100
ADC Telecommunications, Inc.
Table 23. ISDN Alarm Types
Alarms
Value
Description
Default
DSL Loss Of Frame
CR, MJ, MN, NA, NR
Generated if there is a DSL Loss of Frame
MN
DSL Loss Of Signal
CR, MJ, MN, NA, NR
Generated if there is a DSL Loss of Signal
MN
HOURLY ES
CR, MJ, MN, NA, NR
Generated if the accumulated hourly ES count
at the COLU/RTLU reaches or exceeds its
threshold value. A single threshold value is
used for threshold errors in the customer or
network direction.
MN
DAILY ES
CR, MJ, MN, NA, NR
Generated if the accumulated daily ES count at
the COLU/RTLU reaches or exceeds its
threshold value. A single threshold value is
used for threshold errors in the customer or
network direction.
MN
HOURLY SES
CR, MJ, MN, NA, NR
Generated if the accumulated hourly SES
count at the COLU/RTLU reaches or exceeds
its threshold value. A single threshold value is
used for threshold errors in the customer or
network direction.
MN
DAILY SES
CR, MJ, MN, NA, NR
Generated if the accumulated daily SES count
at the COLU/RTLU reaches or exceeds its
threshold value. A single threshold value is
used for threshold errors in the customer or
network direction.
MN
D+ Loss of Frame
CR, MJ, MN, NA, NR
Generated if the ISDN m-channel framing
pattern has been lost on the HDSL link
MN
D+ Loss of Signal
CR, MJ, MN, NA, NR
Generated if the ISDN m-channel loses
synchronization
MN