Chapter 8 - Internetworking and Management Overview
138
Campus-REX2 RS Interface Card User Manual
Compatibility with Earlier Versions of Campus Products
Campus-RS Desktop and line units are fully compatible with most of the
earlier versions of Campus products, including Campus-E1, Campus-T1, and
Campus-768. The Campus-RS Desktop and line units are not currently
compatible with Campus-384 products.
Furthermore, if a Campus-RS unit is connected over an HDSL link to an
earlier Campus product, and if either unit has the HDSL Transceiver (XCVR)
Mode set to AUTO, the HDSL link may not operate properly.
When operating the Campus-RS product with an earlier version of the
Campus products, to avoid any problems with link startup or operation, it is
recommended that the Transceiver Mode be set as follows:
•
Campus-RS = MASTER
•
Campus E1/T1/768 = SLAVE
If one or both units are already set to AUTO and the HDSL link is active,
disconnect the HDSL link, change the settings as recommended, and
reconnect the link. This will assure the link integrity on any subsequent
startups.
This situation does not apply to a circuit with two Campus-RS
units. You may leave the units set to their default setting of
AUTO, and they will operate properly.
Summary of Contents for Campus-REX2 RS
Page 1: ...CAMPUS REX2 RS INTERFACE CARD VERSION 5 1 USER MANUAL...
Page 12: ...Table of Contents xii Campus REX2 RS Interface Card User Manual...
Page 30: ...Chapter 1 Installing and Accessing the REX2 18 Campus REX2 RS Interface Card User Manual...
Page 76: ...Chapter 3 Configuring the REX2 64 Campus REX2 RS Interface Card User Manual...
Page 108: ...Chapter 6 Managing Software 96 Campus REX2 RS Interface Card User Manual...
Page 164: ...Index 152 Campus REX2 RS Interface Card User Manual...
Page 165: ......