K3644 12/99
5804BDE
TWO-WAY WIRELESS KEY
USER GUIDE
About the 5804BDE
The 5804BDE is a four-button remote control for your alarm system. It can send a command to the alarm system, such as to arm or disarm,
as well as receive system status. Two LEDs and a speaker indicate system status. The 5804BDE is typically used for arming, disarming, and
home automation. Check with your installer to understand which functions the buttons have been assigned on your unit.
Operating the Buttons
Activating a Function
To activate a function, press and hold the appropriate button down until the yellow LED flashes (2 beeps will be heard), and then release it.
Requesting System Status
You can check system status before arming or disarming your system.
Check your system status by momentarily pressing and releasing any button. The yellow LED will flash after you release the button (1 beep
will be heard). After a second or two, the 5804BDE will display the system status through the LEDs and speaker (see the System Status
Indications Table, below). If the 5804BDE does not receive system status from the panel for approximately 5 seconds, it will generate a long
(1 second) beep and shut itself down. It will also shut itself down if you do not press a button within 5 seconds of receiving a status update
.
System Status Indications Table
LED
LED Condition
Sounds
System Status
On Steady
2 Beeps
Armed Away or Maximum
On Steady
3 Beeps
Armed Stay or Instant
Flashing
Pulsing
Fire Alarm in progress
Flashing
Steady
Armed, Burglary Alarm in progress
Red
Flashing
Silent
Alarm Memory
Green
On Steady
1 Beep
Disarmed, Ready to Arm
Yellow (right)
Flashing
—
Indicates RF transmission (non encrypted)
Yellow (left)
Flashing
—
Indicates RF transmission (encrypted)
In Enter House ID Mode
Red & Green
Alternately Flashing
—
In Enable or Disable High-Security (encrypted) Mode
System Trouble
Green
Flashing
1 Beep
System Not Ready
Multiple Button Operations
The 5804BDE can generate the same responses as keypad
panic key pairs of [*] + [#] and [*] + [1] by depressing “A” + “C”
and “B” + “D” button pairs, respectively. You must depress the
button pair for at least 2 seconds for the 5804BDE to recognize
the button pair command. These button pairs allow you to
activate panic, fire, and medical alarms depending on control
panel programming
.