350-200-115-02, Issue 2
Provisioning
HLU-200 List 1E
September 25, 1998
7
P
ROVISIONING
The HLU-200 List 1E specific user options can only be set from its front
panel RS-232 Craft port. Only one of these options, the DS1 line code (B8ZS
or AMI), is sent to the LITESPAN system manager, which reads the value
and then provisions the LITESPAN Gate Array accordingly. The
HLU-200 List 1E line code setting is not available from OMAPS. It must be
provisioned and read from the RS-232 Craft port.
L
INE
C
IRCUIT
S
ETTINGS
O
PTION
The HLU-200 List 1E supports the following Line Circuit Settings Option:
1
Retrieve Line Circuit Settings (DLP-322) on a slot occupied by a
HLU-200 List 1E:
a
Access ID.
b
AIS (Alarm Indicating Signal). This entry determines the type of
AIS that is sent upstream of the CBA when the HLU-200 List 1E is
in its alarm state. It is permanently set to the all ones state. The None
or All option, normally available in standard Litespan cards, is not
available in the HLU-200 List 1E.
c
Red Lined. A Yes or No indicating a circuit’s Red Lined status. A
circuit cannot have its provisioning changed without first notifying
the customer served by that circuit.
d
Cross Connection Type. Indicates that an AHT1U is cross connected
to another T1 or DS1 line unit.
e
Service State IS or OOS of the unit.
f
Status: Indicate the status of the AHT1U: Cross Connected, OOS,
MT.
2
EDIT T1U Circuit Settings (DLP-323).