to be used See Section 7 REL4Y OUTPUTS POW...

Page 79: ...ons the AAV option must be disabled enter o I 92 PHONE LINE MONITOR ENABLE u O Not used default 1 Localkeypaddisplayonlywhenphonelineis faulted 2 Localkeypaddisplaypluskeypadtroublesoundwhenlineis fau...

Page 80: ...he answering machine is turned off and does not answer the phone call Yes No Yes Set for value other than O 1 15 Yes Yes Yes Enter 15 to bypass answering machine No No No Enter O No Yes No Enter O No...

Page 81: ...evice tapped into the phone line to take over communication and substitute system compromising information Equipment Required At the premises VISTA 20H Wandkeypad At the installer s office home An IBM...

Page 82: ...cation is terminated The detailed operation of the download functions is covered in the installation instructions for the V LINK Downloading Software Diskette Remote Programming Advisory Notes Alarm a...

Page 83: ...y enteringthe code and pressingOFF CheckEntry Exitdelayzones 4 Check the keypad initiatedalarms that are in the system by pressingthe Panickey keypairson somekeypads If the systemhas been programmed f...

Page 84: ...ove secondary codes from the system individually To assign or change a Secondaqy security code enter via partition s keypad Partition s Master Code CODE key User 03 16 desired Secondary Code I Notes T...

Page 85: ...on and 3 panic key pairs or individual panickeys depending onkeypadtype seePanic Keys forsilent audible fireorpersonalemergency alarms Thesekeyscannoti the central stationofan alarmcondition if that s...

Page 86: ...ecurity Code 7 Device activates starts that device Security Code 8 Device de activates stops that device Refer to the separate instructions supplied with the 4285 module for information concerning its...

Page 87: ...ring and DIP switch settings on the units A display of RAT Fixed word keypads or SYSTEM LO BAT Alpha keypads with no zone number indicates that the system smainstandby batteryis weak Telephone Line Fa...

Page 88: ...4a Check with all occupants of protected home 4b Check setting of entry delay Exit delay is 40 seconds longer than the entry delay time Remind user of same 4c Check all openings for proper switch and...

Page 89: ...it easier for us to serve you quickly and effectively You may contact Technical Support via Toll Free FAX Please include your return FAX number You will receive a reply within 24 hours You may also c...

Page 90: ...art 68 STATEMENT This equipmentcomplieswithPart 68 of the FCC rules On the front coverof this equipmentis a label that contains amongotherinformation the FCC registrationnumber and ringer equivalencen...

Page 91: ...Reporting 10 characters see DTMF TouchTone DataTones 1400 2300Hz ACK 1400Hz KISSOFF Ademco Low Speed 10 pulses see 1900HzDataTone 1400Hz ACWKISSOFF Radionics SESCOA 20 pulseshec 1800HzData Tone 2300H...

Page 92: ...Voltage Input 12VDC Current Drain 35rnA 3 Interface Wiring Sameas 4127 4 8 EOLR LOOPS A H LoopA canbe set forfast 10 15msec responseto an open 1 Physicak 6 1 2 W x 4 1 4 H x l 1 4 D 169mm x 108mm x 3...

Page 93: ...r built in for indoor wall mount UL Listed 6 jumper selected sound outputs Rated at l19dB with use of an 8 ohm 30 watt speaker Voice siren driver with English Spanish and French voice messages Separat...

Page 94: ...4 28 36 42 45 47 92 6139TRK 17 702 93 705 820 93 713 93 719 93 74 44 93 745x3 u 93 747 93 m 747UL 44 93 7720 PIUS 10 47 9 Pin Connector 48 A A77 716B 23 93 AB 12M 10 Motorized Bell Box 44 93 AC Loss R...

Page 95: ...Exit Alarm Exit Delay 69 88 Exit Error Report Code 66 77 Exit Programming Mode 80 Expanded or 4 2 Format 66 76 External Sounders 44 F Facto Defaults 2O Fast Busy 5gnal 41 61 87 FC FCC 90 Fire Alarm S...

Page 96: ...D 54 Relay Outputs 31 Relay Programming 20 Relays 31 Remote Keypads 9 Remote Programming 81 Report Code 75 77 Report Code Formats 61 Report Codes 66 76 Report Format 74 Report Format Primary Secondary...

Page 97: ...Detectors 21 Wiring 4 Wire Smoke Combustion Detectors On Zones 2 7 22 Wiring Length Gauge Chart 16 Wiring Table 14 Word Stting 59 Worksheet 55 x X 10 also see PowerLine Carrier Devices 31 37 z Zone A...

Page 98: ...walls ceilings floors closed doors glass partitions glassdoors or windows Mechanicaltampering masking paintingor sprayingof any materialon the mirrors windowsor any part of the opticalsystemcanreducet...

Page 99: ...ii ii l Figure 20 VISTA 20HWSUMMARY OFCONNECTIONS 99...

Page 100: ...AL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE...