background image

www.addi-data.com

Ethernet

Ethernet Port 0

Ethernet Port 1

Cable (green)

Pin No. Female connector, 

D-coded, M12

Female connector, 

D-coded, M12

Lead colour

1

TD0+

TD1+

yellow

2

RD0+

RD1+

white

3

TD0-

TD1-

orange

4

RD0-

RD1-

blue

Trigger/Synchro

Trigger/Sync In

Trigger/Sync Out

Cable (purple)

Pin No.

Connector,  

5-pin, M12

Female connector, 

5-pin, M12

Lead 

colour

Lead 

pair

1

Trigger input -

Trigger input -

blue

1

2

Trigger input +

Trigger input +

white

3

Synchro input +

Synchro

red

2

4

Synchro input -

Synchro output -

black

5

Ground

Ground

Pin assignment

Summary of Contents for MSX-E3701

Page 1: ...s Center Airport Boulevard B210 77836 Rheinmünster Germany Tel 49 7229 1847 0 Fax 49 7229 1847 200 info addi data com www addi data com 02 04 08 2014 QUICK INSTALLATION MSX E3701 and MSX E3700 Ethernet system for length measurement ...

Page 2: ...he Ethernet system D Connect the Ethernet system to the power source using a power supply cable e g CMX 20 E Check the status of the Ethernet system by means of the LED display Power On lights green Power supply is OK Port 0 ACT Link flashes yellow Ethernet cable is connected to Port 0 Port 1 ACT Link flashes yellow Ethernet cable is connected to Port 1 Status lights green Ethernet system is ready...

Page 3: ...ow 2 RD0 RD1 white 3 TD0 TD1 orange 4 RD0 RD1 blue Trigger Synchro Trigger Sync In Trigger Sync Out Cable purple Pin No Connector 5 pin M12 Female connector 5 pin M12 Lead colour Lead pair 1 Trigger input Trigger input blue 1 2 Trigger input Trigger input white 3 Synchro input Synchro output red 2 4 Synchro input Synchro output black 5 Ground Ground Pin assignment ...

Page 4: ...V 24 V white 3 Ground Ground blue 4 Ground Ground black 5 not connected not connected grey MSX E3700 Ethernet Ethernet Port 0 Ethernet Port 1 Pin No RJ45 connector Pin No RJ45 connector 1 TD0 9 TD1 2 TD0 10 TD1 3 RD0 11 RD1 4 not connected 12 not connected 5 not connected 13 not connected 6 RD0 14 RD1 7 not connected 15 not connected 8 not connected 16 not connected ...

Page 5: ...1 mm grid 3 pin terminal 3 81 mm grid Note 1 Trigger input Synchro In Twisted pair 2 Trigger input Synchro Out 3 Ground Ground Power supply Power Supply In Power Supply Out Pin No 3 pin terminal 5 08 mm grid 3 pin terminal 5 08 mm grid 1 24 V 24 V 2 Ground Ground 3 Shield Shield ...

Page 6: ... red ring is placed on the cable connector in addition to the letter code on the transducer Software tool ConfigTools First steps After connecting the required components to your Ethernet system and checking if the power supply is ensured continue as follows Install the software tool ConfigTools which is to be found on the supplied CD MSX E Systems As soon as you have started the installed softwar...

Page 7: ...X E system The following actions are possible IP Address Change the IP address of the MSX E system in order to adapt it for example to your corporate network Web Interface Access the web interface of your MSX E system and change the configuration Save General Configuration Save the general configuration of the MSX E system including for example the network configuration i e all the settings define...

Page 8: ... the channels to be acquired and start the acquisition with monitoring For each channel each acquired value is immediately displayed in a diagram NOTICE Depending on the Ethernet system a different number of buttons and accordingly different types of actions are available Web interface Quick access to the MSX E system From the web interface of your MSX E system you can access the system quickly an...

Reviews: