![ADC HRU-419 HiGain User Manual Download Page 48](http://html1.mh-extra.com/html/adc/hru-419-higain/hru-419-higain_user-manual_2848162048.webp)
Installation
150-419-100-03>
40
September 25, 1998
HRU-419 List 1
Remote Logoff
Press
from the Remote Terminal Main Menu to log off the system. The
Remote Logoff screen displays indicating that you have logged off the
HRU-419.
Table 13.
Alarm History Fields and Descriptions
Field
Description
Type
Identifies the type of alarm.
LOS,
DS1-HLU
First and last instance of LOS at the HLU; Current condition, number of
alarms.
LOS,
DS1-HRU
First and last instance of LOS at the HRU; Current condition, number of
alarms.
Span 1
LOSW,
HDSL1
First and last instance of LOSW on HDSL1; Current condition, number of
alarms.
Span 1
LOSW,
HDSL2
First and last instance of LOSW on HDSL2; Current condition, number of
alarms.
Span-1 ES,
HDSL1
First and last instance of ES on HDSL1; Current condition, number of
alarms.
Span 1 ES,
HDSL2
First and last instance of ES on HDSL2; Current condition, number of
alarms.
Span 1
Margin L1
First and last instance of exceeded margin on Loop 1; Current condition,
number of alarms.
Span 1
Margin L2
First and last instance of exceeded margin on Loop 2; Current condition,
number of alarms.
PWR Open
Power condition: Open or Closed.
PWR SHRT
Power short condition.
Last Cleared:
None
Last time Alarm History cleared.
H