Summary of Contents for 4140XMP

Page 1: ...vwrLYA SERIES 4140XMP INSTALLATION INSTRUCTIONS NSOtM 1Vl 1192...

Page 2: ...mAp m E S T West Coast Technical Support l 800 458 9469 8 a m 5 p m P S T P E Before you call Technical Support be sure you l Check all wiring connections l Determine that the power supply and or back...

Page 3: ...er 18 B Up Power 16 Btittery Standby Table 16 Earth Ground Connections 16 Power Up Procedure 16 Polling Loop Current Draw Worksheet 18 Auxiliary Device Current Draw Worksheet 1 8 V SYSTEM OPERATION I7...

Page 4: ...OWERINGTHE SYSTEM q STEP 4 Learn how the system operates including security codes keypad functions trouble conditions and how to set the real time clock by reading section V SYSTEM OPERATION STEP 5 lt...

Page 5: ...the panel s terminal block Supports latching type P wire glass break detectors on zone 6 Supports up to 16 smoke detectors on zone 1 Up to 70 user security codes can be programmed Choice of normal rl...

Page 6: ...an entry exit delay zone was faulted first BASIC 9 HARD WIRED ZONES ZONE 1 This zone has a 350 millisecond response and can be assigned to any zone type and is set up for EOLR supervision only This z...

Page 7: ...um allowable current draw on the polling loop is 64mA Refer to the POLLING LOOP CURRENT DRAW WORKSHEET found in the POWERING THE SYSTEM section for current draws of various polling loop devices If mor...

Page 8: ...LE will be displayed depending on the response programmed for zones 88 8 90 fields 1 08 8 1 09 HOUSE IDENTIFICATION The 4280 responds only to transmitters with the same house ID DIP switch programmabl...

Page 9: ...will transmit ono6 every 12 seconds while ti zone is faulted Tmnsmitters 6et for zones 56 63 will transmit once every 3 seconds while faulted These two ranges of zone numbers could adversely affect tr...

Page 10: ...al consoles may be connected to separate wire runs The maximum wire run length from the panel to a console which is homerun bade to the panel must not exceed CONSOLEWIRELENGTHS NOTE The length of all...

Page 11: ...e for zones 48 55 Built in 85 dB piezoelectrii alarm sounder and audible bw battery warning IR M6TCbN UtItmS Select a mounting site wlth the following notes in mind Best coverage will be obtained if t...

Page 12: ...De activated 1K Ohms to Ground An optional 675 Ground Start module can be used for installations having telephone lines which require ground start instead of loop start operation to obtain dial tone...

Page 13: ...er or not LED lndlcatlons are deflned es follows zones 2 6 are 98leCted to use EOL resistors See diagram GREEN RED 1MEANING below GF oFF I DISARMED 8 NOT READY A momentary short across this zone will...

Page 14: ...n Figure 7 MOUNTING THE PC BOARD MOUNTING THE 4146XMP LOCK 1 Remove the lock knockout on the control cabinet cover Insert the key into the to Position the lock in the hole making certain that the latc...

Page 15: ...vided to mark the cut out straight lighten each clip screw making sure that the 2 Insert the four l 1 2 long 6 screws through the attached clii slides down into Is guide track mounting holes in the Tr...

Page 16: ...be effective the designated earth ground r7 terminal must be terminated in a good earth ground The following are examples of good earth grounds available at most installations Metal Cold Water Plpe Us...

Page 17: ...sign up to 68 temporary codes which can be used by Range Radio note that duress is signalled on the same secondary users of the system who do not have a need to trigger that signals silent panic where...

Page 18: ...ONDS USlNG THE BUILT IN USER S GUIDE 5137 only An abbreviated User s Manual is stored in the system s memory and can be particularly useful to the end user il the r printed User s Manual is not conven...

Page 19: ...rating RECALLING ALARM TROUBLE MESSAGES Memorv of Alarm The system s alarm memory retains all events for a period of 10 days starting at the time of the first event Upon expiration of the lo day perio...

Page 20: ...akes a report to reach the central station An average 4 2 Low Speed report might take as long as 20 seconds to complete its report but 4 2 Express takes under 3 seconds Two message rounds are eliminat...

Page 21: ...ceiver contact Ademco s Technical Support group at 1 800 645 7492 4140XMP COMMUNICATION PR Contact ID selects 4 1 or 4 2 OGRAMMING GUIDE Hlgh Speed Express No eflecf No effect 4 I No effect No effect...

Page 22: ...ew the contents of a data fleld press I plus the 2 digit field address The field s entries will be displayed but no changes to these entries can be made In case of errors If an address is improperly e...

Page 23: ...to cftannels and then channels to codes ff programming communication fields manually simpty enter whatever code 3 1 4 1 4 2 or Ademco Express is to be sent for each zone including panics non alarm co...

Page 24: ...n this example V Then press key S to display the first availabfe word beginning with D Press key 3 repeatedly until the desired word DOOR appears To accept the word press the S key whiih again toggles...

Page 25: ...24 hour Auxilii 00 I Fm 10 I Inldor Delsy r 05 I Day Night I DESIGNATE RIGHT LOOP FOR MULTIPLEX l06noooona ZCNES 10 11 12 13 14 15 16 as 33 34 I 36 37 36 38 40 l O7 cl Cl cl cl cl cl Cl cl l cl Cl cl...

Page 26: ...diel PRIMARY FORMAT Cl 1l34 IbLwSpeuf l cQntaaD 2ddema h wd 3 AdemmExmm LOW SPEED FORMAT Pkwy cl fOANmm LW Speed l es ibdionic3 52 SECONDARY FORMAT cl tUOWspeedl l D 2ddemso hSpeed 3ddemcDExpeas LOW...

Page 27: ...1 37 1 421 I I 4il 44ri l 56L I J l l 59 71 I 647 lil 6477 I 3611 I 39 11 I T J 401 l i l NON ALARM CODES 461 I 1 47 17 461 I I J I 11 ALARM REPORT CODE ID DIG 77 ID I I I I I 1 I I Nuw NUw0 01 NUF N...

Page 28: ...emcok Contact ID 0 To change to next set of program fields press 94 9 To return to prevlous 8at of fields press 99 l To erase account phone number field entrles press I field number I l To asslgn zone...

Page 29: ...tar The 6 key is used to move the 7 Press the I key to return to the l ZN display To cursor to the right and the 4 key to move the cursor to confirm that the new message has been stored in memory pres...

Page 30: ...swers at the pre programmed ring count and executes a handshake with the computer 3 The computer sends a request for call back to the Control unless call back is not required 4 The panel acknowledges...

Page 31: ...RE Alpha consoles or FC Fixed Word consoles indicates a failure to communicate no Klssoff by the receiver at the central station after the maximum number of transmission attempts is tried H this otxur...

Page 32: ...ONES l 9 Zone 1 In trOUbl8 CHECK l lf programmed for fire or burglary using open circuit sensors a 2 000 ohm EOLR must be used across the zone at the last device as described in the SYSTEM CONFIGURATI...

Page 33: ...sminers have fresh batteries 97 appears In tha conaofo dlaplay and rapld boeplng occurs l This indicates that the polling loop has either a direct short or a short to ground on the side Miht also indi...

Page 34: ...his b ion heck programLfield 3Q for e h TouchTone or rotary dialing In most cases if rotary is selected dialing will be successful but ff TouchTone is selected than the line i must be a i a Tone line...

Page 35: ...ELLOW Data Out BLACK Ground and connection from supplementary power supply 4i90wH OPERATION WRING DIAGHAM The 4190WH is a P zone known as left and right loops JUMPERS RPM The left 1000 can be used for...

Page 36: ...32 P...

Page 37: ...S TO TABLES A 6 B SHOWN SET FOR ID 10 RESPONSE TIME t IMPORTANT USE ID 31 FOR APPLICATIONS NOT REOUIRING ADDRESSABLE CONSOLES WITMTABLE A 8 VIEW POS 1 MUST SE dn UP m THIS TABLE FOR DIPS THIS TABLE FO...

Page 38: ...EVICES 4275 PIR 4278 PIR 4194 Reed Contact SIIOWN SET FOR ID 10 UP IA dn 8 D INST MODE On IA UP 181 E PULSE COUNT dn D INSTANT MODE POS 7 UP Al dn 8 WALK TEST POS 8 UP WKOISABLE Pn A UP 8 WIT DISABLE...

Page 39: ...ersal Xmtr 5711 5711 WM Door Window Transmitter TERMINAL e BLOCK SIDE VlEw OS 1 UP I NORMAL RESPONSE XMTR ID bn s FAST RESPONSE WSCKMN POS 12 g Eg QS 2 UP I NO COVER TAMPER Avoid IO 32 i wtth N O 1 dn...

Page 40: ...l cl Cl ZONES 10 11 12 13 14 15 16 ZDNS 33 34 35 36 37 35 39 40 luIlKKlclcl0clI 1 2clclno cloclcl MtEs 25 26 27 28 29 30 31 32 doEES 40 50 51 52 53 54 55 i6 24 419OWHTAMPER DISABLE q lmame 1 1 13cl q...

Page 41: ...f dm DIAl TONE PAUSE cl 51 bQuand4 l llwapnQ 2aOr mQ be9 u DlALTONEDRECTK N cl lllrairbr8uelwmno omp w mondbt PRIMARY FORMAT El 1 34 P S W MonmctD WdemcoHigtrSpnd Eapmas LOW SPEED FORMAT Primary cl bA...

Page 42: ...gg 3311F 41 i I I w L 1 I 1 I 3411 I 4217 7 _ 7 s deiautt to 001 E 65ID l66 CODE 67 ID 68 l69 CODE 70 ID 71 CODE 72 ID 73 If i l l il k nn 491 ri l 571 ri l IL I I J 361 I 371 IT 1 381 I 391 lil 40 m...

Page 43: ...emco H h Speed ES Ademco s Contact ID l To change to next set of program fields press 94 l To return to previous set of fields press 99 l To erase account 81phone number field entries press I field nu...

Page 44: ...10 I t 010 ITrouble 191 013 I I 010 I 61 CODE 62 ID H 010 olo Lola L lo 65 ID 67 ID 69 CODE 491oJi 5o J 5l altj I 66 CODE AbmnRaL Tmubb TVWht 70 ID I 010 Io o lolo ml I I I 010 I 441 013 I I 010 I I 0...

Page 45: ...1013 3110 3 pjq 8pl fTq 16 m 24wjm 32 013 11 ALARM REPORT CODE 6 ID DIGITS FOR ZONES 3344 6 SUPERVISORY RESTORE COD 64 CODE l65 ID 66CODE 67lD 68 69 CODE 70 ID 71 CODE l72 ID 33 0131 piiq 41 0 4 fxyq...

Page 46: ...51 012 I I 010 I 131 013 I I 010 I I OIO I Rat 211 014 I I 010 I 1 5 14pF l rJ 15 013 EJ lSf73 m I 1 I I I t REP R1 CODE 6 ID dIGITS FOR ZONES 33 64 i i 66CODE 67 ID 66 1 i I I 010 I 411 015 I I 010...

Page 47: ...M REPORT CODE ID DIGITS FOR ZONES 33 64 6 SUPERVISORY RESTORE C0D E l64CODE 65 ID 66 CODE 67 ID 66 69 CODE 70 ID 71 CODE 72 ID 33101 II 41 1 1I fTiq Iolr AlarmRst 49 pqE 57pq piq pj7 AlamlRsr T l r j...

Page 48: ...er are on different branch circuits If necessary the user should consultthe dealer or an experienced radio televisiontechnician for additional suggestions The user or installer mayfind the followingbo...

Page 49: ...teriel est wnforme a certaines normes de protection d exploitation et de securite des reseaux de telecommunications Le ministbe n assure toutefois pas que le materiel fonctionnera a la satisfaction de...

Page 50: ...juryor death l Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation manual Passive Infrared Detectors do not provide volumetric ar...

Page 51: ...IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILRY WHATSOEVER EVEN...

Page 52: ...I __ I _I I _ ALARM DEVICE MANUFACTURING CO LDIVISllh cl PlTlV CnRDOR Io 165 Eileen Way Syosset New York 11791 Copyright 1991 PITTWAY CORPORATION n...