ADC Telecommunications, Inc.
91
Table 20. HDSL Alarm Types
Alarms
Value
Description
Default
HDSL LOSW
CR, MJ, MN, NA, NR
HDSL Loop has lost synchronization
MJ
HDSL ES 15 MN
CR, MJ, MN, NA, NR
HDSL ES 15 minute alarm is generated if
the current 15 minute HDSL ES count
reaches or exceeds this threshold
MN
HDSL ES 24 HR
CR, MJ, MN, NA, NR
HDSL ES 24 hour alarm is generated if the
HDSL ES 24 hour count reaches or
exceeds this threshold
MN
HDSL UAS 15 MN
CR, MJ, MN, NA, NR
HDSL UAS 15 minute alarm is generated
if the current
15-minute HDSL UAS count reaches or
exceeds this threshold
MN
HDSL UAS 24 HR
CR, MJ, MN, NA, NR
HDSL UAS 24 hour alarm is generated if
the HDSL UAS
24-hour count reaches or exceeds this
threshold
MN
HDSL LOW MARGIN
CR, MJ, MN, NA, NR
HDSL low margin alarm is generated if the
margin is equal to, or less than, this
threshold
MN
HDSL LOOP REVERSAL
CR, MJ, MN, NA, NR
HDSL loops A and B are reversed on the
span
MN
HDSL TIP-RING REVERSAL
CR, MJ, MN, NA, NR
HDSL tip-ring of the HDSL A or B loop is
reversed on the span
NA