Chapter 7 - Using the LCD for Configuration and Management
Campus-REX2 RS Interface Card User Manual
109
V
IEWING
AND
C
ONFIGURING
A
LARMS
To determine if there is an active alarm condition:
1
Press Escape until
CAMPUS RS I/F: REX2
is displayed.
2
Press Next three times.
ALARM CONFIG & STATUS
is displayed.
3
Press Enter. The LCD displays these Alarm types:
•
Current Alarms HDSL
•
HDSL Link Alarms
Config and Status
•
Local I/F Alarms Config and Status
•
RMT I/F Alarms Config and Status
If a specific indicator does not display, there is no alarm in that area of
the system.
The following sections describe how to view specific alarm information for
the HDSL, local, and remote ports, and how to configure thresholds.
HDSL Alarms
This section describes how to view and configure alarms on the HDSL line.
Viewing Current Alarms
If the
CURRENT ALARMS
display indicates an HDSL alarm, you can
determine the alarm type:
1
From the
CURRENT ALARMS
display, press Next.
HDSL LINK
ALARMS CONFIG & STATUS
is displayed.
2
Press Enter. The current status of three alarms is displayed:
•
LINK
shows whether the HDSL link is on or off
•
ES
shows whether the errored seconds threshold has been exceeded
on the local unit, remote unit, or both
•
MARGIN
shows whether the margin threshold has been exceeded on
the local unit, remote unit, or both
Summary of Contents for Campus-REX2 RS
Page 1: ...CAMPUS REX2 RS INTERFACE CARD VERSION 5 1 USER MANUAL...
Page 12: ...Table of Contents xii Campus REX2 RS Interface Card User Manual...
Page 30: ...Chapter 1 Installing and Accessing the REX2 18 Campus REX2 RS Interface Card User Manual...
Page 76: ...Chapter 3 Configuring the REX2 64 Campus REX2 RS Interface Card User Manual...
Page 108: ...Chapter 6 Managing Software 96 Campus REX2 RS Interface Card User Manual...
Page 164: ...Index 152 Campus REX2 RS Interface Card User Manual...
Page 165: ......