Telephone:
0117 923 5375
Fax:
0117 923 5374
Victoria Road, Avonmouth, Bristol BS11 9DB www.addvent.co.uk
ISSUE 1/0316
IMPORTANT SAFEGUARDS
WHEN USING ANY ELECTRICAL APPLIANCE, BASIC SAFETY
PRECAUTIONS SHOULD ALWAYS BE FOLLOWED.
PLEASE READ ALL INSTRUCTIONS CAREFULLY
AND RETAIN FOR FUTURE REFERENCE
ONE YEAR
EXCHANGE
1
Maintenance
Electrical Ratings
Model AVIK20W:
Ratings: 220-240V ~ 50/60Hz;
1 x 20W E-27 3U UV Energy Saving Lamp;
Model AVIK40W:
Ratings: 220-240V ~ 50Hz; 2500V max;
2 x 20W E-27 3U UV Energy Saving Lamp;
Specifications
AVIK20W and AVIK40W
Cleaning
Always disconnect the power before any
maintenance.
Slide out the collection tray to remove and throw
away the bodies of insects.
The body of the unit should only need occasional
wiping over with a damp cloth and mild
detergent.
.
Changing the lamps
Step 1
: Disconnect the power
Step 2:
Remove the collection tray to gain access
Step 3a:
Rotate the lamp anticlockwise, to remove
them.
Step 3b:
Install the new lamp by rotating the lamp
clockwise.
Step 4:
After replacing lamp, replace the
collection tray.
NOTE: if the Insect Killer is free-standing, remove the collection tray and turn the
unit upside down to gain access to the lamps.
AVIKW
Waste electrical products should not be disposed of with household waste. Please recycle where
facilities exist. Check with your local authority or retailer for recycling advice
AVIK20W and AVIK40W
Low Energy Insect Killers
Installation Instructions and User Guide
STEP 3a
STEP 3b
AVIK20W and AVIK40W
AVIKW[16]instructions 18/3/16 09:58 Page 1